background image

Replacing the Cartridge

Cartridge life is directly dependent on water conditions and the volume of water filtered. Replace the cartridge when taste and 
odour returns.  Replacement may be required more frequently if water has excessive taste/odour. 
1.  Close valve and open faucet to depressurize filter. Press vent button on top of head.
2.  Turn sump 1/8th turn to left and lower to remove. Remove old cartridge and replace. Replace sump and turn 1/8th turn to    
 

right fully to stop (lock position).

3.  Open valve and allow water to run until clear. Close faucet.

Maintenance / Precautions

    

Caution:

 If your unit is not used in winter, or will be subject to freezing temperatures, drain unit and remove cartridges from 

sumps. Place cartridges in sink or on a paper towel to dry, which will occur in several days.

Note:

 Lubricate Head O-ring (2502 at least once a year and when draining for winter. Use food grade silicone grease (i.e. Dow 

111 Compound) or another non petroleum lubricant. Water conditions can be hard on rubber seals. Head O-ring replacement at 
least every two years is recommended to minimize wear and tear and prevent leakage.

Caution:

 Due to a limited product service life and to prevent costly repairs or possible water damage, we strongly recommend 

that sumps (#520) be replaced every 5 years. If sumps of your filter unit have been used for more than this period, replace 
immediately. Date the bottom of any new sump to indicate next replacement date.

Do Not

 clean housing with organic solvents such as those found in sprays for cleaning products or insecticides as these may 

cause cracking or crazing and lead to failure and leakage.

Protect

 filter from direct sunlight. Not intended for outdoor use.

Troubleshooting Guide
Problem

 

Solution

1. Sump is difficult to remove 

-   Unit may still be under pressure. Close  valve and

 

    

 

open faucet to relieve pressure. Press and hold vent button

 

    

 

on top of head

 

 

-   Head O-ring may be stuck. To break the seal, push up on the

 

    

 

sump before turning to unlock.

2. Leak at Head O-ring 

-   O-ring may be dry or cracked due to age. Remove sump,

 

    

 

cartridge and O-ring. Lubricate O-ring with food grade

 

    

 

silicone (i.e. Dow 111 Compound) or non petroleum

 

    

 

lubricant and reinstall. If seal still leaks, replace it or call

 

    

 

Envirogard for advice.

3. Leak at Vent Button 

-   Vent O-ring is not seating properly or is dry or cracked. Press

 

    

 

vent button several times to re-seat. If still leaking, contact

 

    

 

Envirogard for vent O-ring replacement kit.

 

 

Operating Specifications
Rated Service Flow 

-0.75 US gpm / 2.8 Lpm 

Cartridge Life: 

CF2 cartridge - up to 6 months or 750 gal (2838L)

MAXIMUM PRESSURE 

-100 psi / 690 kPa               

MAXIMUM TEMPERATURE 

 -100°F / 38°C.