Performing Hardware Maintenance | 10
RADVISION | Maintenance Guide for SCOPIA Elite 5200 Series MCU Version 7.7
P/N 61546-00011
•
An antistatic wrist strap
•
A PSU. To order, contact your local RADVISION representative using the reference listed in
this table.
Table 1-5
Replacement power supply for SCOPIA Elite 5200 Series MCU
Procedure
Step 1
Verify that the redundant PSU switch is turned off.
Step 2
If you perform this procedure for the first time, turn off the MCU.
Step 3
Remove the PSU cover (see
):
a.
Insert the slot head screwdriver into the opening on the left side of the PSU cover and gently
push sideways.
Figure 1-7
Removing the PSU cover
b.
Insert the slot head screwdriver into the opening on the right side of the PSU cover and gently
push sideways.
c.
Repeat steps a and b in turn until the PSU cover is released from its clips.
Step 4
Locate the cover of the PSU compartment which covers the PSU empty slot (see
).
Note:
Set the cover of the PSU compartment aside for use as a spare part.
Name
Part number
SCOPIA Elite 5200 Series MCU AC Power Supply
55546-00613