![Radyne ComStream DM240-DVB Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/radyne-comstream/dm240-dvb/dm240-dvb_installation-and-operation-manual_3362208097.webp)
DM240-DVB High-Speed Digital Modulator
Appendix B
TM083 – Rev. 3.0
B-
7
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = FIFO overflow/underflow error
Bit 5 = Loss of frame synchronization
"
::= { radSNMP_Mod_NV_Status 26 }
radCommonAlarmMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Common Alarm mask:
A bit field. 0 = MASKED, 1 = UNMASKED
Bit 0 = -12V alarm.
Bit 1 = +12V alarm.
Bit 2 = +5V alarm.
"
::= { radSNMP_Mod_NV_Status 27 }
radOperatingMode OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
test_pattern_2_15(1),
test_pattern_2_23(23)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Test Pattern Operating Mode:
None,
(2^15)-1,
(2^23)-1
"
::= { radSNMP_Mod_NV_Status 28 }
radCarrierTest OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
cw(1),
dual(2),
offset(3),
posfir(4),
negfir(5)
}
ACCESS read-write
STATUS current
DESCRIPTION
"normal, allows normal modulated data output
cw, causes the modulator to output pure carrier
dual, causes a double sideband output
offset, causes a single side band output
posfir, uses a positive FIR
negfir, uses a negative FIR"
::= { radSNMP_Mod_NV_Status 29 }
radCircuitID OBJECT-TYPE
SYNTAX RadString (SIZE (11))
ACCESS read-write
STATUS optional
DESCRIPTION
"Provides entry of Tx circuit identifier. Circuits can
be given up to 11 character alphanumeric identity such
as LINK1. Not implemented."
::= { radSNMP_Mod_NV_Status 30 }
radControlMode OBJECT-TYPE
SYNTAX INTEGER {
local(0),
terminal(1),
Содержание DM240-DVB
Страница 3: ......
Страница 13: ...Introduction DM240 DVB High Speed Digital Modulator 1 2 TM083 Rev 3 0...
Страница 17: ...Installation DM240 DVB High Speed Digital Modulator 2 4 TM083 Rev 3 0...
Страница 23: ...User Interfaces DM240 DVB High Speed Digital Modulator 4 4 TM083 Rev 3 0 Figure 4 2 DM240 Main Programming Menu...
Страница 49: ...User Interfaces DM240 DVB High Speed Digital Modulator 4 30 TM083 Rev 3 0 Figure 4 12 RF Switch Control Menu...
Страница 63: ...Maintenance and Troubleshooting DM240 DVB High Speed Digital Modulator 6 2 TM083 Rev 3 0...
Страница 67: ...Technical Specifications DM240 DVB High Speed Digital Modulator 7 4 TM083 Rev 3 0...