1.7  CONDENSATION & DRAINAGE

Condensation is formed in the piping of a mitigation system when the air in the piping is chilled below its dew point. 
This can occur at points where the system piping goes through unheated space such as an attic, garage or outside. 
The system design must provide a means for water to drain back to a slab hole to remove the condensation. The RP, 
GP and XP Series Fan MUST be mounted vertically plumb and level, with the outlet pointing up for proper drainage 
through the fan. Avoid mounting the fan in any orientation that will allow water to accumulate inside the fan housing. 
The RP, GP and XP Series Fans are NOT suitable for underground burial.

For RP, GP and XP Series Fan piping, the following table provides the minimum recommended pipe diameter and 
pitch under several system conditions.

See p. 7 for detailed specifications.

Pipe

Diameter

Minimum Rise per Ft of Run*

@25 CFM

@50 CFM

@100 CFM

4”

1/8”

1/4”

3/8”

3”

1/4”

3/8”

1 1/2”

1.8 SYSTEM MONITOR & LABEL

A System Monitor, such as a manometer (P/N 50017) or audible alarm (P/N 28001-2, 28001-4 or 28421), is 
required to notify the occupants of a fan system malfunction. A System Label (provided with Manometer P/N 50017) 
with instructions for contacting the installing contractor for service and identifying the necessity for regular radon tests 
to be conducted by the building occupants must be conspicuously placed in a location where the occupants frequent 
and can see the label.

1.9  ELECTRICAL WIRING

The RP, GP and XP Series Fans operate on standard 120V, 60Hz AC. All wiring must be performed in accordance 
with National Fire Protection (NFPA) National Electrical Code, Standard #70, current edition, for all commercial 
and industrial work, and state and local building codes. All wiring must be performed by a qualified and licensed 
electrician. Outdoor installations require the use of a UL Listed watertight conduit. Ensure that all exterior electrical 
boxes are outdoor rated and properly sealed to prevent water penetration into the box. A means, such as a weep hole, 
is recommended to drain the box. 

1.10 SPEED CONTROLS

The RP, GP and XP Series Fans are rated for use with electronic speed controls; however, speed controls are generally 
not recommended. If used, the recommended speed control is Pass & Seymour Solid State Speed Control (Cat. No. 
94601-1).

RU N

R

ISE

120 VAC

Common

Ground

Capacitor

White

Black

Brn

Brn/Wht

Green

Motor

RP, GP, XP Series Fan Wiring Diagram

Содержание RP140

Страница 1: ...IN095 Rev B 0718 1 3 Saber Way Ward Hill MA 01835 radonaway com RP GP XP Pro Series Installation Instructions...

Страница 2: ...m this non operational storage 6 WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you hav...

Страница 3: ...stallation For bathroom and general ventilation applications at least 8 feet of insulated flexible duct shall be installed between the exhaust or supply grille s and the fan s RP GP and XP Series Fans...

Страница 4: ...o notify the occupants of a fan system malfunction A System Label provided with Manometer P N 50017 with instructions for contacting the installing contractor for service and identifying the necessity...

Страница 5: ...et and mounting surface for vibration isolation 2 3 SYSTEM PIPING Complete piping run using flexible couplings as a means of disconnect for servicing the unit and for vibration isolation As the fan is...

Страница 6: ...0 251 209 157 117 70 26 RP265 375 330 282 238 204 170 140 108 70 RP380 531 490 415 340 268 200 139 84 41 Model Size Weight Inlet Outlet L 2 RP140 8 5 H x 9 7 Dia 5 5 lbs 4 5 OD 4 0 PVC Sched 40 size c...

Страница 7: ...1000 ft of altitude GP Series Product Specifications Model Recommended Duct PVC Pipe Mounting Thermal Cutout Insulation Class RP140 3 or 4 Schedule 20 40 PVC Mount on the duct pipe or with optional m...

Страница 8: ...ranty Proof of purchase must be supplied upon request for service under this Warranty 5 YEAR EXTENDED WARRANTY WITH PROFESSIONAL INSTALLATION RadonAway will extend the Warranty Term of the fan to 60 m...

Отзывы: