Radware Alteon Installation and Maintenance Guide
Initial Configuration
Document ID: RDWR-ALOS-V2815_IG0203
45
To connect to a device through Telnet, use a computer running Telnet software. Before a Telnet
session can be established, the device must have an IP address. The device can only be assigned an
IP address manually during the device configuration process.
Note:
To use the management port, the port must be manually configured with a unique IP
address and Telnet access must be enabled (
/cfg/sys/access/tnet ena
).
Establishing an SSH Connection
Although a remote network administrator can manage the configuration of an Alteon device through
Telnet, this method does not provide a secure connection. The SSH (Secure Shell) protocol enables
secure remote login and communication not provided by Telnet. As a secure alternative to using
Telnet to manage device configuration, SSH ensures that all data sent over the network is encrypted
and secure.
For more information on how to establish an SSH connection, see the Alteon Application Switch
Operating System Command Reference.
Initial Device Connection
When a connection has been established with the device, the initial screen is displayed.
Initial Screen for Alteon Application Switch 4408
The following is example text of the initial screen for Alteon Application Switch 4408.
System Information at 11:39:49 Mon Feb 1, 2010
Time zone: No timezone configured (GMT offset -8:00)
Memory profile is Default
Alteon Application Switch 4408
Switch is up 0 days, 0 hours, 0 minutes and 17 seconds.
Last boot: 11:39:32 Mon Feb 1, 2010 (reset from console)
Last apply: 11:21:07 Mon Feb 1, 2010
Last save: 11:35:29 Mon Feb 1, 2010
MAC Address
: 00:03:b2:50:5b:c0
IP (If 1) Address
: 10.210.11.145
Hardware MainBoard No|Rev : NSA5110-E2SFP | A.01
Hardware DB No
: Not Available
Hardware Serial Number
: 21903260
Note - When the measured temperature inside the switch EXCEEDs
the anomaly threshold at 54 degree Celsius or the critical
temperature at 73 degree Celsius different syslog messages
will be generated.
Software Version
28.1.5.0 (FLASH image1), active configuration.
Содержание Alteon
Страница 2: ...Radware Alteon Installation and Maintenance Guide 2 Document ID RDWR ALOS V2815_IG0203...
Страница 24: ...Radware Alteon Installation and Maintenance Guide Table of Contents 24 Document ID RDWR ALOS V2815_IG0203...
Страница 40: ...Radware Alteon Installation and Maintenance Guide Installing the Platform 40 Document ID RDWR ALOS V2815_IG0203...
Страница 62: ...Radware Alteon Installation and Maintenance Guide Initial Configuration 62 Document ID RDWR ALOS V2815_IG0203...
Страница 74: ...Radware Alteon Installation and Maintenance Guide Troubleshooting 74 Document ID RDWR ALOS V2815_IG0203...
Страница 92: ...Radware Alteon Installation and Maintenance Guide Specifications 92 Document ID RDWR ALOS V2815_IG0203...
Страница 98: ...Radware Alteon Installation and Maintenance Guide 98 Document ID RDWR ALOS V2815_IG0203...