Rain Bird E-3 Скачать руководство пользователя страница 5

4

IV. SET WATERING START TIMES

2.

The program letter and “1” for Program Start
Time One appear.

2.

Set the time that you want the program to
start.

Note:

Remember, if you want all the stations on

the program to run only once each watering day,
enter only one start time for the program.

TO DELETE A START TIME

1.

Turn dial to 

START TIME

START TIME

.

2.

Press

  

SELECT PROGRAM

SELECT PROGRAM

.

You can repeat entire programs several times
each water day. Press 

ENTER

ENTER

 and repeat step

2. There are 6 program start times available.

3.

Repeatedly press ENTER
until the start time you want
to delete appears in the
display.

4.

Move the start time to the blank screen just
before midnight.

The E-Class controller automatically arranges
start times in the correct order. When a start
time is deleted, it’s empty gap is filled by the
next later start time.

5.

Turn the dial back to AUTO.

V. SET STATION RUN TIMES

In this step you decide how long each STATION
WILL RUN.

EXAMPLE:

STATION 2 will begin watering when station 1
is done.

1.

1 = Station 1

2.

Station OFF

4 hours

If station 3 is in the same program (with #1 and
#2) it will run after STATION 2 is done, etc.

SET the station’s duration (running time) in min-
utes.

A

A

A

1.

Press

SELECT PROGRAM

SELECT PROGRAM

.

Press

SELECT PROGRAM

SELECT PROGRAM

.

3.

Содержание E-3

Страница 1: ...Please read the in structions carefully and keep this manual in a handy location for future reference PROGRAMMING CONTROLS The following is a key to the buttons and icons on the E Class controller fa...

Страница 2: ...ll struggling with your old sprinkler timer Having a hard time complying with local watering restrictions Upgrading to a new Rain Bird sprinkler timer is easier than you might think New timers are eas...

Страница 3: ...6 will flash in the display Press or to set to the current year 3 Press ENTER ENTER to enter your selection 4 The digits for the current month will now flash 01 Press or to set to the current month 5...

Страница 4: ...s with today s number and abbreviation The seven weekdays are dis played as a row of numbers For example Mon day is 1 Tuesday is 2 etc 1 2 The square around a day s number means it is a water day To t...

Страница 5: ...ress ENTER until the start time you want to delete appears in the display 4 Move the start time to the blank screen just before midnight The E Class controller automatically arranges start times in th...

Страница 6: ...pears A B or C and then start over with STEP II VI ADJUST WATER BUDGET PERCENTAGE 1 WATER BUDGET allows you to increase or decrease watering time length for all stations on a Pro gram with just one ad...

Страница 7: ...of minutes you want Normal station running times in the Automatic Programs are not affected 2 STATION 2 4 STOP AT ANY STATION YOU WANT use or to set a running time for it Use ENTER ENTER to put the s...

Страница 8: ...the first stacked Program will blink 4 IX TO RUN THE TEST PROGRAM 1 2 3 You can manually advance through the stations of any program by setting the dial to AUTO and repeatedly pressing the ENTER ENTE...

Страница 9: ...ean method use this dial posi tion and the ENTER button XII MOISTURE SENSOR SETTING IF INSTALLED You can tell the controller to stop watering when an attached sensor reaches it s wet condition You can...

Страница 10: ...r automatically shuts off the station with the fault After 30 40 seconds while the E Class unit is checking again to confirm the fault the controller advances to the next station in the program Every...

Страница 11: ...the controller s micro processor Re establish power to the controller If the current time is not shown or your program is no longer in the memory reprogram the controller Open the lower access cover a...

Страница 12: ...controller down over the wall mounting bracket on models with a sliding door this overhead clearance also allows the door to be removed or rein stalled Note 2 For indoor units that do not have a slidi...

Страница 13: ...controller down over the mounting bracket until lower mounting hole D aligns with the hole in the back of the terminal strip compartment You may want to wait until after you have cut your wire conduit...

Страница 14: ...etely bare cop per wire from the power source to the green yellow wire from the controller In a similar manner con nect each of the two remaining power source wires to one of the controller s input wi...

Страница 15: ...VALVES NOTE The E Class residential controller is designed to work best with 18 gauge multi conductor cable that is approved for low voltage direct burial applications These cables usually have a whi...

Страница 16: ...trip Then if a prolonged power outage outlasts the controller s memory protection and the controller activates its default program when the pump and stations 5 or 6 are running station 4 s valve allow...

Страница 17: ...by one or more of the follow ing measures Reorient the receiving antenna Move the controller away from the receiver Plug the controller into a different outlet so that the controller and receiver are...

Отзывы: