IN065 Rev C                                                                                                                                        Page 8 of  8 

 

   

 
 

IMPORTANT INSTRUCTIONS TO INSTALLER 

 

Inspect the GP/XP/XR/SF Series Fan for shipping damage within 15 days of receipt. Notify 

RadonAway of any damages immediately

. Radonaway is not responsible for damages incurred 

during shipping. However, for your benefit, Radonaway does insure shipments. 
 
There are no user serviceable parts inside the fan. 

Do not attempt to open. 

Return unit to factory 

for service. 
 

Install the GP/XP/XR/SF Series Fan in accordance with all EPA standard practices, and state 

and local building codes and state regulations. 

 

 

WARRANT Y 

 

Subject  to any  applicable c ons um er  protection legislation,  RadonAway  warrants that  the  GPX01/XP/XR/R P/SF Series F an  (the “Fan”) will be  free 
from defects i n  materials  and workm ans hip  for a period of   90 days  from the  date of  purc has e  (the “W arranty  Term”).   

 

RadonAway  will repl ac e any F an  which fails  due to  defec ts  in materials  or  workm anship.   The F an  must  be  returned  (at Owner’s c os t)  t o  t he 
RadonAway factory . Any Fan returned to the factory will be dis carded unless  the Ow ner provides specific  instruc tions along with the Fan when it is  
ret urned regardless  of  whether or not the  Fan is  actually  replaced under this  warrant y. Proof of  purc has e  must be supplied  upon request  for 
serv ice under this Warranty. 
 
This W arranty  is c ontingent  on  installation of the F an  in accordance with  the ins tructions  provi ded.   This  Warranty  does  not  apply w here any 
repairs or alt erations  hav e been  made  or att em pted by  others ,  or if t he  unit  has  been abused or mis us ed.   Warranty does not  c ov er  damage  in 
shipm ent unles s t he damage  is due to  the negligence  of  R adonAway.   
 

5  YEAR  EXT EN DED W ARRANT Y W IT H PROFESSIONAL  IN ST ALLATION . 

 
RadonAway  will ext end  the Warranty T erm  of  the f an  to 5  years  f rom  date of  manufacture if  the  Fan is  ins talled  in a profess ionally des igned and 
profess ionally installed radon sys tem or ins talled as a replacement fan in a prof es sionally des igned and profess ionally installed radon  sys tem. 
Proof  of purc has e and/or proof of profes sional ins tallation may be required for service under t his  warranty. Outside the Continental United States 
and C anada the  ex tended W arranty T erm  is  lim ited to  one  (1)  year  from  the date of manufacture. 
 
RadonAway  is not res pons ible f or installation,  rem ov al  or delivery c osts  assoc iated with this W arranty.   

  

EXCEPT AS STATED ABOVE, THE GPx01/XP/XR/RP/SF SERIES FANS ARE PROVIDED WITHOUT 
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, 
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

 

IN NO EVENT SHALL RADONAWAY BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, 
OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR RELATING TO, THE FAN OR THE 
PERFORMANCE THEREOF.  RADONAWAY’S AGGREGATE LIABILITY HEREUNDER SHALL NOT IN 
ANY EVENT EXCEED THE AMOUNT OF THE PURCHASE PRICE OF SAID PRODUCT.  THE SOLE AND 
EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE THE REPAIR OR REPLACEMENT OF THE 
PRODUCT, TO THE EXTENT THE SAME DOES NOT MEET WITH RADONAWAY’S WARRANTY AS 
PROVIDED ABOVE.

 

 

For service under this Warranty, contact RadonAway for a Return Material Authorization (RMA) number and shipping 

information.  No returns can be accepted without an RMA.  If factory return is required, the customer assumes all shipping 

cost to and from factory. 

 

RadonAway  

3 Saber Way  

Ward Hill, MA 01835 
TEL. (978) 521-3703 

FAX (978) 521-3964 

 

Record the following information for your records: 
 

Serial 

No.       

Purchase 

Date 

    

 

 
 

 

Содержание SF180

Страница 1: ...The World s Leading Radon Fan Manufaturer SF180 Installation Instructions RadonAway 3 Saber Way Ward Hill MA 01835 www radonaway com P N IN065 REV C 2 12 ...

Страница 2: ...ical Covers Return unit to the factory for service Note An Electrical Switch Box may be installed under the removeable bottom right corner cover 6 All wiring must be performed in accordance with the National Fire Protection Association s NFPA National Electrical Code Standard 70 current edition for all commercial and industrial work and state and local building codes All wiring must be performed b...

Страница 3: ... the building occupants The velocity of the outgoing air should be considered in the overall system design In some cases the rushing sound of the outlet air may be disturbing In these instances the use of a RadonAway Exhaust Muffler is recommended 1 4 GROUND WATER In the event that a temporary high water table results in water at or above slab level water may be drawn into the riser pipes thus blo...

Страница 4: ...let ducting or where the outlet ducting is likely to produce large amounts of condensation because of high soil moisture or outlet duct material Schedule 20 piping and other thin walled plastic ducting and Aluminum downspout will normally produce much more condensation than Schedule 40 piping which is prefered 1 7 SYSTEM ON INDICATOR A properly designed system should incorporate a System On Indica...

Страница 5: ...cation The SF Series Fan is intended be mounted directly on the system piping There is no mounting bracket available for this unit In addition to the inlet and outlet pipe mounts a single vibration mount is provided at the bottom right hand corner of the inner housing underneath the removeable corner cover the vibration mount may be screwed directly to the house siding ...

Страница 6: ...ctions See Section 1 8 Fan Wire Connection Green Ground Black AC Hot White AC Common 2 4 VENT MUFFLER optional Install the muffler assembly in the selected location in the outlet ducting Solvent weld all connections The muffler is normally installed at the end of the vent pipe 2 5 OPERATION CHECKS _____ Verify all connections are tight and leak free _____ Insure the SF Series Fan and all ducting i...

Страница 7: ...1 watts SF180 1 7 W C Reduce by 10 for High Temperature Operation Reduce by 4 per 1000 feet of altitude Size Weight Inlet Outlet SF180 17 5H x16W x6 5D 13 1 lbs 4 5 OD 4 0 PVC Sched 40 size compatible Recommended ducting 3 or 4 SF180 Schedule 20 40 PVC Pipe Sch 40 prefered Mounting Mount on the duct pipe Storage temperature range 32 100 degrees F Normal operating temperature range 20 120 degrees F...

Страница 8: ...donAway 5 YEAR EXTENDED W ARRANTY W ITH PROFESSIONAL INSTALLATION RadonAway will extend the Warranty Term of the fan to 5 years from date of manufacture if the Fan is installed in a professionally designed and professionally installed radon system or installed as a replacement fan in a professionally designed and professionally installed radon system Proof of purchase and or proof of professional ...

Отзывы: