3.  To clean ceramic, (

Note:

 Please wear rubber gloves) hold cartridge in palm of hand with nozzle up and gently scrub entire    

 

surface with abrasive screen cleaner (811-0) provided under running water until light colour of ceramic returns. Do not allow    

 

water to enter nozzle opening.

DO NOT USE SOAP OR DETERGENTS.

 Scrubbing removes trapped particulates along with    

 

part of the ceramic.

4.  Insert ceramic cartridge with adaptor (2560) back into head boss. Replace sump and turn 1/8 turn to right fully to stop (lock    
 position). 

Note

: Bottom of sump has 4 guides to contain 1M cartridge. Sump will not lock unless bottom of cartridge is  

 

 between 

guides.

5.  Open water flow  then open faucet until all trapped air has escaped. If air remains in ceramic housing, turn off faucet and  

 

 

press top vent button until water level rises past sealing point on sump. 

Replacing CF2, LR1 Cartridge - Every 6 months or 375 US Gallon (1419 Liters)

1. Close saddle valve off and open faucet to relieve pressure in filter. Press vent buttons on top of both heads.
2. Remove right sump and lower and at same time remove carbon cartridge by twisting and gently pulling downwards. Transfer    
  cartridge and sump to sink and dump water. Do the same for the middle housing and the LR1 cartridge.
3. Insert new CF2 & LR1 cartridges onto head boss's and replace and lock sumps. Start water flow.
4. Turn on faucet until trapped air has escaped. If air remains in housing, turn off faucet and press top vent button until water  

 

  level rises past sealing point on sump. Note: Some fines from carbon cartridge may be flushed onto ceramic cartridge. These    
  are harmless and are removed with next cleaning.

Replacing 1M Ceramic Cartridge - Every 12 months or 1000 US gallon (3785 Liters)

1. Follow steps 1 & 2 above to remove sump and ceramic cartridge only.
2. 

REMOVE CARTRIDGE ADAPTOR (2560) FROM OLD CARTRIDGE

. Thread adaptor onto new cartridge. Take care not to  

 

  cross thread. Wipe any accumulated dirt from head boss before inserting new cartridge.
3. Replace cartridge by twisting and pushing adaptor up gently on head boss. Replace and lock sump. Open saddle valve to start  
water flow.
4. Turn on faucet until trapped air and carbon fines are flushed. If air remains in ceramic housing, turn off faucet and press top    
  vent button until water level rises past sealing point on sump.

MAINTENANCE / CAUTIONS
Caution:

 If your unit is not used in winter, or will be subject to freezing temperatures, drain unit and remove cartridges from 

sumps. Place cartridges in sink or on a paper towel to dry, which will occur in several days.

Note:

 Lubricate Head O-rings (2502) at least once a year and when draining for winter. Use food grade silicone grease (i.e. Dow 

111 compound) or any other non petroleum lubricant. Water conditions can be hard on rubber seals. Head O-rings (2502) should 
be replaced at least every two years. This is recommended to minimize wear and tear and prevent leakage.

Caution:

 Due to a limited product service life and to prevent costly repairs or possible water damage, we strongly recommend 

that sumps (#520) be replaced every 5 years. If sumps of your filter unit have been used for more than this period, replace 
immediately. Date the bottom of any new sump to indicate next replacement date.

Do Not

 clean housing with organic solvents such as those found in sprays for cleaning products or insecticides as these may 

cause cracking or crazing and lead to failure and leakage.

Protect

 filter from direct sunlight. Not intended for outdoor use.

Note:

 

For cold water use only.

TROUBLESHOOTING GUIDE
Problem

 

Possible Cause/Solution

1. Sump is difficult to remove 

- Unit may still be under pressure. Close saddle valve and

     

  open faucet to relieve pressure. Then try again.

 

 

-  Head O-ring may be stuck. To break the seal, push up on

     

  the sump before turning to unlock.

2. Leak at Head O-ring 

- O-ring may be dry or cracked due to age. Remove sump,

     

  cartridge and O-ring. Lubricate O-ring with food grade

     

  Silicone (i.e. Dow 111 Compound) or non petroleum

     

  lubricant and reinstall.  If seal still leaks, replace it.

3. Leak at Vent Button 

-  Vent O-ring is not seating properly or is dry or cracked.

     

  Press vent button several times to re-seat vent o-ring. 

     

  If O-ring still leaking, contact Envirogard for vent O-ring

     

  replacement kit.

4. Flow rate is very slow after installation of unit 

- Call Envirogard to review installation procedure.