GR5630-SB3+ User Manual
3
LED Indicators :
2. Operating Information
3. Hardware Requirements and Precautions
Operating Temperature : 10 ~ 35 °C (50 ~ 95 °F)
Storage Temperature : -20 ~ 47 °C (-4 ~ 116 °F)
Relative humidity : 5% to 95% noncondensing
Line Voltage : 100~240V AC
1. Only one interface connection may be used at once per computer system.
2. RAID volume formation utilizes the capacity of whichever hard drive has the smallest and then
multiply that capacity by three for RAID 5, four for RAID 0, to form a large volume, therefore,
it is recommended to only install hard drives of the same brand and specification for all drive
position prior to use. Moreover, when you need to replace with a new hard drive, please be sure
to purchase one with the same specification, capacity and brand. If these conditions can’t be met,
select one that’s at least 20 GB greater in capacity.
3.
The actual storage capacity of GR5630-SB3+ recognized by the system may differ from the total
capacity stated on the hard drives once the drives have been formatted.
4.
When connected to the computer system, it’s prohibited to remove, insert or swap the hard drive
while data transfer is being performed.
5.
It’s prohibited to change the positioning of the drives once the initial installation has been
completed as the changes made to the drive positions may destroy the RAID formation.
6. If you discover that hard drive failure is taking place, go to Section 6 “Replacement of
Malfunctioning Drive and Data Rebuild Instructions” and follow the steps accordingly.
Constant
Front LED
Buzzer
Power LED
Larm LED
HDD LED
Power ON
Blue
— —
Blue Flashing → Blue
1 long when
booting finished
No HDD
Blue
— —
— —
— —
Disk Failed
Blue
— —
Red
— —
RAID Failed
Blue
— —
Red
4 Short
Disk Idle
Blue
— —
Blue
— —
Format
Blue
— —
Blue Flashing
— —
Access
Blue
— —
Blue Flashing
— —
Rebuilding - Source
Blue
— —
Blue Flashing
— —
Rebuilding - Target
Blue
— —
Blue and Purple Flashing
— —
Fan Failed
Blue
Red
Blue
4 Short
Over Temp
Blue
Red
Blue
4 Short