![Raisecom RC953-GESTM1 Скачать руководство пользователя страница 195](http://html.mh-extra.com/html/raisecom/rc953-gestm1/rc953-gestm1_command-manual_782829195.webp)
www.raisecom.com
User Manual
184
Chapter 37
The configuration command under fxInterface configuration mode
of remote RC954-FX4E1.
37.1 flow-control
[Command Format]
flow-control {on|off}
[Function]
The flow control is on or off.
[Parameter]
N/A
[Default]
The flow control is off.
[Command mode]
Remote protocalEthInterface configuration mode.
[Application Example]
RC953-GESTM1
#
config
RC953-GESTM1(config)
#
remote ric 1
RC953-GESTM1(config-RC954FX4E1/1)
#
interface
fx-eth
RC953-GESTM1(config-RC954FX4E1/1-fxeth/1)
#
flow-control on
Set successfully.
37.2 interface e1
[Command Format]
interface e1
<1-4>
[Function]
Enter interface configuration mode.
[Default]
N/A
[Command mode]
Remote protocol configuration mode, remote protocalE1 or Eth interface mode.
[Application Example]
RC953-GESTM1(config-RC954FX4E1/1-fxeth/1)
#
interface e1 4