Rain Bird RC2-230V Скачать руководство пользователя страница 2

CONNECT

120 VAC

RESET

ACCESSORY

1 2 3 4 5 6 7 8

24VAC

SEN S

C M

AUTO

OFF

MANUAL

NEXT

STATUS

24VAC SENS

C M

CONNECT

120  VAC

RESET

ACCESSORY

1 2 3 4 5 6 7 8

24VAC

SEN S

C M

AUTO

OFF

MANUAL

NEXT

STATUS

EN

ENGLISH

3.2 mm

2

4

1

CONNECT

120 VAC

RESET

ACCESSORY

1 2 3 4 5 6 7 8

24VAC

SENS

C M

AUTO

OFF

MANUAL

NEXT

STATUS

CONNECT

120  VAC

RESET

ACCESSORY

1 2 3 4 5 6 7 8

24VAC

SEN S

C M

AUTO

OFF

MANUAL

NEXT

STATUS

CONNECT

120  VA C

RESE T

ACCESSORY

1 2 3 4 5 6 7 8

24VAC

SEN S

C M

9 10 11 12

MASTER 
VALVE

C

MV

1

2

S

AUTO

OFF

MANUAL

NEXT

STATUS

2

1

2

Feature Description

Maximum zones

 8

Automatic programs

 3

Start times per program

 4

Custom run days

 Yes

Master valve control

 Yes

Rain delay

 Yes

Rain/freeze sensor control

 Yes

Seasonal adjust

 Yes

Manual zone run

 Yes

Manual program run

 Yes

Manual test all zones

 Yes

Zone advance

 Yes

Built-in WiFi

 Yes

AP Hotspot

 Yes

WiFi Smart Controller  User Manual

Installation

 

If You’re Replacing an Existing Controller

1.

 Take a photo of the wiring details, which will be useful to reference when installing the 

new controller.

2.

 Unplug the power cord from the AC power outlet and disconnect wires from the 

controller. 

Mount New Controller

1.

 Choose a mounting location on a wall at least 4.5 m away from major appliances or 

air conditioners. Ensure an AC power outlet is within close proximity to mounting 

location. 

 

 WARNING

Install the controller with the power supply cord exit side pointing downwards to avoid 

ingress of water.

2.

 Drive a mounting screw into the wall, leaving 

a 3.2 mm gap between the screw head and 

the wall surface (use supplied wall anchors if 

necessary).

3.

 Locate the keyhole slot on back of the 

controller and hang it securely on the 

mounting screw.

4.

 Remove the wire bay cover on the lower part 

of the controller and drive a second screw 

through the open hole and into the wall (use 

supplied wall anchors if necessary).

Connect Valve Wiring 

1.

 With the wire bay cover removed, route all field 

wires through the opening at the bottom of the 

controller.

 

 WARNING

DO NOT route valve wires through the same opening as power wires.

2.

 Connect one wire from each valve to one of the numbered zone terminals (1–8) on  

the controller.

NOTICE

DO NOT connect more than one valve to the same zone terminal (1–8).

3.

 Connect a field common wire to the common terminal (C) on the controller.

4.

 For connection of optional 

accessories (rain or rain/freeze 

sensor, master valve, pump start 

relay), refer to the appropriate 

section within this manual. 

Connect Fixed Wiring  

 

 WARNING

• Ensure that AC power is disconnected before replacing wiring.

• The installation must prevent the connection to be strained.

• When using fixed wiring to main supply, the installation must incorporate a 

disconnection device.

• DO NOT apply power until you have completed and checked all wiring connections.

• DO NOT attempt to link two or more controllers together using a single transformer.

1.

 FOR MODEL RC2-AUS, ARC8-AUS and ARC8-230V: If desired, the provided power cord 

can be removed and replaced with custom wiring.

2.

 Remove the wire bay cover on the lower part of the controller.

3.

 Locate the transformer box in the left-hand corner  of the wire bay and unscrew the 

wiring compartment cover.

4.

 FOR MODEL RC2-AUS, ARC8-AUS and ARC8-230V: Unscrew the terminal block 

connecting the AC power cord and the transformer wires. Remove the power cord 

wires from the transformer box.

5.

 FOR MODEL RC2-AUS, ARC8-AUS and ARC8-230V: Remove the factory installed power 

cord by loosening the liquid tight cord connector.

6.

 Route the three wires from an external power source into the wiring compartment.

7.

 Connect the external power supply wires using the terminal block and resecure the 

liquid tight cord connector or a means of strain-relief of connections.

Power Wiring Connections  230 V

  

• Brown supply wire (live) to the brown transformer wire.

• Blue supply wire (neutral) to the blue transformer wire.

• Green/yellow supply wire (ground) to green/yellow transformer wire.

Connect Rain/Freeze Sensor (optional) 

NOTICE

• DO NOT remove the jumper wire unless 

connecting a rain or rain/freeze sensor. 

The controller will not function if the 

jumper wire is removed and a rain or 

rain/freeze sensor is not connected.

• Rain Bird controllers are only compatible 

with normally closed rain or rain/freeze 

sensors.

• Check local and/or state regulations to 

determine if a rain or rain/freeze sensor 

is required.

1.

 Remove the yellow jumper wire from the 

SENS terminals on the controller.

2.

 Connect both rain or rain/freeze sensor 

wires to the SENS terminals.

3.

 For detailed installation and operation of 

rain or rain/freeze sensor, refer to sensor 

manufacturer’s installation instructions.

Connect Master Valve (optional)   

 

 WARNING

DO NOT route the master valve wires through the same opening as the power wires.

1.

 Using a direct burial cable, connect one of the  wires from the master valve to the 

master valve terminal (M).

NOTICE

DO NOT connect more than one valve to the master valve terminal (M).

2.

 Connect the remaining wire from the master valve to the common terminal (C).

rain-bird.com.ua

Содержание RC2-230V

Страница 1: ...H Pg 2 ES ESPA OL Pg 5 FR FRAN AIS Pg 8 DE DEUTSCH Pg 11 IT ITALIANO Pg 14 PL POLSKIE Pg 17 RU Pg 20 PT PORTUGU S Pg 23 TU T RK Pg 26 CN Pg 29 AR Pg 32 NL NEDERLANDS Pg 35 IW Pg 38 CS E TINA Pg 41 AUT...

Страница 2: ...refer to the appropriate section within this manual Connect Fixed Wiring WARNING Ensure that AC power is disconnected before replacing wiring The installation must prevent the connection to be strain...

Страница 3: ...Download and launch the Rain Bird App 2 SET PROGRAM START TIME S This controller is scheduled using up to four independent start times per program The start time s is the time of day at which the prog...

Страница 4: ...alled to provide a separation distance of at least 20 cm from all persons and must not be co located or operating in conjunction with any other antenna or transmitter NOTICE Changes or modifications n...

Страница 5: ...C SENS C M AUTO OFF MANUAL NEXT STATUS CONNECT 120 VAC RESET ACCESSORY 1 2 3 4 5 6 7 8 24VAC SEN S C M AUTO OFF MANUAL NEXT STATUS 2 1 CONNECT 120 VA C RESE T ACCESSORY 1 2 3 4 5 6 7 8 24VAC SEN S C M...

Страница 6: ...WiFi WiFi WiFi WiFi Rain Bird AP Hotspot AP Hotspot 1 A B C Rain Bird PGM 1 M 2 C 3 4 230 24 Rain Bird 1 WiFi 2 Rain Bird Rain Bird 2 Rain Bird 3 Rain Bird Odd Even Custom Cyclic 4 Rain Bird WiFi 100...

Страница 7: ...8 22 AP Hotspot WiFi RC2 AUS ARC8 AUS ARC8 230V 1 8 STATUS STATUS STATUS WiFi STATUS AUTO OFF MANUAL RC2 AUS ARC8 AUS ARC8 230V 20 Rain Bird Rain Bird 2500 B Rain Bird WiFi Rain Bird 1 800 RAIN BIRD 8...

Отзывы: