User Interfaces
SFC4200/SFC1275G Synthesized Frequency Downconverter
4-14
TM054 - Rev. 4.0
4.2.6 Switch Configuration Menu
This Menu (refer to Figure 4-12) is applicable for a 1:8 Backup Converter. It allows the operator
to specify the priority of the various converters. The priority is as follows: 1 (Highest Priority)
through 8 (Lowest Priority), and 0 (No Priority, the Backup will ignore the Prime).
Figure 4-12. Switch Configuration Menu
The Arrow Keys are used to move left and right, and increase or decrease a converter’s priority.
When all of the priorities have been set, pressing the <ENTER> causes the Backup to accept the
entries and store them in Non-Volatile RAM. Pressing <MENU> will scroll to the next menu.
4.2.7 Learn Menu (Backup Converter Only)
Depressing <MENU> will scroll to the Configuration Menu. Depressing <ENTER> will cause the
Backup Converter to ‘Learn’ about the Primary Converter (Figure 4-13).
Figure 4-13. Learn Menu
The screen automatically scrolls to the Learn Status Menu
4.2.8 Learn Status Menus (Backup Converter Only)
The Automatic Learning in Progress Window (Figure 4-14) indicates that the Backup Converter
is polling the Prime Converter in order to learn about it.
Figure 4-14. Automatic Learning in Progress Window