background image

— 2 —

1. Insert the batteries and tighten the timer on the faucet.
2. Keep the tap turned off and turn the dial on the timer to ON.
3. Press and hold the OK button for 3-5 seconds to manually open the valve in
the timer.
4. Press and hold the OK button for 3-5 seconds to manually open the valve
inside the timer, then press and hold for another 3-5 seconds to close the valve.
5. Repeat step 3, 3 to 5 times.
6. Turn on the tap, press and hold the OK button for 3-5 seconds and open the
valve manually again.
7. Open the valve manually again and check that everything is OK.
8. Then press and hold the button again for 3-5 seconds and turn it off manually.
9. If you still can't turn off the timer properly, repeat steps 3-4 several times (10
times)

Clean the inlet screen of impurities and restart the valve according to the above
steps.

Press and hold the OK button to open the valve manually to check that it
opens/closes properly.

Turn the knob to the off button to check if the valve can be closed.

Q: What if there is water mist in the screen of the timer?

The temperature difference between the inside and outside of the device is too
great, it will return to normal after a period of time and will not affect the

Содержание ITV205

Страница 1: ...ITV205 Two Zone water timer FAQ ...

Страница 2: ...Q Screen shows U 12 when powered up 3 Q Is the rainfall delay time not adjustable 3 Q I don t know how to enter exit the rainfall delay state 3 Q I don t know how to turn off the irrigation schedule 3 Q How do I set up separate access plans 3 Plan not executed on time 4 Q What should I do if I have set a schedule but it is not executed on time 4 Problems with water 4 Q What should I do if the wate...

Страница 3: ...imer vertically on the floor to avoid damage to the inside of the unit We do not recommend using it at an angle even horizontally as this may damage the internal valves and cause leaks Q What should I do if the valve cannot be opened closed The batteries are low and cannot drive the valve body Need to replace with brand new 2 AAA alkaline batteries You can restart the valve by following the steps ...

Страница 4: ...Open the valve manually again and check that everything is OK 8 Then press and hold the button again for 3 5 seconds and turn it off manually 9 If you still can t turn off the timer properly repeat steps 3 4 several times 10 times Clean the inlet screen of impurities and restart the valve according to the above steps Press and hold the OK button to open the valve manually to check that it opens cl...

Страница 5: ...nob to the ON page and press and hold the button for 3 seconds to enter or exit the rainfall delay state Q I don t know how to turn off the irrigation schedule If you don t want the schedule to continue turn the knob to the OFF page and the schedule will not run on time and the valve will not open If you just want to turn off the irrigation schedule and continue using the unit turn the knob to the...

Страница 6: ...low it will go into low battery protection and the schedule will not run Q What should I do if the water pressure is too low Install a booster pump or other method of increasing the pressure the product itself does not have a pressurisation function Q Little or no water coming out Clean the impurities from the timer filter Make sure the appliance valve is in the open position Open the hose tap Q W...

Страница 7: ...npoint Service Centre by phone or email It is important that you do not disassemble and repair the unit yourself as this could be dangerous Phone 1 833 3815659 Email service rainpointus com You can also visit our official website at www rainpointus com for more information on our products ...

Отзывы: