Problem
Resolution
●
Ensure that the wireless client’s IP address
settings are configured properly.
●
Ensure that the security settings on the client
device and BreadCrumb devices match.
●
Ensure that the client device is not prevented
from connecting by an ACL.
●
Ensure that the VLAN settings for the
BreadCrumb allow clients of the ESSID
being used to communicate to the Local Port
of the BreadCrumb. See the VLAN section
of the BC|Commander manual for more
information.
6.2 BreadCrumb Device Cannot Connect to BCWN
Table 10: BreadCrumb to BCWN Connectivity Issues.
Problem
Resolution
Discharged batteries can cause the BreadCrumb
device to appear to power up, but not be able to
establish connectivity to the BCWN.
When deploying the BCWN, ensure that the
batteries are fully charged.
When using external antennas, faulty cable
connections or crimped cables can result in
difficulty establishing and maintaining network
connectivity.
Check antenna cables and their connections to
the BreadCrumb device.
6.3 BreadCrumb Power and Start-Up Issues
Table 11: BreadCrumb Power and Start-Up Issues.
Problem
Resolution
Discharged external batteries can cause a
BreadCrumb to appear to power up(“PWR”
Monitory battery usage and charge/replace
26