Always keep the rooftop area clean and do not keep any hazardous materials like
paints, glass items, chemicals, rusted old junk materials etc, on rooftop.

Sheltering and leashing of domestic pets on rooftops is to be strictly avoided in
order to maintain the cleanliness and to avoid the contamination of rainwater.

Do not wash clothes on the rooftop, this leads to the flow of detergent water
through filter reaching the sump or recharging well. It is very harmful to the
human health. Precautions should be taken to avoid the detergent water reaching
the sump or the recharging well.

Rainwater is the purest form of water. If you want to use it for potable use, it is

advised to

the water by competent authorities before potable usage.

Do not keep your tank's door open. Exposure of rainwater to atmosphere leads to
speedy algae formation. Avoid exposing the water stored in the sumps to direct
sunlight and air.

• ‘

Rainy

Filters works on Gravity. Therefore, make sure that the level of delivery

pipe line always runs down below the clean water outlet line. Also, make sure that
the gravity head is more than one (1) foot ( 0.06 Kg/cm )

• ‘

Rainy

filters are open ended. Therefore, do not close the drain outlet at any given

point.

Select the appropriate filter model based on your rooftop area. If the roof area
exceeds the filter-specific area, there might be variations in filter performance.
This might lead to overloading and can cause damages to the pipeline, ejecting
the overflow from the filter or up towards rooftop.

If the rooftop is very high ( 30 meters and above) the water pressure should be
brought down by incorporating air releaser in series with the pipeline or through
any other method that can bring the pressure down. This is done to avoid water
hammer.

• ‘

Rainy

Filters are exclusively designed for rainwater harvesting. Do not use these

filters for other purposes.

• ‘

Rainy

filters are designed to remove only suspended particles up to 250

Microns. These filters do not filter biological or chemical contaminations.

Do not use any chemicals while cleaning the filter/filter element.

Strictly restrict the entry of hazardous chemical substances to the filter.

Filter must be installed away from any heating units/electrical components/gas

cylinders/furnaces etc, in order to avoid damage/destruction of the filter.

analyze

2

Содержание FL-150

Страница 1: ...FL 150...

Страница 2: ...al properties belonging to Farmland Rainwater Harvesting Systems which is a criminal offence apart from liabilitytopaydamages 1 Read and understand all instructions in the USER GUIDE for the best prod...

Страница 3: ...Recharging 6 04 GeneralTechnical Information 7 05 About us 8 06 Introduction 8 07 Rainy FLSeries Technical Parameters 12 08 Overall view of the Dual Intensity RWH Filter 13 09 Filter Installation Inst...

Страница 4: ...o natural distillation process i e evaporation condensation and precipitation It is supposed to be in very dilute solution with verylessdissolvedsolidsgenerallybetween10 20mg Liter All the dissolved i...

Страница 5: ...Option 3 Recharging of the borewell if roof area is more than 200 Sq mts through Farmland V Wire Technology Option 4 Recharging of Open Well Please note that the intake of rainwater depends upon the c...

Страница 6: ...V wire injection well technology can be used to recharge groundwater sources and replenish the water table Run off rainwater is made to pass into a silt trap through a channel and then to an injectio...

Страница 7: ...he roof area available for harvesting the rainwater while considering either highest rainfall per day or 5 of average annual rainfall For the above said area the ideal tank capacity would be 5000 lite...

Страница 8: ...HydraulicTestingLabequippedwiththelatestmachinery Our widespread dealer network spanning over 11 countries with highly trainedfieldserviceengineersarealwaysavailabletosolveeveryquery Congratulations o...

Страница 9: ...w National and International Awards National award in the year 2009 from Confederation of Indian Industry CII as Most Innovative Water Saving Product and International award in the year 2010 from JSW...

Страница 10: ...simultaneously divert clean water into the sump recharging well through the clean water outlet which can be used for reutilization or recharging of groundwater source Special Features Since the filter...

Страница 11: ...the sump and reutilizing around 35 of the annual water requirement of a household can be met Thereby a considerable amount on water and power bill can be saved Dependency on water tankers groundwater...

Страница 12: ...sive Force Centrifugal Force Operating Pressure 1 foot of Gravity Head 0 060kg cm Max Discharge at CWO 180 LPM Filter Element SS 304 Multi Surface Screen Food Grade Mesh Size 250 Microns Inlet size 90...

Страница 13: ...Clean water outlet adapter 06 Straps 07 Wall Bracket 08 Lower housing 09 CWO bush 10 CWO adapter 11 Bellow for drain outlet 01 Filter cap 02 Upper Housing 03 Union 04 Filter element SS 304 05 Interme...

Страница 14: ...Interconnect the down flow pipes and draw the line till the point of filter location Filter Installation Instructions Keep the roof clean...

Страница 15: ...he filter assembly on the wall bracket Then pull the strap and hook up to the wall bracket Place the filter against the wall to spirit level as shown in the figure and mark the point to fix the wall b...

Страница 16: ...Drill the holes to the wall as per the marking Fix the wall bracket with anchor bolts and tighten the nuts correctly...

Страница 17: ...Fix the filter to the wall bracket through straps Set the direction of filter inlet and outlet just by rotating to suit the pipe connection by hand...

Страница 18: ...ngular clamps with U bolts and anchor bolts with adjustable C Clamps at inlet pipe Once the direction of filter inlet and outlet pipe connections are set connect the downspout pipe to the inlet of the...

Страница 19: ...Insert the bellow to the drain outlet with clips Insert the pipe with elbow into the bellow Fix the L angular clamps with U bolts and clips to sustain the weight of the drain pipe...

Страница 20: ...Connect the delivery line to the sump recharging well with necessary length of pipe and fixtures Insert adapter into the bush Insert bush into the clean water outlet...

Страница 21: ...Insert the filter element inside the upper housing Remove the fiber cap by rotating in clockwise direction...

Страница 22: ...Lock the filter cap by rotating anticlockwise Open Drain Filtered water line Completion of the filter installation...

Страница 23: ...2 In asbestos sheet rooftop 3 In dust prone areas 4 Where lots of moss is grown on rooftop Unlock the filter element cap with two hand rotation and remove the filter outside for cleaning purpose Dire...

Страница 24: ...Wash it clean it well and re insert the same Clean it up with a brush...

Страница 25: ...eleasing more discharge at drain outlet Once cleaning is done lift the filter element and observe under the sunlight light should pass through the filter element sieve If sunlight passes re insert the...

Страница 26: ...clear light passes through thefiltersieve 4 There might be chances of blockage at entry point of roof top rain inlet pipe blockage in the elbows or joints of rainwater pipe line connections blockage...

Страница 27: ...line Also make sure that thegravityheadismorethanone 1 foot 0 06Kg cm Rainy filters are open ended Therefore do not close the drain outlet at any given point Select the appropriate filter model based...

Страница 28: ...Rainy FL 150 S N...

Страница 29: ...fails to perform the functions as indicated in the user manual brochure technical guide or any other similar documents supplied with the filter Fading color of the filter ageing of materials or change...

Страница 30: ...tension a Immediately and effectively notify Warrantor about determined filter s defects within timetobespecified andceaseanyfurtherusage b A copy of commercial invoice should be provided to the warra...

Страница 31: ...terations made without prior written approval for products clogged by suspended matter precipitates or biologicalgrowth orforfailureresultingfromthelackofpropermaintenance 17 Under no circumstances th...

Страница 32: ...ustomer Care Address FL 150 Farmland Rainwater Harvesting Systems No 269 1 Hadihalli Village Amble Hobli Malalur Gram Panchayat Malalur Post Chikmagalur Taluk and District 577133 Karnataka State India...

Отзывы: