RainFlo Multi-Stage Centrifugal Pumps

Model No.

MHP50

MHP75

MHP150

Horsepower

½

¾

1

½

Nominal voltage range

110-125 

VAC, 60Hz, 

8

A max.

110-125 

VAC, 60Hz, 

12

A max.

110-125 

VAC, 60Hz, 

14

A max.

Impeller stages

2

4

4

Maximum flow (

0 Head)

17.6 GPM

26 GPM

36 GPM

GPM at 60 PSI

N/A

9.2

12

GPM at 50 PSI

N/A

14

19.5

GPM at 30 PSI

9

20

28.5

Maximum head

79

 ft.

164

 ft.

168

 ft.

System pressure

up to 34 PSI

up to 65 PSI

up to 65 PSI

Inlet pressure

up to 45 PSI

up to 45 PSI

up to 45 PSI

Inlet/outlet size

1

”FNPT/

 

1”FNPT

1

”FNPT/

 

1”FNPT

1

¼” FNPT/

 

1” FNPT

Weight

19.65 lbs.

22 lbs.

25.5 lbs.

Dimensions

15.75

”L x 

6.5

”W x 

9”H

15.75

”L x 

6.5

”W x 

9”H

16

”L x 

6.5”W 

9.3”H

Thermal protection

yes

yes

yes

Operating liquid temp

32

°-

140

°

F

32

°-

140

°

F

32

°-

140

°

F

Max. environmental temp

122

°F

122

°F

122

°F

Motor

2-pole 

induction, 

continuous 

duty

2-pole 

induction, 

continuous 

duty

2-pole 

induction, 

continuous 

duty

RPM

3450

3450

3450

Cooling

Air cooled

Air cooled

Air cooled

Insulation class

F

F

F

Protection

IP55

IP55

IP55

Certifications

TUV, CCC

TUV, CCC

TUV, CCC

Warranty

1 year

1 year

1 year

 

Содержание MHP50

Страница 1: ...MHP50 MHP75 MHP150 USER MANUAL...

Страница 2: ...It is the installer s responsibility to read understand and comply with these instructions...

Страница 3: ...tions requirements Optionally for added ease of use the pump may be paired with an aux iliary pump controller RainFlo PC115A for on off functions and run dry protection Please Note This appliance is o...

Страница 4: ...e intended for use in pumping circulating and boosting water industrial fluids and other weak chemical industrial mediums Rainwater harvesting systems Greywater systems Water treatment processes Water...

Страница 5: ...n damage the product Before proceeding with installation make sure the unit shows no visible signs of damage Mounting Location The pump must be mounted in a horizontal orientation and must be mounted...

Страница 6: ...ns should always be made by a qualified electrician Extra care should be taken to verify that all components are properly grounded NOTICE This pump must be primed prior to first use Priming Procedure...

Страница 7: ...ure up to 45 PSI up to 45 PSI up to 45 PSI Inlet outlet size 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT 1 FNPT Weight 19 65 lbs 22 lbs 25 5 lbs Dimensions 15 75 L x 6 5 W x 9 H 15 75 L x 6 5 W x 9 H 16 L x 6...

Страница 8: ...0 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 Hft RainFlo MHP50 RainFlo MHP75 RainFlo MHP150 10 PERFORMANCE CHARTS RainFlo MHP50 Performance Chart TDH PSI GPM 79 34 3 5 77 33 5 74 32...

Страница 9: ...0 104 45 15 8 92 40 17 0 81 35 18 8 69 30 20 2 58 25 21 4 46 20 22 7 35 15 24 0 23 10 25 0 13 5 5 26 2 RainFlo MHP150 Performance Chart TDH PSI GPM 160 68 2 139 60 12 127 55 15 2 116 50 19 3 104 45 2...

Страница 10: ...isn t too high Verify the suction head is in water Prime the pump The pump runs but no water Check the suction side intake connection and ensure it is not blocked or damaged If so clean or replace the...

Страница 11: ...9...

Страница 12: ...RainHarvest Systems RainHarvest com 800 654 9283 030524...

Отзывы: