Raisecom 
ISCOM5504-GP (A) Hardware Description 

3 Fiber and cables 

 

 

Raisecom Proprietary and Confidential 

Copyright © Raisecom Technology Co., Ltd. 

18 

 

Figure 3-1

 

LC/PC fiber connector 

 

When connecting or removing the LC/PC fiber connector, align the connector with the optical 
interface, and do not rotate the fiber. Operate the fiber as below: 

 

To connect the fiber, align the head of the fiber with the optical interface and insert the 
fiber into the interface gently. 

 

To remove the fiber, press down the clamping connector, and push the fiber head 
inwards, and then pull the fiber out. 

SC/PC fiber connector 

Figure 3-2 shows the appearance of the SC/PC fiber connector. 

Figure 3-2

 

SC/PC fiber connector 

 

When connecting or removing the SC/PC fiber connector, align the connector with the optical 
interface, and do not rotate the fiber. Operate as below: 

 

To connect the fiber, align the head of the fiber with the optical interface and insert the 
fiber into the interface gently. 

 

To remove the fiber, push the fiber head slightly inwards, and then pull the fiber out. 

FC/PC fiber connector 

Figure 3-3 shows the appearance of the FC/PC fiber connector. 

Содержание ISCOM5504-GP

Страница 1: ...ISCOM5504 GP A Hardware Description Rel_01 www raisecom com...

Страница 2: ...may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in Writing from Raisecom Technology Co L...

Страница 3: ...ted to the ISCOM5504 GP Name Description ISCOM5504 GP A Hardware Description This document introduces the hardware structure and cards including product overview components fiber and cables pluggable...

Страница 4: ...enarios installation conditions and installation steps Conventions Symbol conventions The symbols that may be found in this document are defined as follows Symbol Description Indicate a hazard with a...

Страница 5: ...echnology Co Ltd 3 Convention Description Book Antiqua Heading 1 Heading 2 Heading 3 and Block are in Book Antiqua Change history Updates between document versions are cumulative Therefore the latest...

Страница 6: ...ponents 5 2 1 3 Hardware information label 6 2 2 Main control switching card GPSC 7 2 2 1 Introduction 7 2 2 2 Panel and slots 7 2 2 3 Interfaces 7 2 2 4 LEDs 9 2 2 5 Technical specifications 10 2 3 A...

Страница 7: ...arance 24 3 4 3 Technical specifications 24 3 5 AC power cable 25 3 5 1 Introduction 25 3 5 2 Appearance 25 3 5 3 Technical specifications 26 3 6 Ground cable 27 3 6 1 Introduction 27 3 6 2 Appearance...

Страница 8: ...Raisecom ISCOM5504 GP A Hardware Description Contents Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd 6 7 Appendix 38 7 1 Terms 38 7 2 Acronyms and abbreviations 39...

Страница 9: ...of the RPA1101 power module 11 Figure 2 7 Panel of the RPD1101 power module 12 Figure 2 8 Panel of the FANS306 module 14 Figure 3 1 LC PC fiber connector 18 Figure 3 2 SC PC fiber connector 18 Figure...

Страница 10: ...Raisecom ISCOM5504 GP A Hardware Description Figures Raisecom Proprietary and Confidential Copyright Raisecom Technology Co Ltd 8 Figure 4 4 PON SFP optical module 33...

Страница 11: ...wer module 11 Table 2 10 LEDs on the RPA1101 power module 11 Table 2 11 Technical specifications of the RPA1101 power module 12 Table 2 12 Interface on the RPD1101 power module 13 Table 2 13 LEDs on t...

Страница 12: ...the OT terminal 28 Table 4 1 Model of the 1000 Mbit s SFP optical module 31 Table 4 2 Technical specifications of the 1000BASE X SFP optical interface 31 Table 4 3 Technical specifications of the 100...

Страница 13: ...low density and long distance requirements for optical fiber access Act as an OLT in GPON and work with the Optical Network Unit ONU Meet Fiber to The Home FTTH and Fiber to The Building FTTB network...

Страница 14: ...e to be deployed Dimensions of the chassis are 440 mm Width 266 mm Depth 44 mm Height without brackets Figure 1 1 shows the appearance of the ISCOM5504 GP chassis Figure 1 1 Appearance of the ISCOM550...

Страница 15: ...1 1 Physical parameters of the ISCOM5504 GP Parameter Description Dimensions 440 mm Width 266 mm Depth 44 mm Height without brackets Weight DC 5 0 kg AC 5 3 kg Maximum power consumption DC 41 W AC 44...

Страница 16: ...A1101 SI 220S12 DC power module RPD1101 48S12 Fan module FANS306 2 1 Overview 2 1 1 Classification of components The ISCOM5504 GP is composed of the following four types of components Main control swi...

Страница 17: ...pearance of main control switching card Figure 2 1 shows the appearance of the main control switching card GPSC Figure 2 1 Appearance of the main control switching card GPSC Appearance of power module...

Страница 18: ...chnology Co Ltd 6 Figure 2 3 Appearance of the fan module 2 1 3 Hardware information label Hardware information of ISCOM5504 GP components will be described by a label pasted on the Printed Circuit Bo...

Страница 19: ...Main control switching card GPSC 2 2 1 Introduction The GPSC card is the main unit for accessing processing and switching services It provides 4 GPON optical interfaces 2 GE electrical interfaces RJ4...

Страница 20: ...cal module type 10GBASE LX SX PON 1 2 3 4 PON SFP GPON service interface Supported optical module type Class B or Class C Table 2 4 lists parameters of the Console interface Table 2 4 Parameters of th...

Страница 21: ...s Description PWR Green Power LED Green the power supply is working properly Off the power supply is working improperly SYS Green System working LED Fast blinking green 4 Hz the system is initializing...

Страница 22: ...consumption 34 5 W 2 3 AC power module RPA1101 SI 220S12 2 3 1 Introduction The RPA1101 SI 220S12 hereinafter referred to as RPA1101 module is the AC power module of the ISCOM5504 GP It supports the f...

Страница 23: ...socket 2 3 4 LEDs There are 3 LEDs on the RPA1101 power module Table 2 10 lists LEDs on the RPA1101 power module Table 2 10 LEDs on the RPA1101 power module LED Status Description PWR Green Power LED...

Страница 24: ...erential mode 1 kV Common mode 2 kV 2 4 DC power module RPD1101 48S12 2 4 1 Introduction The RPD1101 48S12 hereinafter referred to as RPD1101 module is the DC power module of the ISCOM5504 GP It suppo...

Страница 25: ...RPD1101 power module LED Status Description PWR Green Power LED Green the power supply is working properly Off the power supply is working improperly DC Green Power input LED Green the input power is...

Страница 26: ...n and an alarm is generated when the fan fails Support adjusting the rotational speed of the fan manually or automatically Support hot swapping 2 5 2 Panel and slots The FANS306 module can be inserted...

Страница 27: ...rm LED Red the module is working improperly and an alarm is generated Off the module is working properly 2 5 4 Technical specifications Table 2 16 lists technical specifications of the FANS306 module...

Страница 28: ...two kinds of fiber are different in color The yellow one is single mode fiber and the orange one is the multi mode fiber The ISCOM5504 GP can be connected to the Optical Distribution Frame ODF or opti...

Страница 29: ...ble for the optical interface Otherwise it may increase additional loss of fiber links reduce transmission quality of services or even damage the connector and optical interface 3 1 2 Connector Fiber...

Страница 30: ...ove the fiber press down the clamping connector and push the fiber head inwards and then pull the fiber out SC PC fiber connector Figure 3 2 shows the appearance of the SC PC fiber connector Figure 3...

Страница 31: ...leeve clockwise to secure the optical interface To remove the fiber rotate the screw sleeve counterclockwise When the screw sleeve is loosened pull the fiber out 3 1 3 Wiring Table 3 3 lists the wirin...

Страница 32: ...hrough cable both two RJ45 connectors of the straight through cable follow EIA TIA 568B wiring Crossover cable one RJ45 connector of the crossover cable follows EIA TIA 568A wiring the other RJ45 conn...

Страница 33: ...N definitions of the crossover cable Table 3 5 PIN definitions of the crossover cable Connector 1 RJ45 EIA TIA568A Connector 2 RJ45 EIA TIA568B PIN 1 White Green PIN 1 White Orange PIN 2 Green PIN 2 O...

Страница 34: ...gth which can be customized For example if the customer requires 2 meter cables they are named CBL ETH RJ45 RJ45 2m RoHS 3 3 Configuration cable The configuration cable is used to connect the Console...

Страница 35: ...Figure 3 7 Configuration cable 3 3 2 Wiring Figure 3 8 shows the PINs and wiring of the RS 232 serial interface and RJ45 Ethernet interface Figure 3 8 PINs and wiring Table 3 7 lists PINs of the RS 23...

Страница 36: ...r souring equipment to the power interface on the RPD0601 module of the ISCOM5504 GP and then transmits power to the entire device 3 4 2 Appearance The DC power cable is composed of the DC power conne...

Страница 37: ...504 GP and then transmits power to the entire device Types of the AC power cable of the ISCOM5504 GP depend on different regional standards as shown in Table 3 10 Table 3 10 AC power cable Regional st...

Страница 38: ...m2 Length The letter D indicates the length which can be customized For example if the customer requires 1 5 meter cables they are named POL AC European 3 pin C13 connector 0 75 mm2 1 5 m RoHS Table 3...

Страница 39: ...used 3 6 1 Introduction The ground cable is used to ground the ISCOM5504 GP 3 6 2 Appearance The ground cable is composed of the ground terminal and conductive wire In general ground terminals are OT...

Страница 40: ...shrink tubing which is a 20 mm plastic tube and shrinks when heated Welding technology The conducting wire and OT terminals adopt solderless pressed connection Error in length of conducting wire 5 mm...

Страница 41: ...ry and Confidential Copyright Raisecom Technology Co Ltd 29 The ISCOM5504 GP is delivered without the ground cable If required prepare or make ground cables on site The ground cable cannot be longer t...

Страница 42: ...Gbit s SFP optical module PON SFP optical module 4 1 1000 Mbit s SFP optical module 4 1 1 Functions and appearance The 1000 Mbit s Small Form factor Pluggables SFP optical module is applicable to the...

Страница 43: ...5 km S1 15 km S2 40 km S3 80 km D Support DDM 01 Internal identifier different values of which indicate the same function R Comply with RoHS 1310nm Tx wavelength 1310 nm SM Single mode fiber DDM Suppo...

Страница 44: ...FP Gb S1 D R 1310 LC PC Dual fiber single mode 10 to 3 3 9 21 15 USFP Gb S2 D R 1550 LC PC Dual fiber single mode 3 to 2 3 9 21 40 USFP Gb S3 D R 1550 LC PC Dual fiber single mode 3 to 2 9 9 30 80 4 2...

Страница 45: ...fications of the SFP optical module Model Tx wavelength nm Laser type Rx laser Tx optical power dBm Min overload point dBm Extinction ratio dB Rx sensitivity dBm Transmiss ion distance km USFP 192 M 8...

Страница 46: ...ance 20 km Fiber mode SMF Central wavelength Laser type Tx 1490 nm DFB Rx 1310 nm APD TIA Tx optical power 1 5 5 dBm Extinction ratio 8 2 dB Rx sensitivity 28 dBm Minimum overload point 8 dBm Table 4...

Страница 47: ...en the interface is connected properly Blinking green the interface is transmitting data Off the interface is disconnected or connected improperly LINK ACT 1 2 RJ45 electrical interface integrated LED...

Страница 48: ...cription ALM Red Power alarm LED Red the power is working improperly and an alarm is generated Off the power is working properly AC Green AC power working LED Green the power module is working properl...

Страница 49: ...the ISCOM5504 GP Table 6 1 Weight and power consumption of the ISCOM5504 GP Component Description Weight DC 5 0 kg AC 5 3 kg Maximum power consumption DC 41 W AC 44 W GPSC Weight 0 64 kg Power consum...

Страница 50: ...rms 1U Unit of dimension short for unit It takes 44 45 mm as basic unit namely 1 U 44 45 mm B Bracket Small parts at the side of chassis being used to install the chassis into the cabinet E ETSI 600 c...

Страница 51: ...her cause fire nor generate harmful radiation under normal conditions M Multi mode fiber In this fiber multi mode optical signals are transmitted P PWE3 Pseudo Wire Emulation Edge to Edge R RS232 In s...

Страница 52: ...c Discharge ETSI European Telecommunications Standards Institute L LLDP Link Layer Discovery Protocol M MPLS Multi protocol label switching O ODF Optical Distribution Frame OAM Operation Administratio...

Страница 53: ...Address No 11 East Area No 10 Block East Xibeiwang Rd Haidian District Beijing P R China Postal code 100094 Tel 86 10 58963399 Fax 8610 58963399 8886 http www raisecom com Email export raisecom com...

Отзывы: