ESP-LXIVM Controller Troubleshooting Guide

Table of 

Contents

Category

Issue

Potential 

Cause

Solution

Simul 

Stations 

(Simul- 

taneous 

Station 

Operation)

Too many 

or too few 

stations are 

operating 

simultaneously 

when 

program(s) 

operate.

LX-IVM 

(Controller) 

SimulStations 

are configured 

incorrectly.

Turn dial to 2-wire Setting / Advanced / 

SimulStations. Select LX-IVM SimulStations 

and adjust the maximum number of 

simultaneous irrigation stations you want to 

allow to operate across all programs at any 

time. Non- Irrigation SimulStations control 

stations with Non-Irr Priority.

PGM (Program) 

SimulStations 

are configured 

incorrectly.

Turn dial to 2-wire Setting / Advanced 

SimulStations. Select PGM SimulStations 

and adjust the maximum number of 

simultaneous irrigation stations you want 

to allow to operate simultaneously within 

the currently selected program. Move 

the Program Button to select the other 

programs 1 - 40.

Weather 

Sensors

Weather 

sensor is not 

preventing 

controller 

manual 

operation.

This is by 

design.

Manual station, program or test program 

operation (from the front panel or a remote) 

is allowed regardless of the weather sensor 

state. To see the current state of a weather 

sensor, turn the dial to Weather Sensors. The 

status of each sensor is displayed.

Wireless 

weather 

sensor is not 

providing 

input to the 

controller.

Sensor receiver 

is not wired to 

the controller 

module 

correctly.

The IVM 2-Wire Interface Module includes 

4 terminals for wireless weather sensor 

connections. Wiring connections should be 

made as follows:
•  Sensor receiver power wires to + and – 

terminals.

•  Sensor receiver sensor wires to Sen and 

C terminals.

Controller 

Knock-

outs

I am having 

trouble 

removing the 

knock-outs 

on the 

ESP-LX Series 

Controller 

plastic cabinet.

Unlike knock-

outs on a metal 

enclosure, 

these plastic 

knock-outs are 

designed to be 

removed by 

applying force 

to the center at 

the dimple.

Prior to installing the cabinet, place on a flat 

surface with the knock-out facing up. Locate 

the dimple in the center of the knock-out 

you wish to remove. Place the tip of a large 

Phillips screwdriver in the dimple. Use a 

rubber or wooden mallet to firmly strike 

the top of the screwdriver. The knock-out 

should pop out in a single piece. If it breaks, 

use pliers to remove the pieces. Do not use a 

flat-bladed screwdriver around the outside 

of the knock-out as this could crack the case.

Содержание ESP-LXIVM

Страница 1: ...ESP LXIVM Controller Troubleshooting Guide...

Страница 2: ...e visit www rainbird com esplxivm For free professional support for programming and troubleshooting please call 1 866 544 1406 Local Rain Bird Contact Information Distributor Mgr Email Phone Area Spec...

Страница 3: ...res 6 Front Panel 6 2 Wire Settings 7 Diagnostics 7 Cabinet Components 8 Basic Programming 9 Troubleshooting Flow Charts 10 Getting Started 10 2 Wire Mapping 11 No Water Days No Run Times 13 Shorted P...

Страница 4: ...37 2 Wire Path Status 37 Individual Path Status 37 Tools Recommended MAXI Cable 2 Wire communications cable Rain Bird WC20 splice kits for ALL electrical wiring connections Rain Bird genuine Wire Stri...

Страница 5: ...ves connecting and troubleshooting can be found here PGA Series https www rainbird com products pga series PEB Series https www rainbird com products pebpesb series EFB CP Series https www rainbird co...

Страница 6: ...Controller Troubleshooting Guide Table of Contents Controller Features Front Panel PROGRAMMING DIAL BACK BUTTON PROGRAM SELECT BUTTON DISPLAY PROGRAMMING KEYS ALARM LIGHT INFORMATION BUTTON LANGUAGE S...

Страница 7: ...7 ESP LXIVM Controller Troubleshooting Guide Table of Contents 2 Wire Settings Diagnostics...

Страница 8: ...8 ESP LXIVM Controller Troubleshooting Guide Table of Contents Cabinet Components TRANSFORMER JUNCTION BOX IVM 2 WIRE INTERFACE MODULE CONNECTOR...

Страница 9: ...up process It s most effective to use the 2 Wire Settings in the order they appear in the 2 Wire Settings menu as follows 1 Master Valves 2 Weather Sensors if present 3 Station Setup 4 Flow Sensors if...

Страница 10: ...4 1406 NoWater Days No RunTimes No StartTimes No PGM will More Exit Shorted Paths Duplicate Address Device Not Responding Flow Alarm END Job Well Done What does the screen display Is the LX IVM front...

Страница 11: ...tings screen press the Down Arrow key to select 2 Wire Mapping then press Next 2 At the 2 Wire Device Mapping screen press the and keys to set the desired hour from 0 to 23 then press the Right Arrow...

Страница 12: ...ping will begin Done Cancel The following pictures show the List Not responding screen without and with 2 wire mapping done Without 2 wire mapping With 2 wire mapping LIST NOT RESPONDING AT 01 01 18 T...

Страница 13: ...te Time and ensure time and date are correct Is the LX IVMsystem working Check the display for Alarms see page 10 Troubleshooting END Job Well Done NO YES Test LX IVM system using Manual Watering or A...

Страница 14: ...stics from the menu then press Next Press the Down Arrow button to select the Path 1 4 to test then press Next Next Page Press and hold the Yes button to energize the selected path Note Irrigation wil...

Страница 15: ...his indicates that the controller put the module in Short Finding Mode If there are more than one 2 wire paths connected disconnect the first 2 wire path Did the controller exit Short Finding Mode and...

Страница 16: ...ng new fence sign tree etc Wires damaged or found repairs of the Maxi Cable Repair damaged Maxi Cable using Maxi Cable and DRB Y connectors What does the display show Go back to Troubleshooting page 1...

Страница 17: ...alf of the 2 wire path The problem is downstream between this point and the end of the 2 wire path Re connect the 2 wire path and go to an IVM device approx 50 between this point and the end of the 2...

Страница 18: ...Quantity of other IVM SEN X 6 mA Approximate total system amperage in mA If there is a mismatch follow a process similar to page 10 to disconnect 50 of devices and redo calculation above Continue todi...

Страница 19: ...d to repeat this process until all of the duplicates have been addressed Test LX IVM system using Manual Run or Auto Run Check the display for Alarms see page 10 Trouble shooting END Job Well Done NO...

Страница 20: ...xceed your High or Low Flow settings Press the Down Arrow button to select Flow Alarms then press Next Turn the dial to Alarms History Press the Down Arrow button to select Station Flow Alarms then pr...

Страница 21: ...GO BACK TO PREVIOUS PAGE 20 Flow Alarms cont Check the Alarms screen to see if previous alarm cleared END Job Well Done Run all zones manually Alarm is cleared on the display NO YES After fixing any...

Страница 22: ...n press Ping The controller will ping the selected device and report a voltage reading if the device responds Interpreting Ping Results If the device does not respond verify the address and check the...

Страница 23: ...1 0 mA milliamp Wire tracing and fault finding equipment Spare system components and tools including spare IVM SOL IVM SEN device WC20 Splice Kits and wire strippers Total System Milliamp Draw Before...

Страница 24: ...the location of the 2 wire devices that are not responding and check all wire splices 2 Wire Path Diagnostics 1 Note the List Not Responding displays and corresponding wire paths If you notice that a...

Страница 25: ...check for signs of recent construction digging 3 Find a device location about half way down the 2 wire path cable Disconnect the splices See if the controller is still in Short Finding Mode If the Sho...

Страница 26: ...t a time from the controller IVM 2 Wire Interface Module Recheck the Control Output to isolate which segment of the 2 wire path has the ground fault 4 Find a device location about half way down the 2...

Страница 27: ...o connect to a LX IVM controller In the event a compatible DC latching solenoid is not available you can use the Rain Bird Pump Start Relay with following modifications to power the AC Solenoid 1 Conn...

Страница 28: ...ssistance with sourcing Choke and Capacitor Components VFD Filter Connection Connecting a VFD Pump in the same power circuit as the LX IVM Controller makes it prone to electrical noise having undesira...

Страница 29: ...ve been entered Note the duplicate Device Addresses posted in the alarm screen verify and enter the correct Device addresses Controller alarm Short Finding Mode 2 wire path is shorted and the controll...

Страница 30: ...tion Turn dial to Alarms History Flow Alarms and review the posted Station and or FloZone mainline flow alarms Note the station s or FloZone s that were identified If you configured FloWatch to Diagno...

Страница 31: ...e it is firmly connected to the backplane and front panel 2 Wire Path Issues Communication with 2 wire devices is intermittent 2 wire cable or splices are leaking to ground or between conductors Turn...

Страница 32: ...iple start times on an individual program In some cases users mix up start times and stations and can inadvertently program the system to start multiple times per day Water Windows have been configure...

Страница 33: ...ation for opening a valve solenoid The LX IVM Valve Types are preconfigured for Rain Bird commercial valve models Information for configuring Valve Types to work with other valves can be found in the...

Страница 34: ...porates an ice cube relay double relay system You can also add an ice cube relay to the existing pump start relay Contact Rain Bird Technical Services or Global Support Plan for relay model and wiring...

Страница 35: ...remote is allowed regardless of the weather sensor state To see the current state of a weather sensor turn the dial to Weather Sensors The status of each sensor is displayed Wireless weather sensor is...

Страница 36: ...ler Troubleshooting Guide Table of Contents IVM Interface Module This section explains the LED Status indicators on the IVM 2 Wire Interface Module LED Indicators MODULE STATUS 2 WIRE PATH STATUS 1 IN...

Страница 37: ...is the Normal up and running state Solid GREEN SHORT ADDRESS CONFIGURATION During the Normal state there are devices in the field that have not yet been programmed with short addresses All other norm...

Страница 38: ...essional Support Line at 1 866 544 1406 or else visit our web site at www rainbird com esplxseries Rain Bird Rewards www rainbird com rewards Phone 1 888 370 1814 Global Service Plan www rainbird com...

Отзывы: