background image

Conventional AC Operation

When using conventional AC power, the engine will respond to changes in track 
voltage. An increase in track voltage will increase the locomotive speed and a 

reduction in track voltage will reduce the engine speed.

A short interruption (approximately 1 to 2 seconds) in the track voltage will cause the 

engine to cycle in the sequence for each track voltage interruption (neutral – forward – 
neutral – reverse) When power is first applied to the track, the locomotive will be 

silent for 1-20 seconds and the headlight will be on, indicating the super capacitors are 

charging (The super capacitors provide power to the sound system during direction 

changes or intermittent drops in track power due to dirty track 

 switches, when 

operating in conventional mode). When the super capacitors are charged, all the lights 

will come on and the engine sounds will start up. There should be no movement, as 

the engine is in neutral. Causing a short interruption of track power by using the 

direction button on the transformer, or by bringing the throttle to 0 volts and back 

again, will change the sequence to the forward state. Then increasing the throttle will 

begin to move the engine forward, and speed will increase as the throttle is advanced.

If there is another interruption in track power the sequence will change to the neutral 

position again. The engine will remain in the neutral state until there is another 
interruption in track power. The next interruption in track power will move the 
sequence to the reverse state. The engine will now move in the reverse direction. If the 

power interruption was accomplished by using the direction button and the throttle 
position was not changed, the engine will run in the reverse direction at the same 
speed that it was traveling in the forward position.

Subsequent interruptions in track power of 1-2 seconds will continue the sequence 
rotation. If you happen to interrupt track power for longer than about 2 seconds, the 
engine will begin its shut down sounds. If this occurs you can cycle the direction 
sequence again to get back to the direction you wish to move and once the engine 
starts moving its shut down sounds will stop playing (SEE PAGE 8 (direction cycle 
phases)).

In conventional AC operation the whistle sound, the bell sound, PFA sounds and 
other operational functions can be accessed if your transformer has a horn/whistle 
button and a bell button. By using combinations of  button presses, different 
commands besides blowing the whistle and ringing the bell can be initiated.

or on

 

RailKing 

 Diesel Engine w/Proto-Sound® 3.0

7

SD60

Содержание SD60

Страница 1: ...s engine will operate on any traditional O 31 Gauge track system including M T H s RealTrax or ScaleTrax or traditional tubular track It is also compatible with most standard AC transformers See pages...

Страница 2: ...Begin 3 Set Up Checklist 3 Lubrication 3 Priming the Smoke Unit 3 PS 3 0 Enhancements 5 Conventional AC DC Start up Shut down 5 DCS DCC Switch 5 Programming Track for DCC operation 6 Loading Engine Fi...

Страница 3: ...l and follow the lubrication points marked L shown below Do not over oil Use only a drop or two on each pivot point Priming the Smoke Unit When preparing to run this engine add 15 20 drops of smoke fl...

Страница 4: ...RailKing Diesel Engine w Proto Sound 3 0 4 SD60 Running the engine without a primed smoke unit may cause damage Figure 2 Adding Smoke Fluid Figure 3 Smoke Unit Control...

Страница 5: ...engine you will notice the headlight comes on but nothing else This is perfectly normal The capacitors are charging up during this time The wait time depends upon how long it s been since you last app...

Страница 6: ...auge engine affords you the ability to load Engine firmware Loader version 2 30 or later will allow you to do this Please refer to the Loader program s instructions for more details So as MTH releases...

Страница 7: ...and speed will increase as the throttle is advanced If there is another interruption in track power the sequence will change to the neutral position again The engine will remain in the neutral state u...

Страница 8: ...ll button To turn the bell off press and release the Bell button again The bell will continue to ring from the time you turn it on until you press and release the button again to turn it off Horn Whis...

Страница 9: ...volume and counterclockwise to reduce the volume Turning the manual volume control completely counterclockwise will turn of all of the engine sounds and announcements RailKing Diesel Engine w Proto So...

Страница 10: ...in will not move as you use the Direction button to trigger the sounds Proto Sound 3 0 has disabled operator control over the Horn and Bell buttons until the full PFA sequence is complete After waitin...

Страница 11: ...econds You do not have to be in Forward to use PFA At the conclusion of the full sequence the train will pull away from the station or yard in whatever direction you were going when you activated the...

Страница 12: ...on forward neutral or reverse so that it will not change directions To do this put the engine into the direction you want or into neutral to lock it into neutral run it at a very slow crawl as slowly...

Страница 13: ...s cannot be initiated in conventional DC Only the diesel engine sounds smoke squealing brakes and idle sounds will function Operation of your MTH Proto Sound 3 0 engine in conventional DC is very simi...

Страница 14: ...the engine at start up the engine will not move This is normal We refer to this as Anti Jackrabbit and this feature prevents your model from taking off at high track voltages Simply lower the track vo...

Страница 15: ...trol station manufacturer s manual for more information on how they handle F Function buttons Your MTH PS3 0 equipped engine s default short address is 3 So all you have to do is power up your DCC sys...

Страница 16: ...inging 2 Slowly reduce the throttle until the train stops at the desired location and speed reaches zero Press the F4 button twice toggle F4 on then off again and the bell will stop ringing You will h...

Страница 17: ...Signal Pressing F10 twice toggling on then off will sound the Reverse Signal This is three whistle horn blasts Grade Crossing Signal Again just like a real engine you can trigger the Grade Crossing S...

Страница 18: ...ounds by pressing F18 twice toggling on then off The Extended Shut Down is very similar to F3 in that the engine will ultimately shut down but in the case of Extended Shut Down you will hear the crew...

Страница 19: ...realism F24 Single Whistle Horn Blast To play a Single Horn Blast press the F24 button twice toggling in on then off This plays a single short horn blast F26 Brake Sounds Pressing the F26 button enabl...

Страница 20: ...oupler Rear Coupler Forward Signal Reverse Signal Grade Crossing Smoke On Off Smoke Volume Idle Sequence 3 Idle Sequence 2 Idle Sequence 1 Extended Start Up Extended Shut Down Rev Up Rev Down One Shot...

Страница 21: ...C address The default Short address is always 3 The default Long address will be 3333 To change your engine s Short Address using PoM 1 Call up the engine s current address on your DCC handheld 2 Ente...

Страница 22: ...y Resets Clears everything takes engine to just like it was when you got it brand new l Send a decimal 08 to CV 8 to reset everything entirely back to factory default l Send a decimal 192 to reset eve...

Страница 23: ...facturer s engines with an address of 55 are on the rails MTH engines will listen for commands coming to engine address 55 when the 55 55 55 reset is enabled even though they are not programmed as add...

Страница 24: ...will tell the engine it s reversed in a consist Defines active Function F1 F8 for the active consist Defines active functions for FL and F9 F12 for the active consist bit 0 1 will tell an engine that...

Страница 25: ...2 Alternate Speed Curve Step 23 Alternate Speed Curve Step 24 Alternate Speed Curve Step 25 Alternate Speed Curve Step 26 Alternate Speed Curve Step 27 Alternate Speed Curve Step 28 Reverse Trim User...

Страница 26: ...Bell Brake Sounds Cab Chatter Clickety Clack Coupler Close Coupler Slack Drift Chuff Engine Sounds Forward Signal Grade Crossing Signal Horn Idle Sequence 1 Idle Sequence 2 Idle Sequence 3 Idle Sequen...

Страница 27: ...DCC controller The engine will give you a two horn blast indication Note You ve also left an empty location where PFA used to be F4 5 Now you can fill that location with whichever CV you d like For t...

Страница 28: ...9 set to 0 Setting the MSB Bit 7 of CV19 tells the engine that it is facing reverse in the consist Setting CV21 and CV22 determine which F Functions the consist responds to See diagram below for examp...

Страница 29: ...ne s address Most systems have a light bulb icon to indicate whether F0 is active or not Ensure that it is OFF 5 Call up the Rear engine on your DCC handheld address 3 in this example 6 Set CV19 to 12...

Страница 30: ...set which F Functions you want the consist address to control For example you will likely want all of your MTH consist engines to respond to Start Up Shut Down F3 Also you ll likely want at your Fron...

Страница 31: ...ng Track differ it is recommended that you use a DCC Programming Track Booster to perform functions on the programming track Simply put try to program or read back the address of an MTH engine on a pr...

Страница 32: ...CV29 you would simply add the additional bits you enabled to the existing value to obtain the new CV value For example if you had a consist address CV19 set to 5 and you wanted to alter this to show...

Страница 33: ...screwing the black Phillips motor mount screw located on the underside of the drive trucks fig 7 3 Once the motor mount screw has been removed pull the motor away from the truck block and lightly coat...

Страница 34: ...nd tires can be cleaned using denatured not rubbing alcohol applied with a cotton swab To clean the track use RailKing Track Cleaning Fluid found in Maintenance Kit 30 50051 or denatured not rubbing a...

Страница 35: ...find it useful to use two small flathead screwdrivers to stretch the tire over the wheel 5 If you twist the tire while stretching it over the wheel you will need to remove and reinstall the tire Other...

Страница 36: ...turn off the smoke unit control Fig 3 by turning to full Counter Clockwise Position Failure either to add fluid to the unit or to turn it off may damage the smoke unit heating element and or wicking...

Страница 37: ...enerate a lot less heat than incandescent bulbs resulting in extremely long life compared to the incandescent bulbs The LEDs are not user serviceable If you experience poor or no smoke output when the...

Страница 38: ...t be sending enough power to the track to power the engine Rotate throttle clockwise to increase track power Coupler Solution When I try to fire the coupler PFA starts The Proto Coupler won t let the...

Страница 39: ...ine doesn t go into reverse When the PFA enters its last sequence the bell automatically comes on When PFA is enabled pressing the whistle and bell has no effect I push the direction button but the ne...

Страница 40: ...ll CW Max volume Check to see if a screw or some other material hasn t lodged itself in the underside of the chassis or tender Make sure smoke volume pot is turned full CW Make sure smoke volume pot i...

Страница 41: ...power to the track my engine starts up lights and sound but it won t move My engine hesitates at slow speeds Lower the track voltage then raise it again The engine should start moving If you apply gr...

Страница 42: ...the F21 button again to turn Doppler off Your engine sounds will now return to normal Check to see if a screw or some other material hasn t lodged itself in the underside of the engine Smoke Solution...

Страница 43: ...ing This is normal dial up the speed on your DCC controller to make your engine move PFA Solution Shut Down Solution Okay I give up What do I have to do to shut it down Well you can either remove powe...

Страница 44: ...turn Doppler off Your engine sounds will now return to normal When I apply power to the track my engine doesn t do anything No lights no sound no nothing I get an error when I hit Start Up DCS is pol...

Страница 45: ...itself after the PFA is over Press the DIR button Your engine will stop and begins the arrival sequence Pressing the DIR button will cycle you through the next 3 PFA sequences This is normal The engin...

Страница 46: ...tt Standard Lionel 1063 Lionel LW Powermaster U A U A U A 8 17v 8 18v 8 18v 60 Watt 75 Watt 135VA Standard Standard Electronic All Trol Left Terminal Right Terminal 0 24v 300 Watt Electronic Dallee Ho...

Страница 47: ...VDC on Supply 0 18VDC at Controller 240 Watt Electronic MRC 6200 0 18 5v 60 Watt Electronic Not Recommended For 70 3001 1 J3a Not recommended for 70 3001 1 J3a RECOMMENDED DC TRANSFORMERS Notes On Use...

Страница 48: ...o Sound 3 0 engines but does not turn off the input power to the TIU One Touch Global Mute UnMute Single button mutes or unmutes all DCS controlled locomotives sounds Proto Dispatch Operation Public A...

Страница 49: ...vice Centers If you need assistance at any time email MTH Service at service mth railking com or call 410 381 2580 Limited One Year Warranty All M T H products purchased from an M T H Authorized Retai...

Отзывы: