3 Installation of the RLED45CC1
Installation should only be carried out by a competent electrician.
DO NOT CONNECT DIRECTLY TO THE MAINS SUPPLY.
●
All LED fittings should be wired in
series.
●
RLED45CC1 modules should be mounted in areas that are adequately ventilated,
dry, and outside of any enclosed metal casings that may interfere with the Wireless
signal.
●
Modules should be mounted vertically, with the terminals at the bottom, or
horizontally.
●
While the modules are designed to be maintenance-free, they should be mounted
in an accessible location should investigation or re-addressing of the units be
necessary.
●
Ensure that the cable clamps are fitted tightly to secure the cables.
STEP 1
Remove the covers and cable
clamps.
STEP 2
Select the Constant Current
output on the RLED45CC1 to
match the rating on the load.
●
1000mA
●
700mA
●
600mA
●
500mA
●
350mA
NB
Do not set multiple jumpers.
RLED45CC1
Manual Version 2.0.0