background image

17

English  

 

 

 

 

RAIS - Manual for RAIS Q-Tee

Installation distance in case of non-combustible wall

We recommend a minimum distance to non-combustible material of 50 mm (F) for 

cleaning considerations.

It should always be possible to access the access door.

Содержание Q-TEE

Страница 1: ...N G S A N L E I T U N G U S E R M A N U A L M A N U E L D U T I L I S AT E U R B R U K E RV E I L E D N I N G B R U K S A N V I S N I N G K Y T T O H J E G E B R U I K E R S H A N D L E I D I N G RAIS...

Страница 2: ...LEDNING DE 275 mm SIEHE BEDIENUNGSANLEITUNG UK 275 mm SEE USER MANUAL FR 275 mm CONSULTEZ LE GUIDE DE L UTILISATEUR DK 650 mm SE BRUGERVEJLEDNING DE 650 mm SIEHE BEDIENUNGSANLEITUNG UK 650 mm SEE USER...

Страница 3: ...od burning stove Bruk av peisovn Anv nda kaminen Tulisijan k ytt minen Utilisation du po le Gebruik van de kachel Position 1 Posisjon 1 Asento 1 Stand 1 Position 2 Posisjon 2 Asento 2 Stand 2 Position...

Страница 4: ...Use dry brushwood kindling and possible a piece of news paper Open the air damper so plenty of air is fed to the stove and the gases from the heated wood can burn rapidly 2 Light the fire with only li...

Страница 5: ...LL 17 MOUNTING OF WALL BRACKET AND INSTALLATION OF Q TEE WALL 18 19 Q TEE INSERT 20 25 OVERALL DIMENSIONS 20 ASSEMBLY INSTRUCTIONS 21 BUILT IN DIMENSIONS WALL OPENING AIR SYSTEM 22 PLACEMENT OF Q TEE...

Страница 6: ...l thoroughly before installing and using it In the case of warranty coverage and for general queries regarding your wood burning stove it is important that you know the stove s production number We th...

Страница 7: ...2 3 logs of wood of approx 25 cm 1 5 1 5 1 5 1 5 Min uptake Min draught Pascal 12 12 12 12 Weight steeldoor glassdoor kg 79 81 82 84 94 96 94 96 Efficiency 80 80 80 80 Particles acc to NS3058 3059 g...

Страница 8: ...governed by the Health and Safety at Work Act 1974 It is the responsibility of the installer to ensure that all requirements of this Act are met during the installation works Attention is drawn in pa...

Страница 9: ...rom the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound...

Страница 10: ...ught stabiliser should be fitted The adjustable flue damper should not close off the flue entirely but should in its closed position leave a minimum continuous opening free area of at least 20 of the...

Страница 11: ...blocked The floor structure must be able to carry the weight of the wood burning stove as well as the weight of a chimney if necessary The stove is placed on fireproof material for the freestanding mo...

Страница 12: ...emove the blanking plate and the packing and position them in the hovle at the top Ensure that the packing is positioned correctly Screw all elements together with the three M6 nuts Mount the flue col...

Страница 13: ...ordance with the provisions of the current UK Building Regula tions Approved Document J If the stove is to be installed on a wooden floor it must be covered with a non combus tible material at least 1...

Страница 14: ...rmal set up corner setting Uninsulated flue Insulated flue A Distance to furniture min 650 mm 650 mm Distance to flammable materials min B in front floor 300 mm 300 mm C to the side floor 150 mm 150 m...

Страница 15: ...mum distance to non combustible material of 50 mm F for cleaning considerations It should always be possible to access the access door Corner setting 45 fixed socket Uninsulated flue Insulated flue A...

Страница 16: ...st be covered with a non com bustible material at a thickness and seize which is in accordance with UK Building Regula tions Normal set up corner setting Uninsulated flue Insulated flue A Distance to...

Страница 17: ...for RAIS Q Tee Installation distance in case of non combustible wall We recommend a minimum distance to non combustible material of 50 mm F for cleaning considerations It should always be possible to...

Страница 18: ...and other fastening material are not included in the delivery from RAIS The holes are marked up through the holes in the bracket All holes are drilled a mini mum of 2 holes must be in a brick The flue...

Страница 19: ...to be tightened because of the downward expansion of the stoves during heating Finally 2 M4 screws 7 are screwed on each side of the bracket and locks the stove to the bracket See the top of the page...

Страница 20: ...20 A A English RAIS Manual for RAIS Q Tee Q Tee INSERT Overall dimensions...

Страница 21: ...erwise it is recommended in other installations Place the mantle 8 in the wall opening adjustment is done using the 4 set screws Be aware that the mantle must be leveled and adjusted vertically and ca...

Страница 22: ...l Built in dimensions wall opening The wall opening is min 613mm x 473mm height x width The depth is min 475 mm non combustible panel and min 425mm brick A fireplace insert must never be built in tigh...

Страница 23: ...Placement of Q Tee INSERT Ventilation use the insert optimally Consider the placement of convection and outlet holes Ensure that the area require ments are respected and that the holes are not blocke...

Страница 24: ...n 300 mm Distance to non combustible plate min 800 mm Installation height min 400 mm Min 300 mm Min 150 mm Min 150 mm Min 100 mm Distance to combustible material min 200 mm f ex door frame Distance to...

Страница 25: ...n 650 mm Distance to non combustible 0 mm 10 mm is recommended Installation height min 400 mm Min convection area 350 cm2 be low the stove may be distributed To guide the hot air out of the convection...

Страница 26: ...king split dried firewood The firewood must have a water content of 15 22 and its max length should be the length of the combustion chamber minus 50 60 mm Stoking with wet firewood causes both soot en...

Страница 27: ...oid covering the firewood stacks with plastic as this prevents the moisture from escaping It is a good idea to bring the firewood into the house 2 3 days before you need it Regulating the combustion a...

Страница 28: ...safely and efficiently In accordance with current Building Regulations the installer may have fitted a perma nent air supply vent into the room in which the stove is installed to provide combustion ai...

Страница 29: ...gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPORTANT Warning...

Страница 30: ...spj ldet helt samt eventuel l ge p klem eller t nd op forfra Advarsel Hvis br ndet kun ulmer eller ryger og der tilf res for lidt luft udvikles der uforbr ndte r ggasser R ggas kan ant ndes og eksplod...

Страница 31: ...s been coated with a high temperature paint which can last for years Do not clean with a damp cloth or any cleaning products as they can cause rust or discolouration Only clean when cold use a brush w...

Страница 32: ...ulit Handle these parts carefully Remove the smoke converter plate by tilting it to one side and turning it a little slant wise Pull out the plate carefully Then remove the smoke chicane by pushing it...

Страница 33: ...le air supply for room ventilation unclean smoke channels leaky chimney leakage between chimney and flue If your stove continues to malfunction we recommend that you contact your RAIS distributor or c...

Страница 34: ...ee 65 2 1 835010290 Mantle Q Tee 57 3 1 8352090 Steel door 4 1 8351090 Glass door 5 1 835050490 Cover Q Tee 65 6 1 835052490 Cover Q Tee 57 7 1 8352200 Fire brick set 8 1 8353800 Shaking grate 9 1 835...

Страница 35: ...35 1 10 13 6 5 8 3 4 2 11 12 9 14 7 15 18 17 16 English RAIS Manual for RAIS Q Tee Spare parts...

Страница 36: ...36...

Страница 37: ...37...

Страница 38: ...4 6 1 2 3 5...

Страница 39: ...ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham Switzerland www attika ch RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk...

Отзывы: