Combustion air supply 

In order for the stove to perform efficiently and safely there should be an adequate air 
supply into the room in which the stove is installed to provide combustion air.  This is 
particularly necessary if the room is double-glazed or a flue draught stabiliser is           
operating in the same room as the appliance. It may be necessary to increase the air 
vent size in property with low air permeability ( < 5.0 m

3

 /(h.m

2

). 

The provision of air supply to the stove must be in accordance with current Building 
Regulations Approved Document J. An opening window is not appropriate for this      
purpose. 
IMPORTANT NOTE: If applicable and the appliance is being fitted within an existing  
fireplace recess, specialist advice should be sought before fitting any permanent       
ventilation within this area. 
 

Connection to chimney 

Stoves may have a choice of either a rear or top flue gas connector that allows          
connection to either a masonry chimney or a prefabricated factory made insulated metal 
chimney in accordance with their instructions. In some cases it may be necessary to fit 
an adaptor to increase the diameter of the flue to the minimum required 150 mm section 
of the chimney or liner. 
 

Electrical Services 

The installation of any electrical services during the installation of this appliance must be 
carried out by a registered competent electrician and in accordance with the                
requirements of the latest issue of BS 7671 
 

Carbon Monoxide Alarm 

A carbon monoxide alarm complying with BS EN 50292 must be fitted in the same room 
as the appliance. It should be positioned on the ceiling at least 300mm from any wall or, 
if it is located on a wall, as high up as possible (above any doors and windows) but not 
within 150mm of the ceiling. The alarm should also be between 1m and 3m horizontally 
from the appliance. 
 
 

Содержание RINA

Страница 1: ...RAIS VIVA RAIS JUNO IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for t...

Страница 2: ...ON 19 INSTALLATION DISTANC 20 26 FOR THE INSTALLER 27 OPERATING INSTRUCTIONS 28 FUEL 28 DRYING AND STORAGE 30 REGULATION OF COMBUSTION AIR 30 ROOM VENTILATION AND STOVES 30 LIGHTING AND FUELLING 31 US...

Страница 3: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 3...

Страница 4: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 4...

Страница 5: ...er We therefore recommend that you note down the number in the table below The production number is located at the back of the stove at the bottom Warranty Your Rais wood burning stove comes with a 5...

Страница 6: ...11 Smoke gas mass flow g s 4 Smoke gas temperature C 271 Intermittent operation Fuelling should be undertaken within 3 hours Viva 98 Viva 98 G 4 6 Ca 30 90 440 980 295 225 393 320 225 393 1 2 12 98 79...

Страница 7: ...of the Health and Safety at Work Act are met Handling Adequate facilities must be available for loading unloading and site handling Fire Cement Some types of fire cement are caustic and should not be...

Страница 8: ...ficient draught Please Note this appliance has been tested by the manufacturers and works on a 3m straight flue The outlet from the chimney should be above the roof of the building in accordance with...

Страница 9: ...t J see also combustion air supply Adequate provision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe where it is not intended for the chimne...

Страница 10: ...ion within this area Connection to chimney Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a masonry chimney or a prefabricated factory made insula...

Страница 11: ...of your stove The stove should be set up at a safe distance from inflammable materials See the manufacturer s plate on the wood burning stove Commissioning and handover Ensure loose parts are fitted...

Страница 12: ...the installer that the installation work and com missioning checks described in the installation instructions have been carried out correctly and that the chimney has been swept clean is sound and fre...

Страница 13: ...kindling to prevent excessive smoke Fuel overloading The maximum amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Operation with door left open Operati...

Страница 14: ...be shut off or sealed USER OPERATING INSTRUCTIONS WOOD Please read the important notices given above before referring to the main instruction book for detailed operating instructions HETAS Ltd Approva...

Страница 15: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 15...

Страница 16: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 16...

Страница 17: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 17...

Страница 18: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 18...

Страница 19: ...a Rais Viva Rais Juno 19 Normal set up corner setting RINA A Distance to furniture 700 mm Distance to flammable materials B in front floor 300 mm C to the side floor 150 mm D to the rear floor 150 mm...

Страница 20: ...20 Normal set up corner setting VIVA VIVA G A Distance to furniture 700 mm 650 mm Distance to flammable materials B in front floor 300 mm 300 mm C to the side floor 150 mm 150 mm D to the rear floor...

Страница 21: ...Rais Viva Rais Juno 21 Corner setting 45 fixed socket RINA A Distance to furniture 700 mm Distance to flammable materials B in front floor 300 mm C to the side floor 150 mm D to the rear wall 150 mm...

Страница 22: ...22 Corner setting 45 fixed socket VIVA VIVA G Distance to furniture 700 mm 650 mm Distance to flammable materials B in front floor 300 mm 300 mm C to the side floor 150 mm 150 mm D to the rear wall 1...

Страница 23: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 23 360 Swivel Base VIVA VIVA G Distance to furniture 700 mm 650 mm Distance to flammable materials C to the side floor 300 mm 300 mm...

Страница 24: ...first time a check should be made to ensure that the assembly and stove installation has been satisfactory and that there are no leaks in any seals in the appliance and appliance connections to the ch...

Страница 25: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 25...

Страница 26: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 26...

Страница 27: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 27...

Страница 28: ...iods If this is the case then more frequent cleaning will be necessary Cleaning and maintenance The instructions detailed in the section Maintenance in the instruction booklet should be followed Spare...

Страница 29: ...gth of the combustion chamber minus 50 60 mm Stoking with wet firewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 70 water and is thoroughly unsu...

Страница 30: ...tion chamber and is pre heated through the side channels and then emitted as hot scavenging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be see...

Страница 31: ...n Light the fire and close the door 3 4 When the flames are clear after approx 10 15 min close the door completely 5 Damper see adjustment of air damper When the last flames are extinguished and there...

Страница 32: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 32...

Страница 33: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 33...

Страница 34: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 34...

Страница 35: ...ade of vermiculite Handle these parts carefully Remove dirt and dust and mount the parts in reverse order Remove the smoke converter plate by tilting it to one side and turning it a little slantwise P...

Страница 36: ...chimney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty sm...

Страница 37: ...ccessories and spare parts If spare parts other than those recommended by RAIS are used the warranty is voided All replacement spare parts can be purchased from your RAIS distributor stockist See the...

Страница 38: ...1 1 1312090 Glass door 2 1 3310404 Cover for wood compartment 3 1 3310601 Top plate without hole 4 1 3310602 Top plate with hole 5 1 61 00 Flue collar 6 6 1 1313800 Shaking grate 7 1 1314001 Ash pan 8...

Страница 39: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 39 RINA...

Страница 40: ...Part no Description 1 1 1312090 Glass door 2 1 2310601 Top plate without hole 3 1 2310602 Top plate with hole 4 1 61 00 Flue collar 6 5 1 1313800 Shaking grate 6 1 1314001 Ash pan 7 1 1311790 Air box...

Страница 41: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 41 VIVA 98...

Страница 42: ...y Part no Description 1 1 1312090 Glass door 2 1 2310601 Top plate without hole 3 1 2310602 Top plate with hole 4 1 61 00 Flue collar 6 5 1 1313800 Shaking grate 6 1 1314001 Ash pan 7 1 1311790 Air bo...

Страница 43: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 43 VIVA 120...

Страница 44: ...5 1 2310601 Top plate without hole 6 1 2310602 Top plate with hole 7 1 61 00 Flue collar 6 8 1 1313800 Shaking grate 9 1 1314001 Ash pan 10 1 1311790 Air box 11 1 1312200 Fire brick set 12 1 1315500...

Страница 45: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 45 VIVA 98 G...

Страница 46: ...5 1 2310601 Top plate without hole 6 1 2310602 Top plate with hole 7 1 61 00 Flue collar 6 8 1 1313800 Shaking grate 9 1 1314001 Ash pan 10 1 1311790 Air box 11 1 1312200 Fire brick set 12 1 1315500...

Страница 47: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 47...

Страница 48: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 48...

Страница 49: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 49...

Страница 50: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 50...

Страница 51: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 51...

Страница 52: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 52...

Страница 53: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 53...

Страница 54: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 54...

Страница 55: ...ENGLISH RAIS manual for Rais Rina Rais Viva Rais Juno 55...

Страница 56: ...anual for Rais Rina Rais Viva Rais Juno 56 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co u...

Отзывы: