background image

Set Up

Connect the red wire to the AC hot on your transformer, and the black wire to the ground on the transformer.
Operate between 12 and 18v.

Wiring Instructions

Smoke Unit
Remove cap from roof marked “S” and a

dd 15-20 drops of smoke fluid through the smokestack before running.  

We recommend M.T.H. ProtoSmoke, Seuthe or LGB fluids.  Do not overfill the unit or the fluid may leak out and coat the 
interior components. Failure to add fluid to the unit may damage the smoke unit heating element and/or wicking material.
THIS ACCESSORY CANNOT RUN WITHOUT FLUID IN THE SMOKE UNIT.

Remove cap from roof marked “W” and pour 1/4 cup water into water fill area (clear plastic pool). Do not over fill. 
(The factory can function without water - the pump will not burn up). 
To drain water, pull the rubber drain plug located on bottom of factory.
(Please note that the figure must be elevated above the water pool. If not, gravity will force water through the hose). 

Adding Water

Smoke Unit

Drain Plug

Water Fill Area

Water Fill Smoke Fill

AC

ACG

Содержание Operating Factory on Fire

Страница 1: ...re glow from inside gives off the impression that the factoryis ablaze Fortunately the fireman outsideis on alert and is diligently washing down the factory with his hose asreal water streams out and water is going in the window The water is self contained inside the structure and recirculates through the fireman s hose Everything comes painted and assembled Installation is easy and quick ELECTRIC...

Страница 2: ...rs and persons supervising use examine the unit periodically for conditions that may result in the risk of fire electric shock or injury to persons such as damage to the primary cord plug blades housing output jacks or other parts In the event such conditions exist the unit should not be used until properly repaired This unit is intended for indoor use only Do not operate with damaged wires or cli...

Страница 3: ...Components Fireman on Base Ladder Fireman that goes on Ladder w Hose Nozzel Smoke Fluid Pipette Cleaning Pin Hose Cap ...

Страница 4: ...onents Failure to add fluid to the unit may damage the smoke unit heating element and or wicking material THIS ACCESSORY CANNOT RUN WITHOUT FLUID IN THE SMOKE UNIT Remove cap from roof marked W and pour 1 4 cup water into water fill area clear plastic pool Do not over fill The factory can function without water the pump will not burn up To drain water pull the rubber drain plug located on bottom o...

Страница 5: ...htly once operation starts because the water pressure will vary with different transformers and voltages You will need to use the hose cap to prevent water from leaking when not in use WARNING This product shoots out water If you wet any electrical components on your layout you could cause short circuiting and serious injury could result You must take the appropriate steps to waterproof the areas ...

Страница 6: ... to ladder If you do not wish to use glue you can clamp the figure s feet down w the ladder see Figure 1 Position figure to shoot water inside the window without a window sheet see Figure 2 You will need to secure the ladder to your layout so the force of the water does not knock it over The window without a window sheet Figure 3 ...

Страница 7: ...emove 4 screws holding water fill and motor 3 Remove two light housing mounting screws 4 Remove red rotating light housing 5 Pull out light bulbs 6 Reassemble in reverse order Light Housing Mounting Screws Light Bulbs Light Housing Remove 6 Screws ...

Страница 8: ...ter a few hours of use because the smoke fluid will settle into the water The sediments can clog the nozzle that the fire fighter is holding To clean the nozzle you must take off the hose connected to the nozzle and push the pin through the nozzle starting at the small end To help prevent the hose from clogging up change the water in the reservoir before each use Small End of nozzle where you inse...

Страница 9: ..._______________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ____________...

Страница 10: ...dless of whether you discussed the problem with a service technician when contacting the Service Center for your Return Authorization Please make sure you have followed the instructions carefully before returning any merchandise for service Authorized M T H Service Centers are independently owned and operated and are not agents or representatives of M T H Electric Trains M T H assumes no responsib...