RADWIN
5000
Configuration
Guide
Release
4.9.17
4
‐
33
Ethernet
Managing
the
Sector
Figure
4
‐
18:
HBS
Collocated
master
Moving
the
slider
to
the
right
yields
the
following:
The
effective
available
range
for
Asymmetric
allocation
is
determined
by
channel
bandwidth
as
shown
as
well
as
link
distance.
In
this
context,
“link”
is
any
collocated
RADWIN
HBS,
not
necessarily
a
RADWIN
5000
HBS.
QoS
Configuration
To
use
the
Ethernet
QoS
feature,
see
(includes
VoIP
configuration).
Advanced
Broadcast/Multicast
Flooding
Protection
:
Broadcast/Multicast
Flooding
Protection
provides
a
measure
of
protection
by
limiting
multicast
and
broadcast
packets
to
no
more
than
12.5%
of
available
capacity.
You
may
wish
to
un
‐
check
this
item
if
your
application
is
based
on
multicast/
broadcast
packets
‐
for
example,
video
surveillance
using
multicast
downlink,
or
video
conferencing
using
multicast
uplink.
The
allowable
range
is
from
50/50
%
to
75/25
%.
Setting
values
beyond
this
range
will
cause
unpredictable
results.
You
must
ensure
that
the
range
remains
within
allowable
values.
There
is
no
fail
‐
safe.