background image

 

 

D37567

 

 

IC-TFU Specifications & Compliance

 

Operating Temperature: 

 

 

14ºF to 125ºF (-10ºC to 51ºC) 

Storage Temperature:  

 

 

-40ºF to 150ºF (-40ºC to 65.5ºC) 

Operating Humidity:   

 

 

75% max at 40ºF to 108ºF (4.4ºC to 42.2ºC) 

Storage Humidity: 

 

 

 

75% max at 40ºF to 108ºF (4.4ºC to 42.2ºC) 

IC System

TM

 Field Wiring Voltage 

 

26-28 VAC (max) 

 

    

 

SOLENOID 

CONTROLLER 

273J 

 

 

 

This device complies with Part 15 of the FCC rules subject to the following 

two conditions: 

(1)

 

This device may not cause harmful interference, and 

(2)

 

This device must accept any interference received, including 

interference that may cause undesired operation. 

This Class B digital apparatus meets all requirements of the Canadian 

Interference Causing Equipment Regulations. 

 

 

 

EN61000-6-1 (1997) Class B: 

 

EN61000-3-2 

 

EN61000-3-3 

EN61000-6-3 (1996): 

 

EN61000-4-2 

 

EN61000-4-3 

 

EN61000-4-4 

 

EN61000-4-5 

 

EN61000-4-6 

 

EN61000-4-8 

 

EN61000-4-11 

 

EN 60335-1: 2010 Safety of household and similar electrical appliances 

Содержание IC-TFU

Страница 1: ...Rain Bird IC TFU Transition Field Upgrade Device Installation Guide CONNECT to convert...

Страница 2: ...l Control Software 6 Choose Location to Install the IC TFU 7 Gather Installation Tools Other Materials Required 7 Installation Step 1 Connect IC TFU Output wires to a DC Latching Solenoid 8 Installati...

Страница 3: ...omponents can be found on the Rain Bird IC System website at https www rainbird com products ic rotors valves https www rainbird com golf products ic system Reference Documents Rain Bird IC System Wir...

Страница 4: ...fter the wire path has been powered before attempting any operation with the IC TFU device WARNING Field wire paths must be kept separate from other wire paths Do not connect the field wires together...

Страница 5: ...ed for each step Verify Compatible Rain Bird Central Control Software is Installed Choose a location to install the IC TFU Gather Installation Tools Other Materials Required Install IC TFU o Step 1 Co...

Страница 6: ...II or Stratus LT in use is version 8 1 0 or higher 2 Open the Central Control software and click on the Rain Bird icon in the front office 3 If the software version is less than 8 1 0 as viewed below...

Страница 7: ...box as the connected valve 2 Choose a location with easy access to the MAXI wire path 3 The IC TFU device should be housed in an accessible valve box with proper drainage whenever possible 4 Take cau...

Страница 8: ...atching solenoids 1 Strip approximately 1 of insulation from each DC Latching Solenoid connection wire to be spliced with IC TFU output control wires Take care not to score copper conductors 2 Splice...

Страница 9: ...tors a Secure each splice with a wire nut Figure 2 b Insert the splice and wire nut completely into the grease cap Figure 3 i If required use a thin object to push the wire nut to the end of the greas...

Страница 10: ...1 of insulation from each MAXI wire IC SystemTM field wiring to be spliced with IC TFU Take care not to score copper conductor 4 Splice join wires by wrapping IC TFU wires around MAXI wires Figure 5...

Страница 11: ...cure each splice with a wire nut Figure 5 b Insert the splice and wire nut completely into the grease cap Figure 6 i If required use a thin object such as an irrigation flag to push the wire nut to th...

Страница 12: ...ends are present 2 Remove address barcode from the IC TFU device by tearing at perforated line keep this barcode for your records 3 Assure that all connections are suitably protected from surrounding...

Страница 13: ...D37567 4 Apply power to the IC SystemTM wire path a Allow two 2 minutes for all IC SystemTM devices on the wire path to power up before performing operations Figure 8...

Страница 14: ...https www rainbird com products ic rotors valves 2 Activate Rain Bird Central Control software version 8 1 0 or higher on the central control pc and select System Settings to check the Integrated Con...

Страница 15: ...15 of the FCC rules subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cau...

Страница 16: ...9778 U S and Canada only Specification Hotline 800 458 3005 U S and Canada only Rain Bird Corporation 970 W Sierra Madre Avenue Azusa CA 91702 U S A Phone 626 812 3400 Fax 626 812 3411 Rain Bird Inte...

Отзывы: