IMPORTANT. 

Using a spirit level ensure that the stove is 
perfectly level both horizontally and 
vertically. 

Fixing hole for solid wall installation 

Fixing holes for the angle brace for a stud 
wall installation

Содержание RAIS Q-BIC

Страница 1: ...NT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the door seal and sealant to...

Страница 2: ......

Страница 3: ...ER INSTALLATION 45 22 360 SWIVEL BASE 22 FOR THE INSTALLER 23 OPERATING INSTRUCTIONS 24 FUEL 24 DRYING AND STORAGE 25 REGULATION OF COMBUSTION AIR 25 USING THE WOOD BURNING STOVE 26 ADJUSTMENT OF AIR...

Страница 4: ...n number We therefore recommend that you note down the number in the table below The production number is located at the back of the stove at the bottom Warranty Your Rais wood burning stove comes wit...

Страница 5: ...gs of wood approx 25cm 1 6 1 6 Min uptake Min draught Pascal 12 12 Weight kg 143 153 Smoke gas mass flow g s 6 3 6 3 Smoke gas temperature C 253 253 Intermittent operation Fuelling should be undertake...

Страница 6: ...e cold air is sucked in at the base of the stove and up through the convection channel which runs along the stove s combustion chamber The heated air comes out at the top of the stove which ensures a...

Страница 7: ...s heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met during the installation works At...

Страница 8: ...accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and should have been swept clean immediately before the installation of the stove If the sto...

Страница 9: ...ssible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2 flues For strong draugh...

Страница 10: ...egulations Approved Document J gives specific guidance on the required permanent ventilation into the room for combustion air of solid fuel appliances The floor structure must be able to carry the wei...

Страница 11: ......

Страница 12: ...rner both door side DO NOT UNSCREW ENTIRELY Now it is possible to remove the stove body from the cassette Preparation of the cassette Remove the two screws keeping the stiffening rib in position For a...

Страница 13: ...oken off before it is assembled with the two self tapping screws The top plate is not used N B A 30 degree bend must always be used for a brick wall The legs are fixed onto the box and then the box ca...

Страница 14: ...ORTANT Using a spirit level ensure that the stove is perfectly level both horizontally and vertically Fixing hole for solid wall installation Fixing holes for the angle brace for a stud wall installat...

Страница 15: ...picture on the left Note The basic settings on the adjusting bolts are approximately 32 5mm between the bottom of the stove s base plate and the base plate on the internal box Please note adjustment...

Страница 16: ...Push the stove body in until the front is level with the wall on both sides Re tighten the screws in the upper left and lower left corners...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...a non combustible hearth of a size and construction that is in accordance with the provisions of the current UK Building Regulations Approved Document J If the stove is to be installed on a wooden fl...

Страница 21: ...Q Bic...

Страница 22: ......

Страница 23: ...to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user Read the later parts of this manual for guidance on care required when first...

Страница 24: ...wood wood with a synthetic surface painted refuse wood chipboard plywood domestic waste paper bri quettes and pit coal as this will produce malodorous smoke which could be poisonous When firing with...

Страница 25: ...is added in the gas combustion zone i e air which contributes to the combustion of the pyrolysis gasses preheated air which is used for the cleaner glass system and combustion This air is sucked thro...

Страница 26: ...ration Using the wood burning stove Adjustment of the air damper the damper has 3 settings Rais Q Bic Position 1 The damper closed which means no air supply Position 2 Push the handle to the left to t...

Страница 27: ...which means no air supply Position 2 Push the handle to the left to the first mark This position gives full secondary air During normal use the lever is set between position 1 and 2 When the flames a...

Страница 28: ...ot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPORTANT Warning Note Proper...

Страница 29: ...ighting the stove Tips before firing up Open a door or window close to the wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a screwed up piece of news...

Страница 30: ...bers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes or when the flames are clear an...

Страница 31: ...ovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste or recycle on the garden REMEMBER Never remove all the ashes...

Страница 32: ...arked by a circle in the next picture The baffle plate is pulled forwards and then tipped down towards the firebox Note the skamol on the sides are now loose The smoke connector is located above the b...

Страница 33: ...2 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty smoke channels leaking chimney...

Страница 34: ...agrams for the individual products Position Number Item Number Description 1 1 706060290 95 Top plate 2 1 706010490 95 Steel back panel 3 1 706010590 95 Fixed window 4 1 706010190 95 Steel side panel...

Страница 35: ......

Страница 36: ...panel 3 1 706010590 95 Fixed window 4 1 706010190 95 Steel side panel 5 1 7061090 95 Door 6 1 7060905SV Air control handle 7 1 7061301 Smoke connector 8 1 7062200 Set of skamol stones 9 1 7060590 95 F...

Страница 37: ......

Страница 38: ...d window 3 1 7061090 95 Door 4 1 7060905SV Air control handle 5 1 7061301 Smoke connector 6 1 7062200 Set of skamol stones 7 1 7071301SV Complete smoke connector 45 adaptor 8 1 0006504 Complete smoke...

Страница 39: ......

Страница 40: ...U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk June 2011...