Raisecom RC802-60B Series Скачать руководство пользователя страница 10

                                                          

Raisecom Technology Co., Ltd 

5.  Installation and Test 

5.1. Inspecting the Product 

Before installation, please first check the models and quantities of optical multiplexers and 
accessories with the packing list. Also, please check whether the equipment is in perfect 
condition. Occasionally, drying process may be needed if the equipment is affected with 
damp environment. 

5.2. Preparation Before Installation                                                                                       

The following steps are required before installing the optical multiplexers: 

‹

  Please read the user manual carefully. 

‹

  Prepare all the wires and cables that are needed. Make sure there is no reverse 

connection, disconnection or short circuit connection. Refer to Appendix A for 
details of cable making. 

‹

  Make sure that the voltage of the power supply is within the tolerance range and the 

chassis is grounded with the earth. 

‹

  Prepare the bit-error-rate tester and optical power test-meter for the test of link 

quality. 

‹

  If using 120

 balanced signal interface, please change the dip-switch setup on the 

bottom of the optical multiplexer. 

‹

  Fix the optical multiplexer into RC001-16 (19-inch 3U chassis). Pay attention to the 

ambience requirement. 

5.3. Installation 

5.3.1.  Connecting Data Interfaces 

z

 E1 

interface 

It is suggested to use cables provided in accessories. 
 

z

 Optical 

interface 

Insert the SC fiber tail into the optical interface (push hard until to the end). If you are not 
sure about transmission direction, it’s advised to connect the fiber cable after applying the 
power supply. 

5.3.2. Applying Power Supply 

Insert the module into the chassis and fix it with the screw at the bottom of the module. 
 
If the power supply is DC –48V, please ground the PGND with the earth first, then “-48V” 
pin with the lower voltage cable, “0V” pin with higher voltage cable before applying the 
power supply. Make sure it is firmly fixed, and there’s no reverse connection and no short 
circuit before applying the power supply. 

Содержание RC802-60B Series

Страница 1: ...RC802 60B RC804 60B RC806 60B Dual E1s link Modular Optical Multiplexer User Manual Rev M Raisecom Technology Co Ltd 12 2004 ...

Страница 2: ...integrated device that has precise elements please avoid violent shakes and impacts and do not disassemble or maintain the device yourself If it is required please do it under the guide of our technical staff following in the steps of anti static Please contact us if there is any need There must be grounding protection for the sake of safety do not disassemble the device yourself we regard it as y...

Страница 3: ...ront Panel 6 4 1 1 Power Supply Indicator 6 4 1 2 Alarm Indicators 6 4 1 3 E1 Interface 6 4 1 4 Optical Interface 7 4 2 Dip switch Setup 7 4 2 1 Dip switch SW5 Setup 7 4 2 2 E1 Interface Impedance Setup SW4 8 4 2 3 Factory Default setup SW3 8 5 Installation and Test 9 5 1 Inspecting the Product 9 5 2 Preparation Before Installation 9 5 3 Installation 9 5 3 1 Connecting Data Interfaces 9 5 3 2 Appl...

Страница 4: ... loop back function for E1 channel It is convenient for deployment operation and maintenance z RC800 60B is also featured by modularization design with high security stability reliability and easy to use Power supply is provided from the chassis backplane 2 3 Product Article Description Article Description RC802 60B S1 Module at central office customer premise DB9 interfaces for 2 E1 channel optic...

Страница 5: ... Ltd 4 The following products can work in pairs Central office module Customer premises module RC802 60B S1 RC802 60B S1 RC802 60B S2 RC802 60B S2 RC802 60B S3 RC802 60B S3 RC806 60B S1 RC804 60B S1 RC806 60B S2 RC804 60B S2 ...

Страница 6: ...or some types Product number Optical interface Transmit Wavelength Nm Launch power dBmW Receiving sensitivity dBmW Over load point dBm Typical transmission distance Km Optical loss dB Km RC802 60B S1 DSC 1310 15 8 34 8 0 25 0 5 RC802 60B S2 DSC 1310 5 0 34 8 10 60 0 5 RC802 60B S3 DSC 1550 DFB 5 0 36 10 15 120 0 25 RC804 60B S1 SC PC 1310 12 3 30 8 0 25 0 5 RC804 60B S2 SC PC 1310 5 0 32 8 10 50 0...

Страница 7: ...rm in optical link red ON when the receiving signal loss occurs at the local site Flashing when the receiving signal loss occurs at the remote site LERR receiving signal error alarm in optical link yellow ON when LOF loss of frame alignment occurs or the receiving BER exceeds 10 3 level at local site RERR receiving signal error alarm in optical link yellow ON when LOF loss of frame alignment occur...

Страница 8: ...ack is set up on local optical multiplexer the remote optical multiplexer will generate internal loop and external loop simultaneously z 4th bit Fault Pass Through FPT function setup When FPT is disabled it is identical to the AIS function of traditional optical multiplexers When the receiving signals of the E1 interface at the remote site are lost the CORRESPONDING local E1 interface will output ...

Страница 9: ...d by the remote multiplexer the module need to be manually set up to that working mode 4th bit Remote management setup OFF Auto sensing management setup ON Forced management by the remote site multiplexer 4 2 2 E1 Interface Impedance Setup SW4 Please use a small flat blade screwdriver or other sharp end tools to set up the dip switch Each group of dip switch is corresponding to its respective E1 i...

Страница 10: ...e tester and optical power test meter for the test of link quality If using 120Ω balanced signal interface please change the dip switch setup on the bottom of the optical multiplexer Fix the optical multiplexer into RC001 16 19 inch 3U chassis Pay attention to the ambience requirement 5 3 Installation 5 3 1 Connecting Data Interfaces z E1 interface It is suggested to use cables provided in accesso...

Страница 11: ...Raisecom Technology Co Ltd 10 If the power supply is AC 220V please use the power cable in the accessories provided by the factory After applying the power supply the PWR indicator shall be steadily ON ...

Страница 12: ...y connected And check the receiving optical power with optical power test meter which shall be bigger than the index of receiving sensitivity z Yellow ERR indicator of optical port is on Answer The loss of frame alignment occurs or the bit error rate of optical RX signal is greater than 10 6 or 10 3 Usually ERR alarm occurs right after applying the power supply but after 10 seconds the ERR indicat...

Страница 13: ... of Cable Making E1 Cable Making RC800 60B series E1 cable Please order cables from factory 2005 Raisecom Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification ...