Radyne XICOM 310-0415-002 Скачать руководство пользователя страница 6

Operation

MNC-0400-012

6 of 8

Revision D

Initial Turn On

The Initial Turn On procedure has three parts:

Prepower Check.

Turn On.

Turn Off.

This procedure should be followed to ensure proper operation of 
the amplifier and to avoid permanent damage to the amplifier.

Caution

Ensure that all of the following instructions are followed. Failure 
to comply could result in permanent damage to the amplifier.

Vorsicht 

Stellen Sie sicher, dass alle folgenden Anweisungen befolgt 
werden. 

Nichtbeachtung kann bleibende Schäden am Verstärker 
verursachen.

Prepower Check

1. The prime power voltage is within the specified limits of the 

amplifier.  The correct power input connector pins must be used, 
dependent on voltage level and the prime power source.  Refer to 
the appendix titled 

Mechanical Drawings

  for connector pin outs.

2. The amplifier is installed within an enclosure.  The exhaust air from 

the amplifier should be ducted to the outside of the cabinet so that 
the warm air is not recirculated into the amplifier's air intake.

3. The RF output is terminated with a load capable of dissipating the 

power of your unit.  This load should have a maximum VSWR of 
1.5:1. The RF drive signal is within the frequency range of the 
amplifier's specification. Refer to the appendix titled 

Specifications

 

for rated power gain.

Caution

Do not exceed the RF input power limit as defined in the 
product specification. Doing so will cause the SSPA to 
overheat.  Failure to comply could result in permanent damage 
to  the SSPA.

Содержание XICOM 310-0415-002

Страница 1: ...itiated By 1 Preliminary Release 04 02 2002 A L Crozier Jr A 9869 Original Release 06 05 2002 A L Crozier Jr B 10033 Update to reflect amplifier improvement 08 05 2002 A L Crozier Jr C 12707 Add Germa...

Страница 2: ...lt Mode 3 Summary Fault 3 Power Supply Voltage Fault 4 SSPA Overtemperature Fault 4 Reverse Power Fault 4 Clearing Faults 4 Control and Status Signals 5 Control Signals 5 AC Power ON 5 Normal M C Inte...

Страница 3: ...es amplifiers Control and status signals are accessed via a 32 pin interface connector or an IrDA Interface Operating Modes There are three amplifier operating modes Standby Transmit ON Fault Standby...

Страница 4: ...erature of the base plate is reduced to a safe operating level Power supply voltage will automatically be enabled when the over temperature fault clears Note An over temperature fault should be cause...

Страница 5: ...source ON OFF control of the AC input is at the prime AC power source The system can be controlled through the following pins on the interface connector J1 Reset computer connect Pin h to Pin f 15 Vdc...

Страница 6: ...r input connector pins must be used dependent on voltage level and the prime power source Refer to the appendix titled Mechanical Drawings for connector pin outs 2 The amplifier is installed within an...

Страница 7: ...s applied The control system is held in the reset mode until the J1 Pin h is connected to either J1 Pin Z or J1 Pin a This allows the control system to operate normally Note In manual operation the sy...

Страница 8: ...in the same state as it was when you turned it off Generation 2 Power Supply The SSPA is switched off by turning OFF the prime AC power using the circuit breaker If you turn the system OFF it will tu...

Отзывы: