8
Programming instruction
Refer to the next page, the steps of programming are:
1.
Scan the SETUP bar code on the parameter setting part.
2.
Enter the option mode by scanning the Option bar code.
3.
To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these
alphanumeric entries.
4.
Scan the END bar code, listed on the lower right hand corner of each parameter setting part.
5.
Notes that only one parameter can be setup at each time.
6.
During the process of programming, LED is lighting to indicate the programming correctness. LED
will go off if any incorrect programming operation performed.
7.
After each successful programming, LED will go off and the scanner will beep twice.
8.
Throughout the programming bar code menus, the factory default settings are indicated with
asterisks (*).
Example: to set Flow control to be XON/XOFF.
Steps: Scan the following barcodes in order.
SETUP
Option bar code
Option
Alpha.
entry
Flow control
None
RTS/CTS
(Host: Low RTS)
RTS/CTS
(Host: High RTS)
XON/XOFF
ACK/NAK
00*
01
02
03
04
Inter-character delay
00-99 (ms)
00-99
00*
Block trans. delay
00-99 (10 ms)
00-99
00*
Response delay
00-99 (100 ms)
00-99
00*
END
Figure 7
SETUP bar code
Alpha. entries
Option bar code
END bar code
Содержание RA1001 Series
Страница 1: ...RA1001 Series Barcode Scanner User Manual Version MD_UM_EN_V3 1 5R...
Страница 7: ...3 Decode zone High Density series Long Range series...
Страница 8: ...4 Dimensions...
Страница 59: ...55 Configuration alphanumeric entry barcode...