1.  IMPORTANT SAFETY INFORMATION 
 

 

Installation 

Check that the supply voltage given to the instrument is         
as specified on the terminals of the instrument. To avoid 
shock hazard prevent live parts being touched and follow 
wiring diagram and specifications. 
 

 

Warranty 

Radix Electrosystems Pvt. Ltd. warrants this product to be 
free of defects in workmanship and materials for one year 
from the date of purchase.  
 
1.  Defects in workmanship and materials will be 

serviced free of charge during the warranty period. 
Labour required for rectifying the defects is also 
covered by this warranty. Any further claims are 
excluded. 

 
2.   Warranty servicing does not extend the period of 

warranty for the entire instrument or for the parts that 
have been replaced. 

 
3. 

From the warranty are excluded : 

 

 

a)  all damage caused by improper handling, e.g. 

non-observance of the operating instructions, 
subjecting the product to excessive heat, 
moisture, corrosion, etc. 

 

b)  damage caused by the intervention of the buyer 

or by unauthorised third parties 

 

 

 

c)  transport damage from the manufacturer to the 

dealer or user or on the way to servicing  

 

d)  parts subject to normal wear, e.g. relays. 

 

 
4.  Any liability for direct or indirect consequential 

damages caused by the instrument is excluded, even 
if the defect of the instrument is covered by the 
warranty.  

 

Radix liability for any breach of this agreement shall 
not exceed the purchase price paid. 

 
5.   Any further claims, based on any title, are excluded.

 

6.   In case repair service is required under this factory 

warranty, please send the instrument, indicating the 
exact address of the sender and defect, carefully 
packed, postage paid, to : Radix Microsystems, B-1, 
2nd Floor, Ghanshyam Indl. Estate, Off  Veera Desai 
Road, Andheri (West), Mumbai - 400 053. 

 

2.  INTRODUCTION                                                         

 

T25 is a microcontroller based 2 digit user 
programmable timer. 

The operator can view and set the parameters 
through LED display and the two keys on the front 
panel. 

The settime is set using keys and display. 

The instrument has two relay outputs. 

3. FRONT 

PANEL 

 

 

M

S

Fw

t

x10

T

2

5

Rv

1

3

2

6

4

5

Fig1

4.  KEY FUNCTIONS AND PARAMETER 

PROGRAMMING 

Key Function 

In program mode this key is used to change 
the value of the selected parameter. 
a)  In program mode this key is used to 

change the value of the selected 
parameter. 

b)  In run (normal) mode it is used as a start & 

stop key.  

&

In run mode press & hold these keys together 
for 3 seconds to enter the program mode 

NO KEY 

a)  In program mode display will toggle 

between the parameter name & its value. 
If no key is pressed for 5 seconds display 
will toggle between the next parameter 
name and its value for 5 seconds. After all 
parameters are over, the instrument 
automatically exits the program mode and 
enters run (normal) mode 

b)  In setpoint mode display will toggle 

between SP & its value and after 5 
seconds the instrument automatically exits 
the setpoint mode and enters run (normal) 
mode. 

5. CONNECTION 

DIAGRAM 

 

t = Timing on  

M = Minutes  

S = Seconds  

Fw = Forward                                    

Rv = Reverse 

X10 = multiplied  

 

by 10 

 

A1

C2

24 ~ 265 V 

AC/DC 

A2

~

~