![RadonTec ALPHAEX 150 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/radontec/alphaex-150/alphaex-150_manual_780758023.webp)
23
Manual
–
RadonTec AlphaEx 150/ 200/ 250
Connection example with motor overheating protection
QF: Circuit breaker (not included in the scope of delivery)
Х1: Terminal strip
4.
Terminals TW1 and TW2 are the electrical leads of the
normally closed contact of the motor overheating
protection
5.
Connect this contact in series to the circuit of the KM1
magnetic starter, which starts the motor after the S1
button is pressed.
6.
In case of motor overheating, the contact is
disconnected, the winding of the motor starter is
switched off and the motor is stopped.