User Interfaces
DMD2401 LB/ST L-Band Satellite Modem and ODU Driver
4-28
TM075 – Rev. 1.3
1.Main Menu IF Input (dBm :-38 SW:F04780-- Ver:1.3
2.Control Mode:Ft Panel Eb/No :>20.00 Intf Pres :G.703 T1/E1 S
3.Remote Mode :RS-485 Uncorrected SER:0 E-5 +5 V Mon :+4.9
4.Remote Addr :101 Corrected BER:0 E-12 +12 V Mon :+12.5
Offset Frq (Hz:+0 -12 V Mon :-11.9
6.Center Buffer 2047 Error Cnt :NO SYNC Events :20
Buffer Fill%:50 2047 BER :NO SYNC
---------------------G.703 SYMMETRIC INTERFACE CONTROLS-------------------------
GENERAL TX SETUP RX SETUP
31.EXC Clock :2048000 51.Tx G703 Intf:G703BT1AMI 71.Buffer/byte :6176
32.Ref Source:Internal 72.Buffer/msec :32
33.Ext Ref Fq:10.000000 73.Buff Clk Sel:RX SAT
74.Rx G703 Intf:G703BT1AMI
42.Tx Ckt ID :
43.Rx Ckt ID :
Enter Selection Number:
Figure 4-12. G.703 Symmetric Control Terminal Screen
4.4 Remote Port User Interface
The Remote Port of the DMD2401 LB/ST allows for complete control and monitor functions via
an RS-485 or RS-232 Front Panel Selectable Serial Interface.
Control and status messages are conveyed between the DMD2401 LB/ST and the subsidiary
modems and the host computer using packetized message blocks in accordance with a
proprietary communications specification. This communication is handled by the Radyne Link
Level Protocol (RLLP), which serves as a protocol ‘wrapper’ for the M&C data.
Complete information on monitor and control software is contained in the following sections.
4.4.1 Protocol Structure
The Communications Specification (COMMSPEC) defines the interaction of computer resident
Monitor and Control software used in satellite earth station equipment such as Modems,
Redundancy Switches, Multiplexers, and other ancillary support gear. Communication is bi-
directional, and is normally established on one or more full-duplex 9600-baud multi-drop control
buses that conform to EIA Standard RS-485. If a single device is placed on a single control bus,
then the control bus may conform to EIA Standard RS-232.
Each piece of earth station equipment on a control bus has a unique physical address, which is
assigned during station setup/configuration or prior to shipment. Valid decimal addresses on one
control bus range from 032 to 255 for a total of up to 224 devices per bus. Address 255 of each
control bus is usually reserved for the M&C computer.
The Communications Specification (COMMSPEC) defines the interaction of computer resident
Monitor and Control software used in satellite earth station equipment such as modems,
redundancy switches, multiplexers, and other ancillary support gear. Communication is bi-
directional, and is normally established on one or more full-duplex 9600-baud multi-drop control
buses that conform to EIA Standard RS-485.
Each piece of earth station equipment on a control bus has a unique physical address, which is
assigned during station setup/configuration or prior to shipment. Valid decimal addresses on one
control bus range from 032 through 255 for a total of up to 224 devices per bus. Address 255 of
each control bus is usually reserved for the M&C computer.