Rain Bird IC System Скачать руководство пользователя страница 8

 

IC System

TM

 Design Guide, v2.3 

 

How the system works 

The IC System

TM

 uses a data transfer method that sends packets of information across a two-wire path. 

Each ICM has a unique address that allows the central control software to communicate with each ICM 

individually.  

The  ICM  has  a  unique  “Long  Address”  pre-assigned  from  the  factory  that  identifies  it  in  the  central 

control software.  The Long Address is like having a phone number for each ICM.  Each ICM has a label 

on the outside of the housing with a barcode and the printed Long Address.  The user must enter the 

Long Address into the central control software at initial start-up.  

The central control software communicates with the ICMs in the field through a high-speed method of 

communication  that  requires  that  each  ICM  is  assigned  a  Fast  Connect  Address.    The  Fast  Connect 

Address  is  assigned  automatically  by  the  central  control  software  based  on  its  location  in  the  Central 

Control Database.  

 

The Fast Connect Address is a method by which the Central Control Software can quickly communicate 

with  more  than  one  ICM  at  a  time.    This  is  like  having  a  speed  dial  for  a  phone  number.    The  Central 

Control  Software  can  manage  up  to  750  ICMs  on  a  single  wire  path  by  utilizing  this  communication 

scheme. 

 

Содержание IC System

Страница 1: ...IC SystemTM Design Guide v 2 3 Updated August 2016...

Страница 2: ...of the IC Interface ICI 6 Uninterruptable Power Supply UPS 7 How the System Works 8 Basic Design Data 9 System Capacity 10 Flexible Design 10 Wire Path 11 Wire Sizing Charts 12 Examples 13 15 Groundin...

Страница 3: ...the proper design for the specific application IC System Product Definitions Central Control Software CirrusTM Nimbus IITM Stratus IITM and Stratus LTTM are the Central Control applications that are a...

Страница 4: ...nterface ICI is the electronic hardware and firmware that accepts commands from the Central Control Software and directs them to the field The ICI also communicates intelligently with the field in ord...

Страница 5: ...ware via Rain Bird MAXITM cable two wire path and the ICI interface The central control software automatically operates the rotors and valves throughout the golf course by activating each individual I...

Страница 6: ...PU Board The CPU Board provides communication between the Central Control Computer and each of the wire paths Driver Board The Driver Board provides communication between the CPU board and the ICMs in...

Страница 7: ...r the IC System Different countries may have differing requirements and APC typically makes a Smart UPS for each country according to the needs of that country If sourcing a Smart UPS for a different...

Страница 8: ...ed Long Address The user must enter the Long Address into the central control software at initial start up The central control software communicates with the ICMs in the field through a high speed met...

Страница 9: ...has a maximum capacity of two 2 wire path inputs 4 A single Driver Board has a maximum capacity of 1 500 stations when both wire paths are used 5 The ICI has a maximum capacity of 3 000 stations when...

Страница 10: ...h 12 ICIs Standard configuration is number of stations and ICIs available in the software without purchasing a Hybrid Software Module ICIs are purchased separately as needed and are not included with...

Страница 11: ...provide the proper guidelines for wire sizing on the wire path The most important calculation is that of the primary Trunk wire length on each wire path The Trunk wire length is considered to be the l...

Страница 12: ...2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 100 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 150 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm 2 2 5mm...

Страница 13: ...l be up to 10 000 feet 3 000 meters Utilizing the sizing chart the Trunk wire should use 14 AWG 2 5 mm2 MAXITM wire for the installation Although there are multiple branches off of the main Trunk wire...

Страница 14: ...rt the Trunk wire should be designed using 12 AWG 4 0 mm2 wire NOTE 12 AWG 4 0 mm2 wire will be used for the Trunk wire only 14 AWG 2 5 mm2 wire can be used for all branch lines as long as each branch...

Страница 15: ...MAXITM wire for the installation As the initial 3 500 feet 1 067 meters is greater than 2 500 feet it requires an increase in wire size to 12 AWG 4 0mm2 The initial 3 500 feet 1 067 meters of Trunk wi...

Страница 16: ...there are no ICMs an ICSD is not required every 500 feet 150 meters For example if there is a wire length run of 2 000 feet 609 meters between ICMs an ISCD should be installed immediately after the l...

Страница 17: ...vide a good earth ground at the ICSD A measurement with the shield connected does not give a true reading of the individual ground location at the ICSD and will give a reading that is considerably low...

Страница 18: ...oting will be more difficult so looping is not recommended Combining Wire Paths at the Interface While a single IC wire path can easily handle 750 ICMs when sized according to the design guide table t...

Страница 19: ...communication between the central control computer and the remotely located ICI The MRLK900 Kit includes two radios that operate in the 902 928MHz range and automatically hop between frequencies to av...

Страница 20: ...20 IC SystemTM Design Guide v2 3...

Страница 21: ...IC SystemTM Design Guide v2 3 21...

Отзывы: