![Rainbow Treecare IQ TREE INFUSER Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/rainbow-treecare/iq-tree-infuser/iq-tree-infuser_application-manual_3440218003.webp)
1.
2.
3.
4.
1.
2.
3.
4.
5.
INJECTING
CLEANING
As with all injection devices, refer to the product label
for dose rates and number of injection sites to drill.
Drill the required number of
injection sites into the root flare
Use a 15/64” high helix drill bit. Refer
to the product label for number of
injection sites. Injection sites should
be uniformly spaced around the tree.
Insert the tip of the
dispensing gun into the first
injection site
NOTE:
You want to go in as far as
possible to create a tight seal
around the tip. Turning the gun
slightly while you firmly press
the tip into the hole will help
create a tight seal.
Holding down the safety lock, pull the
dispensing gun trigger
NOTE:
As the iQ Tree Infuser™ is injecting, the red LED
indicator on the gun will be on.
Do not pull the gun
out while the red light is on
or chemical may leak.
When red light has
gone off, the dose
has been delivered
to the injection site
Remove the gun with-
out pulling the trigger
and inject the next hole.
The display will show
the PSI while injecting.
NOTE:
If an injection is particularly slow, you do have
the option to stop an injection by pressing the green
Start/Reset
button on keypad. This will stop the
system from continuing to try to inject the hole. Wait
for the red LED light on the gun to go off before
removing the gun.
5.
Continue injecting until the Dose
Remaining is 0
When it reaches zero, you are now done.
Select
Prime/Clean Mode
Turn the main line valve to A
(Air)
If you are done injecting for the day:
unscrew the
product bottle from the iQ Tree Infuser™ and replace it
with an isopropyl alcohol-based cleaning solution and
repeat steps 1-5 for priming the unit.
NOTE:
For questions on cleaning solution options, call our
Solution Center at 1-877-272-6747.
Insert the tip of the dispensing gun into the cap
of the product bottle
Hold down the safety lock and pull trigger until your
lines are emptied of fluid. You can visually inspect the
lines to make sure that the fluid has been emptied.
Purge the cleaning solution
by turning
the main line valve back to A (Air) and
dispense the fluid back into the bottle. Now
the iQ Tree Infuser™ is clean.
III.
IV.
Drill 1”
past bark
6.
Turn the main line valve to F
(Fluid) and
insert the gun tip into the cap. Run the
cleaning solution through the system.
™