10
"Mr. Drain"
AIR GAP
STAND PIPE
FOR
WASHER,
DRAIN
STACK
!
Important Note: The air gap
should be two times the diam-
eter of the drain line or a
minimum of two inches. Please
check your local plumbing
codes to ensure compliance.
Wrap PTFE Thread
Sealant Tape Around
1/2" NPT Fitting
Figure 5
Figure 6
•Ensure that the bypass valve is in Bypass position. The valve
handles should be perpendicular to the pipes (see figure 4).
9. Install the Drain Line and Air Gap
(Air Gap Not Supplied)
• For all drain lines, use at least a 1/2 inch I.D. line.
•Connect the drain line to the drain outlet on back of the valve,
opposite the inlet connection (see figure 5). A fitting is required
to connect the female pipe thread to the drain line.
Figure 4
• Run the drain line to the air gap. The air gap must be installed between
the end of the drain line and the drain to prevent possible back siphoning
( see fig 6)