Raisecom ISCOM3012GF Скачать руководство пользователя страница 7

www.raisecom.com                                                                                                                                     

 User Manual

 

 

2           

be present inside certain products even when the power switch (if installed) is in the OFF position or 
a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, 
energy hazards may still exist. 
Before working on equipment connected to power lines or telecommunication lines, remove jewelry 
or any other metallic object that may come into contact with energized parts. 
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding 
is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth 
lug is provided on the product, it should be connected to the protective earth at all times, by a wire 
with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed 
racks and cabinets. 
Always make the ground connection first and disconnect it last. Do not connect telecommunication 
cables to ungrounded equipment. Make sure that all other cables are disconnected before 
disconnecting the ground. 

Connection of AC Mains 

Make sure that the electrical installation complies with local codes. 
Always connect the AC plug to a wall socket with a protective ground. 
Always connect the power cord first to the equipment and then to the wall socket. If a power switch 
is provided in the equipment, set it to the OFF position. If the power cord cannot be readily 
disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency 
switch is installed in the building installation. 

Connection of DC Mains 

Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to 
the ground. Any single pole can be externally grounded. 
Due to the high current capability of DC mains systems, care should be taken when connecting the 
DC supply to avoid short-circuits and fire hazards. 
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to 
qualified service and maintenance personnel. 
Make sure that the DC supply is electrically isolated from any AC source and that the installation 
complies with the local codes. 
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate 
the circuit breaker of the panel board that services the equipment and switch it to the OFF position. 
When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, 
then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. 
A readily accessible disconnect device that is suitably rated and approved should be incorporated in 
the building installation. 

Preventing Electrostatic Discharge Damage 

Modules which can be plugged into chassis are sensitive to damage from static electricity. 
Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam 
packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper 
electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. 
To minimize the potential for ESD damage, observe the following guidelines: 
• Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good 
skin contact. 
• When removing or installing a component, make sure the equipment end of your antistatic strap 
leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal 
surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only 
protects the component from ESD voltages on the body; ESD voltages on your clothing can still 
cause component damage. 
• Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a 
static shielding bag. If you are returning the item to the factory, immediately place it in a static 
shielding bag. 
• Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector 
pins. 

Содержание ISCOM3012GF

Страница 1: ...www raisecom com ISCOM3012GF Hardware Installation User Manual...

Страница 2: ...ge without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2007 Raisecom All rights r...

Страница 3: ...10 82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the I...

Страница 4: ...ce Appearance 5 3 1 Device front panel description 5 3 2 Device rear panel description 6 Chapter 4 Installation and Application 8 4 1 Device model 8 4 2 Device installation 8 4 2 1 Environment require...

Страница 5: ...nd other relevant reference documents and explains relevant term definitions Chapter 2 Specifications and Dimension This chapter is an instruction of the device specifications device dimension and dev...

Страница 6: ...t the fiber optic cable is intact and is connected to the transmitter Do not attempt to adjust the laser drive current Do not use broken or unterminated fiber optic cables connectors or look straight...

Страница 7: ...stalled in a restricted access area i e an area where access is authorized only to qualified service and maintenance personnel Make sure that the DC supply is electrically isolated from any AC source...

Страница 8: ...running at 100Mbps 1000BASE X A term in IEEE 802 3 for Gigabit Ethernet over fiber based on 8B 10B coding and running at 1000Mbps Auto Negotiation The auto negotiation procedure is the port at one sit...

Страница 9: ...4 combo interfaces in support of both 1000BASE X in the form of SFP and 10 100 1000BASE T in the form of RJ 45 The power consumption of the system is less than 30W 2 2 Device dimension The dimension o...

Страница 10: ...rder SYS Green Other Status Software fault or the system is initializing after electrifying ON The power supply module on the left is electrified PWR1 Green OFF The power supply module on the left is...

Страница 11: ...or Status Description ON The electrical port is in Link Up status Flickering The electrical port is transmitting or receiving data LNK ACT Green OFF The electrical port is in Link Down status ON The e...

Страница 12: ...www raisecom com User Manual 7 Device grounding terminal...

Страница 13: ...nto a rack please fix the installation tray to the switch using the four screws come with the device and fasten the installation handle on to the rack 4 2 3 Grounding To ensure the safety of the devic...

Страница 14: ...1 2 7 8 N C 2 PC serial port signal definition The pin number and pin function definition of 9 pin serial port connector is shown in the figure and table below Pin Number Function Type Pin Number Fun...

Страница 15: ...cessfully regardless of the type of interface MDI or MDIX the opposite site of the connection adopts or the type of cable straight through or crossover applied For RJ 45 the definition of MDI and MDIX...

Страница 16: ...he straight through cable for 100M or 1000M are identical Side 1 1 1 Side 2 Side 1 Side 2 3 5 7 4 6 2 8 3 5 7 4 6 2 8 1 White Orange 7 White Brown 1 White Orange 2 Orange 3 White Green 4 Blue 5 White...

Страница 17: ...is working The switch will begin its self check and initialization in succession All the indicators on the front panel of the switch will turn ON during this procedure The switch will be in operating...

Страница 18: ...w humidify may lead to fire alarm In a word the switch must be placed in proper surroundings The power supply of the device should be well earthed to let out the static electricity Please keep some sp...

Страница 19: ...ess 2nd Floor South Building of Rainbow Plaza No 11 Shangdi Information Road Haidian District Beijing Postcode 100085 Tel 86 10 82883305 Fax 86 10 82883056 Email export raisecom com http www raisecom...