RADWAG MYA 4Y Скачать руководство пользователя страница 21

11.3. Weighing chamber elements disassembly

1

2

3

5

4

6

Prior disassembling weighing chamber elements make sure the microbalance is turned off and 
unplugged from the mains. When disassembling the elements, use tweezers that come standard 
with the instrument.

Open the weighing chamber by 
twisting the handle.

Lift the lid of microbalance 
weighing chamber.

Unscrew the draft shield’s sleeve counterclockwise and remove it from the 
weighing chamber.

Use your finger to press the base of the ring assembly in order to tilt the top 
edge. Grab the top edge and remove the ring assembly through the upper hole 
of the weighing chamber.

Using the tweezers, carefully remove 
the weighing pan from the weighing 
chamber.

Install and tighten the protective 
ring using the handle.

Remove the draft shield from the 
weighing chamber.

7

Содержание MYA 4Y

Страница 1: ...icrobalances UYA 4Y PLUS UYA 4Y UYA 4Y F A PLUS UYA 4Y F A Microbalances MYA 4Y PLUS MYA 4Y MYA 4Y P PLUS MYA 4Y P MYA 4Y F A PLUS MYA 4Y F1 PLUS MYA 4Y F A MYA 4Y F1 Ultra microbalances and Microbalances IMMB 01 02 11 21 EN ...

Страница 2: ... models MYA 4Y PLUS Ultra microbalance 1 Terminal 1 Weighing pan 1 Weighing pan shield 1 Glass weighing chamber lid 1 Microbalance 1 Terminal 1 Weighing pan 1 Weighing pan shield 1 Glass weighing chamber lid 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Anti draft shield 1 Tweezers 1 Brush 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 ...

Страница 3: ...ghing chamber lid 1 For models MYA 4Y P PLUS Microbalance 1 Terminal 1 Weighing pan 1 Weighing pan shield 1 Glass vessel 1 Evaporation ring 1 Glass lid with opening 1 Anti draft shield 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 Glass weighing chamber lid 1 Power supply 1 Additional glass lid 1 RS232 cabl...

Страница 4: ...ssel 1 Evaporation ring 1 Glass weighing chamber lid 1 Power supply 1 Additional glass lid 1 Fabric dust cover 1 RS232 cable 1 Glass lid with opening 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Terminal 1 Filter weighing pan 1 Weighing pan 1 Anti draft shield 1 Centring ring 1 Tweezers 1 Glass lid 1 Brush 1 Tweezers 1 Ultra microbalance 1 Brush 1 ...

Страница 5: ...RS232 cable 1 Fabric dust cover 1 Weighing pan 1 Centring ring 1 Power supply 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 Anti draft shield 1 Tweezers 1 Glass lid 1 Brush 1 Tweezers 1 Terminal 1 Brush 1 Filter weighing pan 1 Microbalance 1 Weighing pan 1 Centring ring 1 Glass lid 1 Terminal 1 Filter weighing pan 1 Weighing pan 1 Centring ring 1 Glass lid 1 Ultra microbalance 1 Microbala...

Страница 6: ...er weighing pan 1 Weighing pan 1 Centring ring 1 Microbalance 1 Terminal 1 Power supply 1 Filter weighing pan 1 Weighing pan 1 Centring ring 1 Microbalance 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 RS232 cable 1 Fabric dust cover 1 Tweezers 1 Brush 1 The plug type may vary by country ...

Страница 7: ...r to enable the most stable and repeatable measurement Avoid air drafts and air movements at the workstation Do not place the balance in a hazardous area Do not weigh explosive or flammable materials Place the balance away from heat sources Avoid exposing the balance to the sunlight Make sure that the balance is placed on an even surface Avoid exposing the balance to a mag netic field Do not weigh...

Страница 8: ...ON 4 1 Transport lock removal Prior to balance assembly remove the transport lock 5 1 Weighing chamber components assembly 1 1 2 2 3 3 4 5 COMPONENTS ASSEMBLY For models UYA 4Y PLUS MYA 4Y PLUS UYA 4Y MYA 4Y For models MYA 4Y P PLUS MYA 4Y P ...

Страница 9: ...5 6 1 2 3 For models UYA 4Y F PLUS MYA 4Y F PLUS UYA 4Y F MYA 4Y F 5 2 Connecting the terminal DC 13 5 16V MAIN DISPLAY Connect the terminal to MAIN DISPLAY connector ...

Страница 10: ... adapter to DC connector located at the back of the device Connect the power adapter to the mains 1 2 3 Place the device at the workstation wait until it reaches room temperature up to 12 h DC 13 5 16V To switch the device on press ON OFF key Confirm or cancel the start of the automatic adjustment process 6 2 Switching the balance on Automatic adjustment Automatic adjustment ...

Страница 11: ...lance levelling for models with automatic levelling system only Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 000000 100 Log in Leveling Levelling If your balance features an automatic levelling system it will launch automatically upon turning the device on To initiate the levelling manually follow these steps ...

Страница 12: ...he arows shows how to move the balance foots to level the balance Balance has been levelled To close the levelling window press button 6 3 2 Balance levelling for models with semi automatic levelling only Your balance is ready to use Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 000000 100 Log in Leveling Levelling Leveling Leveling ...

Страница 13: ...programmable button Selecting working mode programmable button Proximity sensor Internal adjustment programmable button SETUP function button Editable quick access toolbar Configurable additional information field Weighing result window Status bar Process information field Working modes list Levelling icon balance level state Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Pack...

Страница 14: ...Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 000000 100 Log in Completed Automatic adjustment Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000129 g Packaging 0 000129 100 SETUP Log in Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000129 g Packaging 100 SETUP Log in Supplementary unit Weighing Tare Gross 0 000000 g 0 Home 0 231185 g Packaging 0 231185 1...

Страница 15: ...cal ti Newton N Baht baht Tola tola Mesghal msg User unit 1 User unit 2 8 5 Working modes settings 3 1 2 Press selected button to view the list of available options Press the icon of the current working mode to display the list of available working modes Press information field to access current working mode options Weighing 0 Home Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging 0 00...

Страница 16: ...ers button Users list is displayed select Admin option You have logged in as the Administrator Press Operators button Supplementary unit Weighing Tare Gross 0 000000 g 0 Home 0 000000 g Packaging 0 000000 100 Log in Log in Log out 1 2 Admin Operators 2 Admin Enter password Supplementary unit Weighing Admin Tare Gross 0 000000 g 0 Home 0 000000 g Packaging 0 000000 100 Weighing 0 Home Supplementary...

Страница 17: ...Password Name ad Surname Acces level User Account active Yes 3 4 5 6 Edit record 1 Name John Smith Name Name John Smith 1 2 Code Password Name ad Surname Acces level Operator Account active Yes 3 4 5 6 Edit record Code Enter user ID Password Enter user password First and last name Enter user s first and last name Access levels Set respective access level user advanced admin Account status active o...

Страница 18: ...ght or left Press information field to access current working mode options Select function that is to be assigned to the choosen sensor Press Buttons button Admin Weighing 0 Home Supplementary unit Tare Gross 0 231185 g 0 000000 g Packaging 0 000000 100 Log in Supplementary unit Tare Gross 0 000000 g 0 000000 g Packaging Weighing Printouts Profile Settings Buttons Information Buttons Soft key 7 Ta...

Страница 19: ...10 PERIPHERAL DEVICES CONNECTORS DB15 Stack light Printer Barcode scanner PLC controller RFID reader THB ambient conditions sensor Wi Fi is a registered trademark of Wi Fi Alliance ...

Страница 20: ...quid Dry sample leftovers can be removed using either brush or handheld vacuum cleaner Clean components can be dried using soft cloth or dust free paper towel with this the remaining moist will be absorbed Install all the components providing they are completely dry Use soft cloth made of either natural or synthetic fiber exclusively Avoid using cloth made of stiff hard fabric this could cause scr...

Страница 21: ... Lift the lid of microbalance weighing chamber Unscrew the draft shield s sleeve counterclockwise and remove it from the weighing chamber Use your finger to press the base of the ring assembly in order to tilt the top edge Grab the top edge and remove the ring assembly through the upper hole of the weighing chamber Using the tweezers carefully remove the weighing pan from the weighing chamber Inst...

Страница 22: ...lastic fastener from the weighing chamber using tweezers Press the weighing chamber clamp While pressing the clamp grab the chamber move it towards you and up After cleaning the weighing chamber elements they must be assembled in the reverse order ...

Страница 23: ......

Страница 24: ...www radwag com ...

Отзывы: