background image

9

Watering Issues

Problem

Possible Cause

Possible Solution

Automatic and manual 

cycles do not begin 

watering.

Water source not supplying 

water.

Verify the main water and all supply lines are open and operating properly.

Wires not properly connected.

Verify field wires are connected properly including the timer, master valve (or pump start relay) 

and any spliced connections.

Wires damaged or corroded.

Check field wiring for damage and replace if necessary. Check all connections and replace with 

watertight connectors as needed.

Dial not set to AUTO RUN 

position.

Verify the dial is in the AUTO RUN position.

An installed Rain Sensor may 

be activated.

Operation will resume when sensor dries out. To test operation, disconnect the Sensor and con-

nect a jumper wire between the Rain Sensor terminals.

If no Rain Sensor is installed, 

the jumper wire may be 

damaged or missing.

Connect the two yellow Rain Sensor terminals with a short length of 14 to 18 gauge jumper wire.

An electrical surge may 

have damaged the timer’s 

electronics.

Press the RESET button under the wiring bay cover. If there is no permanent damage, the timer 

should resume normal operation. Note: date and time must be re-entered after reset.

Watering cycles do not 

shut off.

Debris trapped in valve.

Flush the valve by temporarily opening the dump hole and re-tighten. 

Electrical Issues

Problem

Possible Cause

Possible Solution

LCD Display is blank.

Timer is not receiving power.

Verify the power cord is connected and securely plugged in. (indoor)
Verify the transformer is wired correctly and the circuit breaker is on. (outdoor)

No red LED light (indoor).

Blown transformer.

Replace transformer.

LCD Display is “frozen” 

and timer will not accept 

programming.

An electrical surge may 

have damaged the timer’s 

electronics.

Disconnect power to the timer for 3 minutes then turn back on. If there is no damage, the timer 

will accept programming and resume normal operation.

Valve short error message 

on LCD display.

Wires damaged or corroded.

Check the indicated zone wiring for damage and replace if necessary. Check all connections and 

replace with watertight connectors as needed.

Troubleshooting

Rain+Birdt

Rain Bird Corporation

6991 East Southpoint Road

Tucson, AZ 85756 USA

Tel: (520) 741-6100

Fax: (520) 741-6522

2015 Rain Bird Corporation

t

Registered trademark of Rain Bird Corporation

Questions? Call 1-800- RAIN BIRD (800-724-6247) 

or visit www.rainbird.com

P/N: 640296-01 (ENG) Rev. 10/15

Содержание SST-900i

Страница 1: ...ay 8 Seasonal Adjust 8 Error Detected 8 Manual Operation 8 Water All Zones 8 Water One Zone 8 Troubleshooting 9 Watering Issues 9 Electrical Issues 9 Installation 2 Tools and Supplies Needed 2 Step 1...

Страница 2: ...unit and drive a screw through the center hole as shown use the supplied wall anchors if necessary 1 8 GAP SCREW INDOOR MODEL SHOWN Step 2 Connect Power c c WARNING DO NOT plug in or apply power to t...

Страница 3: ...the field Connect a color coded wire from the direct burial cable to either wire on the valve Connect the remaining wire on each valve to a common wire which then connects to the timer NOTE Use water...

Страница 4: ...n main power supply or plug the power cord into a waterproof receptacle NOTE Do not plug the timer into a socket that is con trolled by a secondary ON OFF light switch or GFI outlet Test Watering Turn...

Страница 5: ...y at the water source Using a direct burial cable connect one of the wires from the master valve or pump start relay to the timer termi nal marked MSTR VALVE Using a direct burial cable connect the re...

Страница 6: ...DOWN ARROWS Use UP DOWN arrows on left or right keys to set clock date run time etc AUTO RUN Set dial here to run all pro grammed settings OFF Turns off all watering RAIN DELAY Delays watering up to...

Страница 7: ...blue WATERING TIMES PER DAY buttons to select the number of times per day to water WATERING DAYS WATERING TIMES PER DAY SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY ZONE OFF ONE TIME TWO...

Страница 8: ...ining Current Time Seasonal Adjust Screen displays the percentage adjust ment for all zones All Durations Adjusted Season Adjust Error Detected If an error is detected the affected zone is displayed E...

Страница 9: ...timer should resume normal operation Note date and time must be re entered after reset Watering cycles do not shut off Debris trapped in valve Flush the valve by temporarily opening the dump hole and...