background image

 

12.1.  Inserting and cancellation of unit price 
 
The user can directly enter a unit price. 
 
Procedure: 

 

  Enter the required price using digital keys 

 to 

 

  The entered price will be displayed in the middle display window  

<UNIT PRICE   €/kg>

 

  After loading the pan the scale software will automatically indicate  

the charge in <€> in display window  <TOTAL PRICE   €> calculated  
on the basis of the entered value, 

  To cancel unit price press key 

  After inserting price wait about 5s, now it is possible to insert new price 

without cancellation of previous on with key 

 
 
 

12.2.  Saving unit price 
 
Software enables to save 99 unit prices in scale memory. 
 
Procedure: 

  While in weighing mode keep pressed 

  

and press 

 

  In display window <TOTAL PRICE   €> message <Id  1> appears  

(first position of unit price in the scale memory) but in window  
<UNIT PRICE   €/kg> the current price attributed to the position  
above is displayed , 

  In order to change the price press  

 and then using keys  

 to 

 enter a new price, 

  Enter the inscribed price to the scale memory and press 

,  

then Id in window <TOTAL PRICE   €> will be increased by 1

  Saving procedure of remaining unit prices to scale memory is  

analogous to procedure described above. 

 

  After overpassing the product number 99 the Id in window 

<TOTAL PRICE   €> will be changed to 1

 

- 11 -

Содержание WTC 6

Страница 1: ...5 S WTC 30 S WTC 6 SW WTC 15 SW WTC 30 SW M A N U F A C T U R E R O F E L E C T R O N I C WEIGHING INSTRUMENTS RADWAG Wagi Elektroniczne 26 600 Radom Bracka 28 Street POLAND Phone 48 48 384 88 00 phon...

Страница 2: ...UNCTIONS 9 11 WEIGHING 9 11 1 Scale tarring 10 11 2 Scale zeroing 10 12 FUNCTIONS OF COMPUTING SCALES 10 12 1 Inserting and cancellation of unit price 11 12 2 Saving unit price 11 12 3 Recalling of sa...

Страница 3: ...ead carefully this user manual before and use the device according to its intended use B Device should be operated in dust and vibration free environment C Weighed loads should be placed in possibly c...

Страница 4: ...s D Warranty does not cover Mechanical failures caused by inappropriate maintenance of the device or failures of thermal or chemical origin or caused by atmospheric discharge or other random event Ina...

Страница 5: ...nsions of scales of WTC SW series 5 SCALES ASSEMBLY Remove the scale from the factory package and place the scale on a flat and hard surface far from heat sources and then Pull out the transport prote...

Страница 6: ...tion wire tape 2 Before starting weighing remove tear off the foil protecting the scale pan 6 STARTING AND OPERATION After assembly see point 5 of the manual place the scale on a flat and hard surface...

Страница 7: ...h A C adapter socket and switch situated in the lower right part of the casing The socket is used only for connecting of an external A C adapter provided with the scale The scale is equipped with accu...

Страница 8: ...battery Connect the A C power adapter delivered with the scale Press placed in lower right part of casing to power up the scale 8 SCALE KEYBOARD 9 SCALE DISPLAY Display of scale series WTC S Display o...

Страница 9: ...backlight a Check corresponding unit price of the product number b Store and recall the unit price c Enter or exit unit price storing state d Shift the division valued cooperating with 8 in the calib...

Страница 10: ...e tare buffer press again Symbol over NET will be off and the indication zeroed 11 2 Scale zeroing In order to zero mass indication press key In display window WEIGHT kg symbols will be indicated abov...

Страница 11: ...s on with key 12 2 Saving unit price Software enables to save 99 unit prices in scale memory Procedure While in weighing mode keep pressed and press In display window TOTAL PRICE message Id 1 appears...

Страница 12: ...E kg message is displayed Using numerical keys to enter the required product Id to which the unit price is attributed After the change is confirmed by pressing the scale automatically returns to weigh...

Страница 13: ...utomatically switches of the backlight 13 2 Overload warning Overload is signalled over the maximum weighing range increased by 9 reading divisions In case a load is equal or greater than the defined...

Страница 14: ...status byte C weight display 6 digits Tare 6 digits Unit price display 6 digits To pay value display 6 digits 0Dh Status byte A Unit and work mode always 2Dh in retail scales Status byte B Scale stat...

Страница 15: ...ce X X X X X Check the scale contact authorized service 16 TECHNICAL PARAMETERS WTC 6 S WTC 15 S WTC 30 S Scale type WTC 6 SW WTC 15 SW WTC 30 SW Max capacity 6 kg 15 kg 30 kg Readability 2 g 5 g 10 g...

Страница 16: ...L E C T R O N I C W E I G H I N G I N S T R U M E N T S RADWAG WAGI ELEKTRONICZNE 26 600 Radom Bracka 28 Street POLAND Tel 48 48 38 48 800 tel fax 48 48 385 00 10 Selling departament 48 48 366 80 06...

Отзывы: