Salt Setting (lbs/cu ft) 

Model 

6.0 

8.0 

10.0 

12.0 

15.0 

30T 

2.9 

3.8 

4.8 

5.7 

7.1 

45T 

4.2 

5.7 

7.1 

8.5 

10.7 

60T 

5.7 

7.6 

9.6 

11.4 

14.2 

Table 1 : Refill time (in minutes) for various salt settings (or next whole number) 

 
STEP 7: Manual Regeneration 
 

If screen is locked, press “

 MENU” for 3 seconds to unlock. 

 To initiate an immediate regeneration, press the 

SET/REGEN

 

button for 3 seconds, an option for “

Delayed

” or “

Immediate

” regeneration will appear. Press the 

SET/REGEN

 button 

again  and  “

Delayed

”  will  begin  flashing.  Now  press  the  down  arrow  button  and  “

Immediate

”  will  flash.  Press  the 

SET/REGEN

 button once and then press the menu button once. Valve will immediately start manual regeneration.  

 
YOUR UNIT IS NOW READY FOR SERVICE 

 
 

 

Parameter 

Option 1 

Option 2 

Option 3 

Option 4 

Comments 

System Language 

English 

Spanish 

French 

 

Set to French if desired. Spanish not 
enabled 

Valve Operation 

Softener 

Filter 

Iron 

Filter 

 

Leave at default setting 

Regeneration 
Mode 

Meter 

Delayed 

Meter 

Override 

Calendar 

Clock 

Meter 

Immediate 

Leave at default setting 

Regeneration Time 

2:00 AM 

 

 

 

The unit is factory set to regenerate at 2:00 
AM on the day of regeneration. You can 
change to another time if desired. 

Capacity 
Calculation 

Automatic 

Manual 

 

 

Automatic (recommended). Change to 
manual settings if desired. 

Resin Volume 

For 30T unit, set resin volume at 1.0 cu ft 
For 45T unit, set resin volume at 1.5 cu ft 
For 60C unit, set resin volume at 2.0 cu ft 

Salt Setting 

Leave at default setting for maximum efficiency. (Defaults – 30T = 

6.0

, 45T=

9.0

, 60C=

12

Set at 15 lb/ft³ for maximum capacity 

Note: 

Capacity = Amount of water that can be softened between regenerations. Capacity reduces 

when salt setting is reduced, but salt consumption efficiency increases. 

Refill Flow Rate 

0.7 GPM 

 

 

 

Leave at default setting 

Unit Capacity 

For 30T, default = 20,000 at 6lbs/ft³. Set at 30,000 grains if you chose 15 lbs salt/ft³ in step7 
For 45T, default = 30,000 at 9lbs/ft³. Set at 45,000 grains if you chose 15 lbs salt/ft³ in step7 
For 60T, default = 40,000 at 12lbs/ft³. Set at 60,000 grains if you chose 15 lbs salt/ft³ in step7 

10 

Reserve Capacity 

75 

gal/person 

 

 

 

Increase or decrease value as desired 

11 

Capacity 

This will be the calculated unit capacity in US Gal. The unit will regenerate only when this much 
water has been used. 

12 

Backwash 

05 

 

 

 

Increase to 10 if water has lot of dirt or rust 

13 

Brine / Rinse 

50 

 

 

 

Increase to 60 if water is more than 15 
grains hard 

14 

Rapid Rinse 

 

 

 

Increase to 10  if you want a longer rinse 
time after regeneration 

15 

Refill 

For REFILL settings based on your chosen salt settings, please refer to 

Table 1 

below 

16 

Restore Default 

NO 

 

 

 

Leave at default. Change only if you would like 
to re-start programming from the beginning 

Содержание 30T

Страница 1: ...be resolved over the phone Help Line 1 800 667 8072 Monday to Friday 8 30 AM to 5 00 PM EAST Website www rainfresh ca TABLE OF CONTENTS System Specifications 2 How Your Water Conditioner Works 2 Caut...

Страница 2: ...mum pressure rating Do not install on water that is microbiologically unsafe without adequate disinfection before or after the unit For effective disinfection install a Rainfresh Drinking Water System...

Страница 3: ...from possible freezing conditions The softener can sit directly on the floor and will not corrode DO NOT set the softener or salt tank onto make shift platforms as this can cause damage or may cause i...

Страница 4: ...appropriate slot at the bottom of the salt tank fig 5A Slide the 3 8 tube through the hole on the side of the salt tank and connect it to the brine float as shown in fig 6A Attach the other end of th...

Страница 5: ...ming sets valve operational settings if required LEVEL 1 USER PROGRAMMING STEP 1 Setting Current Time Press MENU for 3 seconds to unlock screen Press MENU again and the hour value becomes highlighted...

Страница 6: ...Programming The following chart indicates choices and default settings Note Default settings are indicated in bold letters Use same programming method as you used in level 1 to advance and or change...

Страница 7: ...o manual settings if desired 6 Resin Volume For 30T unit set resin volume at 1 0 cu ft For 45T unit set resin volume at 1 5 cu ft For 60C unit set resin volume at 2 0 cu ft 7 Salt Setting Leave at def...

Страница 8: ...and fill only to the height of the brine well The salt tank should never be empty Prevent Salt Bridging Humidity or wrong type of salt may create a cavity between the water and the salt This action kn...

Страница 9: ...and add resin cleaner to clean bed Increase regeneration frequency 3 Inlet of control plugged due to foreign materal Remove piston and clean control valve 1 Air in water system Check well system for...

Страница 10: ...nd is intended to exclude any liability on the part of Envirogard for any incidental damages consequential damages labour charges or any other costs incurred in connection with the purchase installati...

Отзывы: