Control
If the ash is white and the walls in the combustion chamber are soot free after the stove
has been used, the air regulation was set correctly and the wood was sufficiently dry.
Using the wood burning stove
Adjusting the air damper. The damper has 3 settings.
Position 1
The damper is closed meaning that there is no air
supply.
Position 2
Push the handle to the left, to the first mark.
This position gives full secondary air.
During normal use the lever is set between position 1
and 2.
When the flames are clear and yellow, the damper is set
correctly, i.e. resulting in a slow/optimal burning.
Position 3
Push the handle to the left to the stop.
The air damper is completely open and gives full primary
and secondary air. This position is for the lighting stage
and is not used under normal operation.