RAIS attika VISIO UNIQ Скачать руководство пользователя страница 11

EN

EN - 10

Important!

For delivery, the door is locked in transit and it must be released 

before installation. This is done by removing the two transport 

screws in the counterweights on the back of the stove!

TRANSPORT SAFETY FITTINGS

Содержание attika VISIO UNIQ

Страница 1: ...O UNIQ DK INSTALLATIONSVEJLEDNING DE INSTALLATIONSANLEITUNG EN INSTALLATION GUIDE FR NOTICE D INSTALLATION NO INSTALLASJONSVEILEDNING SE INSTALLATIONSANVISNING FIN ASENNUSOHJEET NL INSTALLATIEHANDLEID...

Страница 2: ...EN 1 EN SERIAL NUMBER MUST BE PLACED HERE...

Страница 3: ...tions 8 Norway specific instructions 9 Transport safety fittings 10 Reflective insulation panel 11 Choice of material for installation 13 Installation dimensions 15 Placement distances 16 Heat distrib...

Страница 4: ...he floor from falling embers The fireplace insert must be positioned at a safe distance from flammable material Due to risk of fire flammable items e g furniture may not be positioned closer to the in...

Страница 5: ...H mm 482 X 279 X 250 Min flue draught pascal 12 Weight kg min depending on the model 268 Efficiency 78 CO emission attributed to 13 O2 0 0714 893 mg Nm NOx emission attributed to 13 O2 mg Nm 113 OGC e...

Страница 6: ...12 n198 n198 1465 632 0 139 414 926 1398 1525 292 445 445 n149 159 4 364 5 428 691 500 512 891 891 445 632 143 512 n198 n198 1465 632 0 139 414 926 1398 1525 R149 292 445 445 n149 159 445 445 364 5 42...

Страница 7: ...the installation and operating instruction manual Intermittent operation F Veuillez lire et observer les instructions du mode d emploi Foyer dur e de combustion limit e homologu pour chemin e connexi...

Страница 8: ...be removed DISPOSAL RECYCLING OF PACKAGING The fireplace insert is delivered in recyclable pack aging This packaging must be disposed of in ac cordance with national regulations relating to the dispos...

Страница 9: ...r in the flue Before Visio Uniq may be installed in a smoke controlled area of the UK a stopper must be installed This will prevent the flue from closing entirely This is done by setting the flue hand...

Страница 10: ...f a mechanical stopper in the flue Before Visio Uniq may be installed in Norway a stopper must be installed This will pre vent the flue from closing entirely This is done by setting the flue handle in...

Страница 11: ...tant For delivery the door is locked in transit and it must be released before installation This is done by removing the two transport screws in the counterweights on the back of the stove TRANSPORT S...

Страница 12: ...flective insulation panel must be installed to cover the flue collar up to the insulated chimney pipe The reflective insulation panel is included and is found screwed onto the back of fire place inser...

Страница 13: ...d the two cut out easy bend flanges 90 see photo below Loosen the two labelled screws one on each side Place the two bottom holes on the reflective insulation panel over the two screws on the back of...

Страница 14: ...inspector During testing the fireplace insert is installed in a cabinet made of non flammable 50 mm calcium silicate panels Skamotec 225 The stove comes with a flue collar that is 200 mm in diameter...

Страница 15: ...EN EN 14...

Страница 16: ...must never be tightly inserted into a cavity as steel expands when heated There must be a minimum convection air intake of 400 cm underneath the stove and 600 cm above it The minimum convection air ar...

Страница 17: ...EN 16 SET UP The insulated chimney must extend all the way down to the flue outlet adapter To guide the hot air out of the convec tion grates a non flammable plate must be installed just over the grat...

Страница 18: ...rniture 650 Interior distance to cabinet 50 Distance from vertical frame to flammable wall 100 If the insulation value is complied with greater than 0 03 m x K W the cabinet may be installed against a...

Страница 19: ...ce insert is installed so that the vertical built in frame is flush against the wall the first 100 mm of the wall must be made of non combustible material such as 50 mm Skamotec 225 or brick INSTALLAT...

Страница 20: ...EN 19 EN HEAT DISTRIBUTOR HEAT DISTRIBUTOR By installing a heat distributor unit above the fireplace insert heat can be transported to other rooms...

Страница 21: ...flexi hose metal EXTERNAL AIR CONNECTION AIRSYSTEM All RAIS ATTIKA fireplace inserts can have an external air connection for combustion We call this external air supply AirSystem The system can be co...

Страница 22: ...ins to crumble The liner panels are easy to place in position in the fireplace insert and can easily be replaced by you or your dealer Procedure for removing the combustion chamber lining 1 Remove the...

Страница 23: ...ion chamber lining A steel baffle is positioned between the two convection ducts above the flue panel The steel baffle is held in place by two guide pins Remove the steel baffle by pushing the front e...

Страница 24: ...n the upper locking pawl which is located above the door is released by turning it to the right on the right side and left on the left side The door is lifted so that the lower locking pawl is just fr...

Страница 25: ...nderneath the grate can be removed and emptied in a non combustible container until it has cooled off Ash can be disposed of as ordinary household waste REMEMBER Never remove all the ash from the comb...

Страница 26: ...or the counterweight cover Transport safety fitting 2 Remove the counterweight cover by pulling it up Counterweight cover 3 Loosen the locking ring 2 5 mm hex key Remove the number of counterweights t...

Страница 27: ...s 1 Remove the side Skamol panel 2 Remove the access panel 3 Loosen the locking ring 2 5 mm hex key Remove the number of counterweights that allow the door to close slowly and at a constant speed Doub...

Страница 28: ...EN 27 EN DECLARATION OF PERFORMANCE DECLARATION OF PERFORMANCE...

Страница 29: ...ter NS 3058 2 12 g kg t rstof middelv rdi krav 4 Partikler efter NS 3058 2 12 g kg t rstof maksimalt krav 8 OGC efter CEN TS 15883 57 mgC Nm ved 13 O2 krav 120 St v efter FprEN 16510 1 23 mg Nm ved 13...

Страница 30: ...EN 29 EN...

Страница 31: ...EN EN 30...

Страница 32: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham Switzerland www attika ch...

Отзывы: