RafterEye RE1 Скачать руководство пользователя страница 4

 

Situations requiring center correction 

1. Sistered rafters

 

Where two rafters are sistered (fastened together side-to-side), the RE1 will 
cause the compass to locate the center location between the two rafters. Since 
this position is a void, it is NOT desirable as an attachment point. Therefore, the 
person marking on the roof must be instructed to locate the center of the pre-
ferred rafter.  In the case of two sistered rafters, each measuring 1-1/2” thick, 
the center of either rafter would be ¾” away from the midpoint indicated.  For 
three sistered rafters, if the center position is void or not preferred for attach-
ment, the location would be displaced by 1-1/2” to an outer member. 

2. Slanted rafters 

When locating a rafter that is warped and off-plumb by no more than 10° at the 
target location, rotate the magnet blocks to the slots-up position (Fig. 3). Clamp 
them to the rafter as usual. Due to the rafter’s tilt, only one corner of each 
magnet block should touch the bottom of the roof deck.  The “center” position 
identified by the Compass block on the roof deck will be suitable for a fastener 
to enter perpendicular to the roof surface and remain in the center portion of 
the top 2.5” of the rafter.  If the fastener will enter significantly deeper into the 
rafter, further displacement to compensate for the skew may be necessary. 

3. Distorting fasteners

 

An off-center ferrous metal fastener in the deck and/or rafter directly within 
the magnetic field may distort the field enough to give a slightly inaccurate 
reading. (It will indicate a location deviated from center toward the fastener.) If 
fastener locations are visible (from above the deck or below), avoid them. Usu-
ally the effect is negligible, but if necessary, either of two methods may be used 
to correct fastener-caused distortion. 

METHOD 1. LIFT COMPASS:

 Start with 

compass against roof and North-pointing needle end pointing straight down 
perpendicular to roof surface. Gradually lift compass straight upward 1-2” 
above the roof surface. If the needle moves left or right as the compass is 
raised, relocate compass in mid-air until needle points straight down. This will 
be closer to rafter center than the position indicated when the compass was on 
the roof surface. 

METHOD 2. RELOCATE MAGNET BLOCKS. 

After marking a 

center reading, move magnet blocks a few inches away along the length of the 
rafter.  If readings differ significantly, use a third nearby location or Method 1 
to determine which reading is distorted. 
 

  

 

Limited Warranty of RafterEye RE1 

RafterEye LLC warrants the RE1 Rafter Center Locator against defects in  
material and manufacture for one year from the date of purchase. Seller’s sole 
obligation and your exclusive remedy under this Limited Warranty and, to the 
extent permitted by law, any warranty or condition implied by law, shall be the 
repair or replacement of parts, without charge, which are defective in material 
or manufacture and which have not been misused, carelessly handled, or mis-
repaired by persons other than the Seller. To make a claim under this Limited 
Warranty, you must return the complete tool, transportation prepaid, to: 

RafterEye LLC  
Customer Service 
511 N Cuesta Ave 
Tucson AZ 85745 

IN NO EVENT SHALL SELLER BE LIABLE FOR ANY INCIDENTAL OR CONSEQUEN-
TIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LIABILITY FOR LOSS OF 
PROFITS) ARISING FROM THE SALE OF THIS PRODUCT. This warranty may pro-
vide you with additional rights that vary by state, province or nation. 

The Limited Warranty does not apply to depolarization of the Compass.  Cor-
rection of this condition is explained in the User’s Guide and at RafterEye.com.  

This Limited Warranty applies only to tools sold within the United States of 
America, Canada and the Commonwealth of Puerto Rico. 

RafterEye LLC     RafterEye.com 

511 N. Cuesta Ave, Tucson AZ 85745     [email protected]     520-261-2656

 

 