16
Rain Bird ESP-LXD Controller Troubleshooting Guide
Table of
Contents
Short Finding Mode cont.
Alternatively, if you have a clamp meter you can also measure the
amperage:
NOTE:
Before measuring the amperage, calculate the
approximate current that the 2-wire path is consuming.
b
System Amperage Calculation
Quantity of single address station decoders
X
0.5 mA
+
Quantity of multiple address decoders
X
1.0 mA
+
Quantity of active decoders
X
17.5 mA
+
Quantity of other SD210 decoders
X
8.0 mA
=
Approximate total system amperage in mA
*
Single address station decoders include the FD-101 and FD-102 decoders
**
Multiple address station decoders include the FD-202, FD-401 and FD-601
decoders