![RADLEY 1280-008 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/radley/1280-008/1280-008_owners-manual_780645016.webp)
15
TROUBLESHOOTING
Trouble
Possible Cause
Remedy
Tool will not turn on
ON/OFF button does not work
Check that the button is properly
engaging the electronic assembly
Battery no power
To charge the battery with the supplied
charger then turn the tool after the
battery is fully charged
Faulty electronic assembly
Replace the entire electronic assembly
Can not adjust the
speed
Speed control button loose
or faulty electronic assembly
Replace the entire electronic assembly
Shaft on the rotary
tool will not lock
Faulty shaft lock button
If the shaft rotates even when the
shaft lock is pressed, the button will
need be replaced
Tool is overheating
Ventilation slots are covered
Clean the vents, ensure that they are not
covered by dust, dirt etc.
Overuse or over pressure
onto rotary tool
During use, make sure to pause
occasionally to reduce temperature
(especially working at low speed
condition). Apply proper pressure when
using tool according to its rating
Bits or collet no longer
tighten/ loosen
Collet flexibility
Collet nut worn out
Bits shank worn out
Replace with new collet,
collet nut or bits
Tool makes a
squealing and
whistling sound
Faulty bearing assembly or
fan is broken.
Entire armature and bearing assembly
need to be replaced immediately.