Raisecom
RCMS2902-2E1GE-BL Product Description
3 Card appearance and descriptions
Raisecom Technology Co., Ltd.
8
LED
Status
Description
LOS
Red
Loss Of Signal (LOS) alarm LED
Red: optical signals received by the local optical interface are
lost.
Blinking red: optical signals received by the remote optical
interface are lost.
Off: optical signals received by the optical interface are
normal.
Gb
Green
Ethernet interface working mode LED
Green: the device is working in 1000 Mbit/s mode.
Off: the device is working in 100 Mbit/s mode or stops
working.
LNK/ACT
Green
Ethernet interface working LED
Green: the Ethernet interface is connected properly.
Blinking green: the Ethernet interface is properly connected
is receiving or sending data.
Off: the Ethernet interface is connected improperly.
1000M
Green
Ethernet interface working speed LED
Green: the Ethernet interface speed is 1000 Mbit/s.
Off: the Ethernet interface speed is 100 Mbit/s or the Ethernet
interface is not working.
L/R
LOS(1-2)
Red
E1 tributary Rx signal LOS alarm LED
Red: a LOS alarm is generated on the local E1 tributary.
Blinking red: a LOS alarm is generated on the remote E1
tributary.
Off: no LOS alarm is generated on the local and remote E1
tributaries.
When an alarm is generated on both the local and remote devices, the alarm on
the local device is displayed first.
Only in E1 framed mode, the alarm on the remote device can be displayed on the
local device.
3.3 Interfaces
Table 3-2 describes interfaces on the RCMS2902-2E1GE-BL.
Table 3-2
Interfaces on the RCMS2902-2E1GE-BL
Interface
Type
Description
GE
RJ45
One GE Ethernet electrical interface
2E1
RJ45
One E1 balanced interface for transmitting 2-way balanced
E1 services