be present inside certain products even when the power switch (if installed) is in the OFF position or 
a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, 
energy hazards may still exist. 
Before working on equipment connected to power lines or telecommunication lines, remove jewelry 
or any other metallic object that may come into contact with energized parts. 
Unless otherwise specified, all products are intended to be grounded during normal use. Grounding 
is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth 
lug is provided on the product, it should be connected to the protective earth at all times, by a wire 
with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed 
racks and cabinets. 
Always make the ground connection first and disconnect it last. Do not connect telecommunication 
cables to ungrounded equipment. Make sure that all other cables are disconnected before 
disconnecting the ground. 

Connection of AC Mains 

Make sure that the electrical installation complies with local codes. 
Always connect the AC plug to a wall socket with a protective ground. 
Always connect the power cord first to the equipment and then to the wall socket. If a power switch 
is provided in the equipment, set it to the OFF position. If the power cord cannot be readily 
disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency 
switch is installed in the building installation. 

Connection of DC Mains 

Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to 
the ground. Any single pole can be externally grounded. 
Due to the high current capability of DC mains systems, care should be taken when connecting the 
DC supply to avoid short-circuits and fire hazards. 
DC units should be installed in a restricted access area, i.e. an area where access is authorized only to 
qualified service and maintenance personnel. 
Make sure that the DC supply is electrically isolated from any AC source and that the installation 
complies with the local codes. 
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate 
the circuit breaker of the panel board that services the equipment and switch it to the OFF position. 
When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, 
then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. 
A readily accessible disconnect device that is suitably rated and approved should be incorporated in 
the building installation. 

Preventing Electrostatic Discharge Damage 

Modules which can be plugged into chassis are sensitive to damage from static electricity. 
Conversely, static voltages as high as 35,000V can be generated just by handling plastic or foam 
packing material, or by sliding assemblies across plastic and carpets. Not exercising the proper 
electrostatic discharge (ESD) precautions can result in intermittent or complete component failures. 
To minimize the potential for ESD damage, observe the following guidelines: 
• Always use an ESD-preventive antistatic wrist strap or ankle strap and ensure that it makes good 
skin contact. 
• When removing or installing a component, make sure the equipment end of your antistatic strap 
leash is connected to the ESD connection sockets on the front of the chassis or to a bare metal 
surface on the chassis. Avoid contact between the component and your clothing. The wrist strap only 
protects the component from ESD voltages on the body; ESD voltages on your clothing can still 
cause component damage. 
• Always place a card component-side-up on an antistatic surface, in an antistatic card rack, or in a 
static shielding bag. If you are returning the item to the factory, immediately place it in a static 
shielding bag. 
• Handle Modules by the metal card carrier edges only; Avoid touching the board or any connector 
pins. 

Содержание ISCOM2008

Страница 1: ...www raisecom com ISCOM2008 Hardware Installation User Manual ...

Страница 2: ...age without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2007 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in ...

Страница 3: ...86 10 82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the ISCOM2008 device works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom com en xcontactus con...

Страница 4: ...evice Appearance 5 3 1 Device front panel description 5 3 2 Device rear panel description 6 Chapter 4 Installation and Application 7 4 1 Device model 7 4 2 Device installation 7 4 2 1 Environment requirement 7 4 2 2 Install the device on to a rack 7 4 2 3 Grounding 7 4 3 The connection of the switch 7 4 3 1 Connect to console 7 4 3 2 Connect to Ethernet 9 4 3 3 Connect to the power supply 9 4 4 Ca...

Страница 5: ...content of the manual and explains relevant term definitions Chapter 2 Specifications and Dimension This chapter is an instruction of the device specifications device dimension and device operating environment Chapter 3 Device Appearance This chapter describes the panel of the device and the definition of the indicators on the device panel Chapter 4 Installation and Application This chapter introd...

Страница 6: ...at the fiber optic cable is intact and is connected to the transmitter Do not attempt to adjust the laser drive current Do not use broken or unterminated fiber optic cables connectors or look straight at the laser beam The use of optical devices with the equipment will increase eye hazard Use of controls adjustments or performing procedures other than those specified herein may result in hazardous...

Страница 7: ...nstalled in a restricted access area i e an area where access is authorized only to qualified service and maintenance personnel Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes Before connecting the DC supply wires ensure that power is removed from the DC circuit Locate the circuit breaker of the panel board that servi...

Страница 8: ...er based on 4B 5B coding and running at 100Mbps Auto Negotiation The auto negotiation procedure is the port at one site adapts its bit rate and duplex mode to the highest level it and the opposite site device both support according to the bit rate and duplex mode adopted by the remote site device that is the connected devices on both site adopt the fastest transmission mode they both support after...

Страница 9: ...008 has 1 CONSOLE interface and 8 100BASE TX Ethernet electrical interfaces The power consumption of the system is less than 10W 2 2 Device dimension The dimension of ISCOM2008 switch s main structure is 43 6mm Height x 260mm Width x 130mm Depth The device weighs 1 0kg and can be placed on a table 2 3 Device operating environment Environment temperature 10 C 45 C Storage temperature 40 C 60 C Envi...

Страница 10: ...Flickering The system is operating in order SYS Green Other Status Software fault or the system is initializing after electrifying ON The system is electrified PWR Green OFF The system is not electrified 8 10 100Mbps Ethernet electrical interfaces numbered 1 8 The 8 groups of indicators for the 8 10 100Mbps Ethernet electrical interfaces There are 3 indicators for an interface LNK ACT 100M and FDX...

Страница 11: ...port is working in full duplex mode FDX 10 100M Green OFF The corresponding port is working in half duplex mode or it is in Power OFF status The CONSOLE interface 3 2 Device rear panel description ISCOM2008 only provides a socket for 220V AC power supply on its rear panel see the figure below 1 2 In the figure shown above The place where the socket for 220V AC power supply locates The place where ...

Страница 12: ...afety of the device and the operator please make sure that the grounding terminal is well connected to the earth 4 3 The connection of the switch 4 3 1 Connect to console ISCOM2008 switch provides a RS 232 interface in the form of RJ 45 as the CONSOLE interface After connecting the CONSOLE interface of ISCOM2008 switch to the serial port on the PC using the provided cable users can configure and m...

Страница 13: ...tor is shown in the figure and table below Pin Number Function Type Pin Number Function Type 1 CD 6 DSR 2 RxD IN 7 RTS 3 TxD OUT 8 CTS 4 DTR 9 RI 5 GND Ground 3 CONSOLE interface connecting pattern and parameter setup The connecting of ISCOM2008 CONSOLE interface and PC serial port is shown in the figure below RxD TxD GND RxD TxD GND PC Serial Pot ISCOM2008 CONSOLE 3 2 5 6 3 4 5 The values of the ...

Страница 14: ...onnector and jack please refer to the CONSOLE interface signal definitions of the switch in section 4 3 1 Pin Number MDIX Signal MDI Signal 1 RD TD 2 RD TD 3 TD RD 6 TD RD 4 5 7 8 N C N C The 8 10 100M Ethernet electrical interfaces of ISCOM2008 switch works at MDIX mode when the auto negotiation function is disabled In this circumstance the interface can be connected to an opposite MDI interface ...

Страница 15: ...tch is electrified After the electrifying the indicator PWR will turn ON to indicate that the power supply of the system is working The switch will begin its self check and initialization in succession All the indicators on the front panel of the switch will turn ON during this procedure The switch will be in operating status after the self check and initialization The indicator SYS will begin to ...

Страница 16: ...w humidify may lead to fire alarm In a word the switch must be placed in proper surroundings The power supply of the device should be well earthed to let out the static electricity Please keep some space from other powered devices when installing the switch The cable arrangement of the switch should have all cables be placed across the live wire Long distance close parallel of the cables and the l...

Страница 17: ...ress 2nd Floor South Building of Rainbow Plaza No 11 Shangdi Information Road Haidian District Beijing Postcode 100085 Tel 86 10 82883305 Fax 86 10 82883056 Email export raisecom com http www raisecom com ...

Отзывы: