RADWIN
5000
HPMP
User
Manual
Release
3.5.70
24
‐
2
Two
Ways
to
Run
Spectrum
View
Two
Ways
to
Run
Spectrum
View
Spectrum
View
may
be
run
from
the
HBS
in
which
case
you
have
a
choice
of
analyzing
all
sites
in
the
sector
in
one
run,
or
making
a
selection.
Spectrum
View
may
also
be
run
on
a
managing
computer
directly
connected
to
an
HSU.
Remember
that
in
such
a
case
the
results
will
be
quite
different
if
the
HSU
is
part
of
a
sector
(registered
or
not)
or
if
it
is
completely
stand
‐
alone,
for
example
using
a
different
spectral
range
and
operating
Band
from
the
HBS.
In
the
former
case,
expect
a
“noise
hump”
around
the
channels
used
by
the
sector,
due
to
the
duty
signals
from
the
HBS.
Where
is
the
Spectrum
View
Data
stored
Spectrum
View
data
is
always
stored
in
the
ODU
originating
the
analysis.
The
HBS
maintains
the
last
Spectrum
View
analysis
data
for
all
members
of
the
sector.
If
you
run
Spectrum
View
from
a
directly
connected
HSU,
it
stores
its
own
data,
which
may
be
quite
different
from
the
analysis
obtained
for
the
same
HSU
from
the
HBS.
Spectrum
View
Main
Window:
HBS
In
this
section
we
review
the
main
window
management
controls.
Click
the
Spectrum
View
button
.
The
Spectrum
View
main
window
opens
in
full
screen
mode:
Содержание 5000 HPMP
Страница 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Страница 21: ...Part 1 Basic Installation Release 3 5 70...
Страница 69: ...Part 2 Sector Installation Release 3 5 70...
Страница 155: ...Part 3 Sector Management Release 3 5 70...
Страница 191: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 36 Inventory Inventory You should note the details for each HSU...
Страница 193: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 38 Date Time Date Time The functionality is identical as that for the HBS...
Страница 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Страница 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Страница 290: ...Part 4 Site Synchronization Release 3 5 70...
Страница 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Страница 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Страница 354: ...Part 6 Field Installation Topics Release 3 5 70...
Страница 387: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 12 Configure If you change any of these fields you will cause a HBS reset...
Страница 395: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 20 WEB Interface for VMUs The current position is marked with the icon...
Страница 396: ...Part 7 Product Reference Release 3 5 70...
Страница 510: ...RADWIN 5000 HPMP User Manual Release 3 5 70 F 5 Montage sur un mur Montage sur un mur Figure F 5 Montage sur un mur...
Страница 517: ......