iTN2100 (P100R002) Hardware Description
13 EOP cards
Raisecom Technology Co., Ltd.
106
LED
Status
Description
SYS
Green
System status LED
Green: the system is working improperly.
Off: the system is working improperly.
Blinking green: the system is working properly.
ALM
(1–8)
Red
Overall alarm LED
Red: the LOS, LOF, AIS, or CRC_ERR alarm is
generated on the local device.
Blinking red: the LOS, LOF, AIS, or CRC_ERR alarm is
generated on the remote device.
Off: no LOS, LOF, AIS, or CRC_ERR alarm is generated
on the local and remote devices.
LOS
(1–8)
Red
LOS alarm LED
Red: local E1 LOS alarms are generated.
Off: no local E1 LOS alarms are generated.
13.7.5 Alarms
Table 13-34 lists alarms generated on the OPCOM3500E-EOPS-8E1.
Table 13-34
Alarms generated on the OPCOM3500E-EOPS-8E1
Alarm
Cause
Level
E1 AIS
E1 signals are all 1 because the transmitted data is
incorrect or the remote device outputs AIS
signals.
Minor
E1 LOF
Data sent by the upstream node is incorrect,
because services are configured improperly or the
hardware fails.
Critical
E1 CRC
An Error on data during transmission.
Critical
TU-AIS
Signals from the aggregation card fails.
Minor
13.7.6 Cables
Table 13-35 lists cables available for the OPCOM3500E-EOPS-8E1.
Table 13-35
Cables available for the OPCOM3500E-EOPS-8E1
Card
Recommended cable
OPCOM3500E-EOPS-8E1
CBL-E1-DB37F (40)/16NC
CBL-E1-DB37F/16BNCF
CBL-E1-DB37F/16BNCM
OPCOM3500E-EOPS-8E1-BL
CBL-E1-DB37F/8RJ45