Installation

Mount Controller

 

B

NOTE: Choose a suitable mounting location close 

to a 120VAC wall outlet.

Drive a mounting screw into the wall, leaving an 
1/8 inch gap between the screw head and the 
wall surface (use the supplied wall anchors if 
necessary), as shown.

Locate the keyhole slot on back of the controller 
unit and hang it securely on the mounting screw.

1/8 IN.

a

b

Open the front panel, and drive three additional 
screws through the open holes inside the 
controller and into the wall, as shown.

c

a

b

MASTER 
VALVE

COM

COM

MV

MV

11

22

SENS

SENS

e

c

Connect Valves

Route all field wires through the opening at the 
bottom or back of the unit. Attach conduit if 
desired, as shown.

 

C

WARNING

Do not route valve wires through the same opening 
as power wires.

Connect one wire from each valve to the terminal 
on the 

Base Module

 or 

Station Module

 that 

corresponds to the desired station number (1-22).

Connect a field common wire to the 

COM

 

(common)terminal on the 

Base Module

. Then 

connect the remaining wire from each valve to 
the field common wire, as shown.

To perform a Valve Test, connect the common wire 
to the 

COM

 terminal and the power wire to the 

VT 

terminal. This will immediately turn the valve ON.

Connect Master Valve (optional)

Connect a wire from the master valve to the 

MV

 

(master valve) terminal on the 

Base Module

Then connect the remaining wire from the master 
valve to the field common wire, as shown.

Содержание ESP-10ME3

Страница 1: ...LNKTM Ready ESP ME3 Controller Advanced User Manual...

Страница 2: ...The Intelligent Use of Water 3 ESP ME3 Controller Features 3 WiFi Enabled 3 Installation 4 Mount Controller 4 Connect Valves 4 Connect Master Valve optional 4 Connect Pump Start Relay optional 5 Conn...

Страница 3: ...lobal or by program Manual Watering Run Yes Manual Program Run Yes Manual Test All Stations Yes Short Detect Yes Delay Between Stations Set by program Accessory Port Yes 5 pin Save Restore Program min...

Страница 4: ...s through the opening at the bottom or back of the unit Attach conduit if desired as shown CWARNING Do not route valve wires through the same opening as power wires b Connect one wire from each valve...

Страница 5: ...ller CWARNING Do not route valve wires through the same open ing as power wires b Connect both flow sensor wires to the Flow terminals as shown Be sure to connect the positive sometimes red sensor wir...

Страница 6: ...rain freeze sensors refer to the sensor installation instructions b Connect Power CWARNING DO NOT plug in the transformer or connect external power until you have completed and checked all wiring conn...

Страница 7: ...erify that all wiring connections are secure then replace the wiring compartment cover and secure it with the screw a c b Station Expansion Modules Optional Station Modules can be installed in the emp...

Страница 8: ...the 20 is flash ing then there is no module installed for that station number Complete Controller Installation a Reinstall and reconnect the front panel b Apply power to the controller and test the sy...

Страница 9: ...le apps or LIMR when dial is in OFF position Display Indicators Display Func tion Description A L L ALL All stations C L E A R E D CLEARED Programming was cleared C Y C L I C CYCLIC Watering occurs at...

Страница 10: ...he dial to Run Times a Press Program Select to choose the desired Program if necessary b Press or to select a Station c Press or to set the RunTime for the selected Station d Press to set additional S...

Страница 11: ...rd 8 30 AM 1 15 MIN 2 15 MIN 3 15 MIN Correct Only one Start Time Program Letter Program Watering Time Program StartTime Station Number Station Watering Duration A 1st 8 00 AM 1 15 MIN 2 15 MIN 3 15 M...

Страница 12: ...gram Select to show program letter on the display b Press Program Select to choose the desired program if necessary c Press the Hold to Start button to begin watering the selected program d Turn the d...

Страница 13: ...crease Seasonal Adjust for all Programs Delay Watering Suspend watering for up to 14 days Turn the dial to AUTO a Press and Hold the button to enter the Rain Delay screen b Press or to set the DAYS RE...

Страница 14: ...ve by Station Allows a station to be controlled by a master valve or pump start relay Set to Odd or Even Watering Days Options Reset Button If the controller is not working properly you can try pressi...

Страница 15: ...ller has built in error detection that can automatically generate an ALARM caused by an essential programming error or if an electrical short condition is detected The ALARM LED light on the ESP ME3 c...

Страница 16: ...consider the interruption of irrigation due to rainfall as an alarm condition This is normal operation Flow Alarms Error ALARM LED Error Message On Display Flow Sensor High Flow Con dition Solid HIGH...

Страница 17: ...o see if the ALARM light on the controller is lit solid then repair or replace the valve if necessary Seasonal Adjust setting is too high Set Seasonal Adjust to 100 Electrical Issues solid LED illumin...

Страница 18: ...n NOTICE Use only Rain Bird approved accessory devices Unapproved devices may damage the controller and void the warranty For a list of compatible devices go to www rainbird com Changes or modificatio...

Страница 19: ...portugal rainbird eu www rainbird pt Rain Bird Corporation 970 W Sierra Madre Ave Azusa CA 91702 USA Tel 626 812 3400 Rain Bird Europe SNC Rain Bird France SNC 240 rue Ren Descartes B timent A parc Le...

Отзывы: